formatdomain.html.in 306.8 KB
Newer Older
1 2 3
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
<html xmlns="http://www.w3.org/1999/xhtml">
4 5 6
  <body>
    <h1>Domain XML format</h1>

D
Daniel P. Berrange 已提交
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
    <ul id="toc"></ul>

    <p>
      This section describes the XML format used to represent domains, there are
      variations on the format based on the kind of domains run and the options
      used to launch them. For hypervisor specific details consult the
      <a href="drivers.html">driver docs</a>
    </p>


    <h2><a name="elements">Element and attribute overview</a></h2>

    <p>
      The root element required for all virtual machines is
      named <code>domain</code>. It has two attributes, the
      <code>type</code> specifies the hypervisor used for running
      the domain. The allowed values are driver specific, but
      include "xen", "kvm", "qemu", "lxc" and "kqemu". The
      second attribute is <code>id</code> which is a unique
      integer identifier for the running guest machine. Inactive
      machines have no id value.
    </p>


    <h3><a name="elementsMetadata">General metadata</a></h3>

33 34 35 36
<pre>
&lt;domain type='xen' id='3'&gt;
  &lt;name&gt;fv0&lt;/name&gt;
  &lt;uuid&gt;4dea22b31d52d8f32516782e98ab3fa0&lt;/uuid&gt;
37
  &lt;title&gt;A short description - title - of the domain&lt;/title&gt;
38
  &lt;description&gt;Some human readable description&lt;/description&gt;
39 40 41 42
  &lt;metadata&gt;
    &lt;app1:foo xmlns:app1="http://app1.org/app1/"&gt;..&lt;/app1:foo&gt;
    &lt;app2:bar xmlns:app2="http://app1.org/app2/"&gt;..&lt;/app2:bar&gt;
  &lt;/metadata&gt;
43
  ...</pre>
D
Daniel P. Berrange 已提交
44 45 46 47

    <dl>
      <dt><code>name</code></dt>
      <dd>The content of the <code>name</code> element provides
M
Matthew Booth 已提交
48 49 50 51 52
        a short name for the virtual machine. This name should
        consist only of alpha-numeric characters and is required
        to be unique within the scope of a single host. It is
        often used to form the filename for storing the persistent
        configuration file. <span class="since">Since 0.0.1</span></dd>
D
Daniel P. Berrange 已提交
53 54
      <dt><code>uuid</code></dt>
      <dd>The content of the <code>uuid</code> element provides
M
Matthew Booth 已提交
55
        a globally unique identifier for the virtual machine.
E
Eric Blake 已提交
56 57
        The format must be RFC 4122 compliant,
        eg <code>3e3fce45-4f53-4fa7-bb32-11f34168b82b</code>.
M
Matthew Booth 已提交
58
        If omitted when defining/creating a new machine, a random
59 60 61 62
        UUID is generated. It is also possible to provide the UUID
        via a <a href="#elementsSysinfo"><code>sysinfo</code></a>
        specification. <span class="since">Since 0.0.1, sysinfo
        since 0.8.7</span></dd>
63

64 65 66 67 68
      <dt><code>title</code></dt>
      <dd>The optional element <code>title</code> provides space for a
        short description of the domain. The title should not contain
        any newlines. <span class="since">Since 0.9.10</span>.</dd>

69 70
      <dt><code>description</code></dt>
      <dd>The content of the <code>description</code> element provides a
71 72 73 74 75 76 77 78 79 80 81 82
        human readable description of the virtual machine. This data is not
        used by libvirt in any way, it can contain any information the user
        wants. <span class="since">Since 0.7.2</span></dd>

      <dt><code>metadata</code></dt>
      <dd>The <code>metadata</code> node can be used by applications
        to store custom metadata in the form of XML
        nodes/trees. Applications must use custom namespaces on their
        XML nodes/trees, with only one top-level element per namespace
        (if the application needs structure, they should have
        sub-elements to their namespace
        element). <span class="since">Since 0.9.10</span></dd>
83
   </dl>
D
Daniel P. Berrange 已提交
84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100

    <h3><a name="elementsOS">Operating system booting</a></h3>

    <p>
      There are a number of different ways to boot virtual machines
      each with their own pros and cons.
    </p>

    <h4><a name="elementsOSBIOS">BIOS bootloader</a></h4>

    <p>
      Booting via the BIOS is available for hypervisors supporting
      full virtualization. In this case the BIOS has a boot order
      priority (floppy, harddisk, cdrom, network) determining where
      to obtain/find the boot image.
    </p>

101
<pre>
102 103 104 105 106 107 108 109 110 111 112 113
...
&lt;os&gt;
  &lt;type&gt;hvm&lt;/type&gt;
  &lt;loader readonly='yes' secure='no' type='rom'&gt;/usr/lib/xen/boot/hvmloader&lt;/loader&gt;
  &lt;nvram template='/usr/share/OVMF/OVMF_VARS.fd'&gt;/var/lib/libvirt/nvram/guest_VARS.fd&lt;/nvram&gt;
  &lt;boot dev='hd'/&gt;
  &lt;boot dev='cdrom'/&gt;
  &lt;bootmenu enable='yes' timeout='3000'/&gt;
  &lt;smbios mode='sysinfo'/&gt;
  &lt;bios useserial='yes' rebootTimeout='0'/&gt;
&lt;/os&gt;
...</pre>
D
Daniel P. Berrange 已提交
114 115 116 117

    <dl>
      <dt><code>type</code></dt>
      <dd>The content of the <code>type</code> element specifies the
M
Matthew Booth 已提交
118 119 120 121 122
        type of operating system to be booted in the virtual machine.
        <code>hvm</code> indicates that the OS is one designed to run
        on bare metal, so requires full virtualization. <code>linux</code>
        (badly named!) refers to an OS that supports the Xen 3 hypervisor
        guest ABI. There are also two optional attributes, <code>arch</code>
E
Eric Blake 已提交
123 124 125 126 127
        specifying the CPU architecture to virtualization,
        and <code>machine</code> referring to the machine
        type. The <a href="formatcaps.html">Capabilities XML</a>
        provides details on allowed values for
        these. <span class="since">Since 0.0.1</span></dd>
D
Daniel P. Berrange 已提交
128
      <dt><code>loader</code></dt>
129 130
      <dd>The optional <code>loader</code> tag refers to a firmware blob,
        which is specified by absolute path,
131 132 133
        used to assist the domain creation process. It is used by Xen
        fully virtualized domains as well as setting the QEMU BIOS file
        path for QEMU/KVM domains. <span class="since">Xen since 0.1.0,
134 135 136 137 138 139 140 141 142
        QEMU/KVM since 0.9.12</span> Then, <span class="since">since
        1.2.8</span> it's possible for the element to have two
        optional attributes: <code>readonly</code> (accepted values are
        <code>yes</code> and <code>no</code>) to reflect the fact that the
        image should be writable or read-only. The second attribute
        <code>type</code> accepts values <code>rom</code> and
        <code>pflash</code>. It tells the hypervisor where in the guest
        memory the file should be mapped.  For instance, if the loader
        path points to an UEFI image, <code>type</code> should be
143 144 145 146
        <code>pflash</code>. Moreover, some firmwares may
        implement the Secure boot feature. Attribute
        <code>secure</code> can be used then to control it.
        <span class="since">Since 2.1.0</span></dd>
147 148
      <dt><code>nvram</code></dt>
      <dd>Some UEFI firmwares may want to use a non-volatile memory to store
149 150 151 152
        some variables. In the host, this is represented as a file and the
        absolute path to the file is stored in this element. Moreover, when the
        domain is started up libvirt copies so called master NVRAM store file
        defined in <code>qemu.conf</code>. If needed, the <code>template</code>
153
        attribute can be used to per domain override map of master NVRAM stores
154 155 156 157
        from the config file. Note, that for transient domains if the NVRAM file
        has been created by libvirt it is left behind and it is management
        application's responsibility to save and remove file (if needed to be
        persistent). <span class="since">Since 1.2.8</span></dd>
D
Daniel P. Berrange 已提交
158 159
      <dt><code>boot</code></dt>
      <dd>The <code>dev</code> attribute takes one of the values "fd", "hd",
M
Matthew Booth 已提交
160 161
        "cdrom" or "network" and is used to specify the next boot device
        to consider. The <code>boot</code> element can be repeated multiple
162 163 164 165 166 167 168 169 170 171 172 173
        times to setup a priority list of boot devices to try in turn.
        Multiple devices of the same type are sorted according to their
        targets while preserving the order of buses. After defining the
        domain, its XML configuration returned by libvirt (through
        virDomainGetXMLDesc) lists devices in the sorted order. Once sorted,
        the first device is marked as bootable. Thus, e.g., a domain
        configured to boot from "hd" with vdb, hda, vda, and hdc disks
        assigned to it will boot from vda (the sorted list is vda, vdb, hda,
        hdc). Similar domain with hdc, vda, vdb, and hda disks will boot from
        hda (sorted disks are: hda, hdc, vda, vdb). It can be tricky to
        configure in the desired way, which is why per-device boot elements
        (see <a href="#elementsDisks">disks</a>,
174
        <a href="#elementsNICS">network interfaces</a>, and
175
        <a href="#elementsHostDev">USB and PCI devices</a> sections below) were
176 177 178 179
        introduced and they are the preferred way providing full control over
        booting order. The <code>boot</code> element and per-device boot
        elements are mutually exclusive. <span class="since">Since 0.1.3,
        per-device boot since 0.8.8</span>
D
Daniel P. Berrange 已提交
180
      </dd>
181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205
      <dt><code>smbios</code></dt>
      <dd>How to populate SMBIOS information visible in the guest.
        The <code>mode</code> attribute must be specified, and is either
        "emulate" (let the hypervisor generate all values), "host" (copy
        all of Block 0 and Block 1, except for the UUID, from the host's
        SMBIOS values;
        the <a href="html/libvirt-libvirt-host.html#virConnectGetSysinfo">
        <code>virConnectGetSysinfo</code></a> call can be
        used to see what values are copied), or "sysinfo" (use the values in
        the <a href="#elementsSysinfo">sysinfo</a> element).  If not
        specified, the hypervisor default is used. <span class="since">
        Since 0.8.7</span>
      </dd>
  </dl>
      <p>Up till here the BIOS/UEFI configuration knobs are generic enough to
      be implemented by majority (if not all) firmwares out there. However,
      from now on not every single setting makes sense to all firmwares. For
      instance, <code>rebootTimeout</code> doesn't make sense for UEFI,
      <code>useserial</code> might not be usable with a BIOS firmware that
      doesn't produce any output onto serial line, etc. Moreover, firmwares
      don't usually export their capabilities for libvirt (or users) to check.
      And the set of their capabilities can change with every new release.
      Hence users are advised to try the settings they use before relying on
      them in production.</p>
  <dl>
206 207 208 209 210
      <dt><code>bootmenu</code></dt>
      <dd> Whether or not to enable an interactive boot menu prompt on guest
      startup. The <code>enable</code> attribute can be either "yes" or "no".
      If not specified, the hypervisor default is used. <span class="since">
      Since 0.8.3</span>
211 212
      Additional attribute <code>timeout</code> takes the number of milliseconds
      the boot menu should wait until it times out.  Allowed values are numbers
213 214
      in range [0, 65535] inclusive and it is ignored unless <code>enable</code>
      is set to "yes". <span class="since">Since 1.2.8</span>
215
      </dd>
M
Michal Privoznik 已提交
216 217 218 219 220 221
      <dt><code>bios</code></dt>
      <dd>This element has attribute <code>useserial</code> with possible
        values <code>yes</code> or <code>no</code>. It enables or disables
        Serial Graphics Adapter which allows users to see BIOS messages
        on a serial port. Therefore, one needs to have
        <a href="#elementCharSerial">serial port</a> defined.
222 223 224 225 226 227 228
        <span class="since">Since 0.9.4</span>.
        <span class="since">Since 0.10.2 (QEMU only)</span> there is
        another attribute, <code>rebootTimeout</code> that controls
        whether and after how long the guest should start booting
        again in case the boot fails (according to BIOS). The value is
        in milliseconds with maximum of <code>65535</code> and special
        value <code>-1</code> disables the reboot.
229
      </dd>
D
Daniel P. Berrange 已提交
230 231 232 233 234 235 236
    </dl>

    <h4><a name="elementsOSBootloader">Host bootloader</a></h4>

    <p>
      Hypervisors employing paravirtualization do not usually emulate
      a BIOS, and instead the host is responsible to kicking off the
A
Atsushi SAKAI 已提交
237
      operating system boot. This may use a pseudo-bootloader in the
D
Daniel P. Berrange 已提交
238
      host to provide an interface to choose a kernel for the guest.
239 240 241
      An example is <code>pygrub</code> with Xen. The Bhyve hypervisor
      also uses a host bootloader, either <code>bhyveload</code> or
      <code>grub-bhyve</code>.
D
Daniel P. Berrange 已提交
242 243
    </p>

244
<pre>
245 246 247 248
...
&lt;bootloader&gt;/usr/bin/pygrub&lt;/bootloader&gt;
&lt;bootloader_args&gt;--append single&lt;/bootloader_args&gt;
...</pre>
D
Daniel P. Berrange 已提交
249 250 251 252

    <dl>
      <dt><code>bootloader</code></dt>
      <dd>The content of the <code>bootloader</code> element provides
M
Matthew Booth 已提交
253 254 255 256
        a fully qualified path to the bootloader executable in the
        host OS. This bootloader will be run to choose which kernel
        to boot. The required output of the bootloader is dependent
        on the hypervisor in use. <span class="since">Since 0.1.0</span></dd>
D
Daniel P. Berrange 已提交
257 258
      <dt><code>bootloader_args</code></dt>
      <dd>The optional <code>bootloader_args</code> element allows
M
Matthew Booth 已提交
259 260 261
        command line arguments to be passed to the bootloader.
        <span class="since">Since 0.2.3</span>
        </dd>
D
Daniel P. Berrange 已提交
262 263 264 265 266 267 268 269 270 271 272 273

    </dl>

    <h4><a name="elementsOSKernel">Direct kernel boot</a></h4>

    <p>
      When installing a new guest OS it is often useful to boot directly
      from a kernel and initrd stored in the host OS, allowing command
      line arguments to be passed directly to the installer. This capability
      is usually available for both para and full virtualized guests.
    </p>

274
<pre>
275 276 277 278 279 280 281 282 283 284 285 286 287
...
&lt;os&gt;
  &lt;type&gt;hvm&lt;/type&gt;
  &lt;loader&gt;/usr/lib/xen/boot/hvmloader&lt;/loader&gt;
  &lt;kernel&gt;/root/f8-i386-vmlinuz&lt;/kernel&gt;
  &lt;initrd&gt;/root/f8-i386-initrd&lt;/initrd&gt;
  &lt;cmdline&gt;console=ttyS0 ks=http://example.com/f8-i386/os/&lt;/cmdline&gt;
  &lt;dtb&gt;/root/ppc.dtb&lt;/dtb&gt;
  &lt;acpi&gt;
    &lt;table type='slic'&gt;/path/to/slic.dat&lt;/table&gt;
  &lt;/acpi&gt;
&lt;/os&gt;
...</pre>
D
Daniel P. Berrange 已提交
288 289 290 291

    <dl>
      <dt><code>type</code></dt>
      <dd>This element has the same semantics as described earlier in the
M
Matthew Booth 已提交
292
        <a href="#elementsOSBIOS">BIOS boot section</a></dd>
D
Daniel Veillard 已提交
293
      <dt><code>loader</code></dt>
D
Daniel P. Berrange 已提交
294
      <dd>This element has the same semantics as described earlier in the
M
Matthew Booth 已提交
295
        <a href="#elementsOSBIOS">BIOS boot section</a></dd>
D
Daniel P. Berrange 已提交
296 297
      <dt><code>kernel</code></dt>
      <dd>The contents of this element specify the fully-qualified path
M
Matthew Booth 已提交
298
        to the kernel image in the host OS.</dd>
D
Daniel P. Berrange 已提交
299 300
      <dt><code>initrd</code></dt>
      <dd>The contents of this element specify the fully-qualified path
M
Matthew Booth 已提交
301
        to the (optional) ramdisk image in the host OS.</dd>
D
Daniel P. Berrange 已提交
302 303
      <dt><code>cmdline</code></dt>
      <dd>The contents of this element specify arguments to be passed to
304
        the kernel (or installer) at boot time. This is often used to
M
Matthew Booth 已提交
305 306
        specify an alternate primary console (eg serial port), or the
        installation media source / kickstart file</dd>
307 308 309 310
      <dt><code>dtb</code></dt>
      <dd>The contents of this element specify the fully-qualified path
        to the (optional) device tree binary (dtb) image in the host OS.
        <span class="since">Since 1.0.4</span></dd>
J
Ján Tomko 已提交
311 312 313 314 315
      <dt><code>acpi</code></dt>
      <dd>The <code>table</code> element contains a fully-qualified path
        to the ACPI table. The <code>type</code> attribute contains the
        ACPI table type (currently only <code>slic</code> is supported)
        <span class="since">Since 1.3.5 (QEMU only)</span></dd>
D
Daniel P. Berrange 已提交
316 317
    </dl>

318
    <h4><a name="elementsOSContainer">Container boot</a></h4>
319 320 321 322 323 324 325 326

    <p>
      When booting a domain using container based virtualization, instead
      of a kernel / boot image, a path to the init binary is required, using
      the <code>init</code> element. By default this will be launched with
      no arguments. To specify the initial argv, use the <code>initarg</code>
      element, repeated as many time as is required. The <code>cmdline</code>
      element, if set will be used to provide an equivalent to <code>/proc/cmdline</code>
C
Chen Hanxiao 已提交
327
      but will not affect init argv.
328 329 330
    </p>

    <pre>
331 332 333 334 335 336
&lt;os&gt;
  &lt;type arch='x86_64'&gt;exe&lt;/type&gt;
  &lt;init&gt;/bin/systemd&lt;/init&gt;
  &lt;initarg&gt;--unit&lt;/initarg&gt;
  &lt;initarg&gt;emergency.service&lt;/initarg&gt;
&lt;/os&gt;
337 338 339
    </pre>


340
    <p>
341 342
      If you want to enable user namespace, set the <code>idmap</code> element.
      The <code>uid</code> and <code>gid</code> elements have three attributes:
343 344 345 346
    </p>

    <dl>
      <dt><code>start</code></dt>
347
      <dd>First user ID in container. It must be '0'.</dd>
348
      <dt><code>target</code></dt>
349 350
      <dd>The first user ID in container will be mapped to this target user
          ID in host.</dd>
351
      <dt><code>count</code></dt>
352
      <dd>How many users in container are allowed to map to host's user.</dd>
353 354 355
    </dl>

    <pre>
356 357 358 359
&lt;idmap&gt;
  &lt;uid start='0' target='1000' count='10'/&gt;
  &lt;gid start='0' target='1000' count='10'/&gt;
&lt;/idmap&gt;
360 361 362
    </pre>


363 364 365 366 367 368 369 370 371 372 373 374
    <h3><a name="elementsSysinfo">SMBIOS System Information</a></h3>

    <p>
      Some hypervisors allow control over what system information is
      presented to the guest (for example, SMBIOS fields can be
      populated by a hypervisor and inspected via
      the <code>dmidecode</code> command in the guest).  The
      optional <code>sysinfo</code> element covers all such categories
      of information. <span class="since">Since 0.8.7</span>
    </p>

<pre>
375 376 377
...
&lt;os&gt;
  &lt;smbios mode='sysinfo'/&gt;
378
  ...
379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396
&lt;/os&gt;
&lt;sysinfo type='smbios'&gt;
  &lt;bios&gt;
    &lt;entry name='vendor'&gt;LENOVO&lt;/entry&gt;
  &lt;/bios&gt;
  &lt;system&gt;
    &lt;entry name='manufacturer'&gt;Fedora&lt;/entry&gt;
    &lt;entry name='product'&gt;Virt-Manager&lt;/entry&gt;
    &lt;entry name='version'&gt;0.9.4&lt;/entry&gt;
  &lt;/system&gt;
  &lt;baseBoard&gt;
    &lt;entry name='manufacturer'&gt;LENOVO&lt;/entry&gt;
    &lt;entry name='product'&gt;20BE0061MC&lt;/entry&gt;
    &lt;entry name='version'&gt;0B98401 Pro&lt;/entry&gt;
    &lt;entry name='serial'&gt;W1KS427111E&lt;/entry&gt;
  &lt;/baseBoard&gt;
&lt;/sysinfo&gt;
...</pre>
397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416

    <p>
      The <code>sysinfo</code> element has a mandatory
      attribute <code>type</code> that determine the layout of
      sub-elements, with supported values of:
    </p>

    <dl>
      <dt><code>smbios</code></dt>
      <dd>Sub-elements call out specific SMBIOS values, which will
      affect the guest if used in conjunction with
      the <code>smbios</code> sub-element of
      the <a href="#elementsOS"><code>os</code></a> element.  Each
      sub-element of <code>sysinfo</code> names a SMBIOS block, and
      within those elements can be a list of <code>entry</code>
      elements that describe a field within the block.  The following
      blocks and entries are recognized:
        <dl>
          <dt><code>bios</code></dt>
          <dd>
417 418 419 420 421 422 423 424 425 426 427 428 429 430 431
            This is block 0 of SMBIOS, with entry names drawn from:
            <dl>
               <dt><code>vendor</code></dt>
               <dd>BIOS Vendor's Name</dd>
               <dt><code>version</code></dt>
               <dd>BIOS Version</dd>
               <dt><code>date</code></dt>
               <dd>BIOS release date. If supplied, is in either mm/dd/yy or
                   mm/dd/yyyy format. If the year portion of the string is
                   two digits, the year is assumed to be 19yy.</dd>
               <dt><code>release</code></dt>
               <dd>System BIOS Major and Minor release number values
                   concatenated together as one string separated by
                   a period, for example, 10.22.</dd>
           </dl>
432 433 434
          </dd>
          <dt><code>system</code></dt>
          <dd>
435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454
            This is block 1 of SMBIOS, with entry names drawn from:
            <dl>
                <dt><code>manufacturer</code></dt>
                <dd>Manufacturer of BIOS</dd>
                <dt><code>product</code></dt>
                <dd>Product Name</dd>
                <dt><code>version</code></dt>
                <dd>Version of the product</dd>
                <dt><code>serial</code></dt>
                <dd>Serial number</dd>
                <dt><code>uuid</code></dt>
                <dd>Universal Unique ID number. If this entry is provided
                alongside a top-level
                <a href="#elementsMetadata"><code>uuid</code></a> element,
                then the two values must match.</dd>
                <dt><code>sku</code></dt>
                <dd>SKU number to identify a particular configuration.</dd>
                <dt><code>family</code></dt>
                <dd>Identify the family a particular computer belongs to.</dd>
            </dl>
455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480
          </dd>
          <dt><code>baseBoard</code></dt>
          <dd>
            This is block 2 of SMBIOS. This element can be repeated multiple
            times to describe all the base boards; however, not all
            hypervisors necessarily support the repetition. The element can
            have the following children:
            <dl>
                <dt><code>manufacturer</code></dt>
                <dd>Manufacturer of BIOS</dd>
                <dt><code>product</code></dt>
                <dd>Product Name</dd>
                <dt><code>version</code></dt>
                <dd>Version of the product</dd>
                <dt><code>serial</code></dt>
                <dd>Serial number</dd>
                <dt><code>asset</code></dt>
                <dd>Asset tag</dd>
                <dt><code>location</code></dt>
                <dd>Location in chassis</dd>
            </dl>
            NB: Incorrectly supplied entries for the
            <code>bios</code>, <code>system</code> or <code>baseBoard</code>
            blocks will be ignored without error.  Other than <code>uuid</code>
            validation and <code>date</code> format checking, all values are
            passed as strings to the hypervisor driver.
481 482 483 484 485
          </dd>
        </dl>
      </dd>
    </dl>

486
    <h3><a name="elementsCPUAllocation">CPU Allocation</a></h3>
D
Daniel P. Berrange 已提交
487

488
<pre>
489
&lt;domain&gt;
490
  ...
O
Osier Yang 已提交
491
  &lt;vcpu placement='static' cpuset="1-4,^3,6" current="1"&gt;2&lt;/vcpu&gt;
492 493 494 495
  &lt;vcpus&gt;
    &lt;vcpu id='0' enabled='yes' hotpluggable='no' order='1'/&gt;
    &lt;vcpu id='1' enabled='no' hotpluggable='yes'/&gt;
  &lt;/vcpus&gt;
496 497 498
  ...
&lt;/domain&gt;
</pre>
D
Daniel P. Berrange 已提交
499 500 501

    <dl>
      <dt><code>vcpu</code></dt>
502
      <dd>The content of this element defines the maximum number of virtual
E
Eric Blake 已提交
503
        CPUs allocated for the guest OS, which must be between 1 and
504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547
        the maximum supported by the hypervisor.
        <dl>
         <dt><code>cpuset</code></dt>
         <dd>
           The optional attribute <code>cpuset</code> is a comma-separated
           list of physical CPU numbers that domain process and virtual CPUs
           can be pinned to by default. (NB: The pinning policy of domain
           process and virtual CPUs can be specified separately by
           <code>cputune</code>. If the attribute <code>emulatorpin</code>
           of <code>cputune</code> is specified, the <code>cpuset</code>
           specified by <code>vcpu</code> here will be ignored. Similarly,
           for virtual CPUs which have the <code>vcpupin</code> specified,
           the <code>cpuset</code> specified by <code>cpuset</code> here
           will be ignored. For virtual CPUs which don't have
           <code>vcpupin</code> specified, each will be pinned to the physical
           CPUs specified by <code>cpuset</code> here).
           Each element in that list is either a single CPU number,
           a range of CPU numbers, or a caret followed by a CPU number to
           be excluded from a previous range.
           <span class="since">Since 0.4.4</span>
         </dd>
         <dt><code>current</code></dt>
         <dd>
           The optional attribute <code>current</code> can
           be used to specify whether fewer than the maximum number of
           virtual CPUs should be enabled.
           <span class="since">Since 0.8.5</span>
         </dd>
         <dt><code>placement</code></dt>
         <dd>
           The optional attribute <code>placement</code> can be used to
           indicate the CPU placement mode for domain process. The value can
           be either "static" or "auto", but defaults to <code>placement</code>
           of <code>numatune</code> or "static" if <code>cpuset</code> is
           specified. Using "auto" indicates the domain process will be pinned
           to the advisory nodeset from querying numad and the value of
           attribute <code>cpuset</code> will be ignored if it's specified.
           If both <code>cpuset</code> and <code>placement</code> are not
           specified or if <code>placement</code> is "static", but no
           <code>cpuset</code> is specified, the domain process will be
           pinned to all the available physical CPUs.
           <span class="since">Since 0.9.11 (QEMU and KVM only)</span>
         </dd>
        </dl>
E
Eric Blake 已提交
548
      </dd>
549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566
      <dt><code>vcpus</code></dt>
      <dd>
        The vcpus element allows to control state of individual vcpus.

        The <code>id</code> attribute specifies the vCPU id as used by libvirt
        in other places such as vcpu pinning, scheduler information and NUMA
        assignment. Note that the vcpu ID as seen in the guest may differ from
        libvirt ID in certain cases. Valid IDs are from 0 to the maximum vcpu
        count as set by the <code>vcpu</code> element minus 1.

        The <code>enabled</code> attribute allows to control the state of the
        vcpu. Valid values are <code>yes</code> and <code>no</code>.

        <code>hotpluggable</code> controls whether given vcpu can be hotplugged
        and hotunplugged in cases when the cpu is enabled at boot. Note that
        all disabled vcpus must be hotpluggable. Valid values are
        <code>yes</code> and <code>no</code>.

567 568
        <code>order</code> allows to specify the order to add the online vcpus.
        For hypervisors/platforms that require to insert multiple vcpus at once
569 570
        the order may be be duplicated accross all vcpus that need to be
        enabled at once. Specifying order is not necessary, vcpus are then
571
        added in an arbitrary order. If order info is used, it must be used for
572 573
        all online vcpus. Hypervisors may clear or update ordering information
        during certain operations to assure valid configuration.
574 575 576 577 578 579 580 581 582 583 584

        Note that hypervisors may create hotpluggable vcpus differently from
        boot vcpus thus special initialization may be necessary.

        Hypervisors may require that vcpus enabled on boot which are not
        hotpluggable are clustered at the beginning starting with ID 0. It may
        be also required that vcpu 0 is always present and non-hotpluggable.

        Note that providing state for individual cpus may be necessary to enable
        support of addressable vCPU hotplug and this feature may not be
        supported by all hypervisors.
585 586 587 588 589

        For QEMU the following conditions are required. Vcpu 0 needs to be
        enabled and non-hotpluggable. On PPC64 along with it vcpus that are in
        the same core need to be enabled as well. All non-hotpluggable cpus
        present at boot need to be grouped after vcpu 0.
590 591
        <span class="since">Since 2.2.0 (QEMU only)</span>
      </dd>
592 593
    </dl>

594 595 596 597 598 599 600 601 602 603 604 605 606 607
    <h3><a name="elementsIOThreadsAllocation">IOThreads Allocation</a></h3>
      <p>
        IOThreads are dedicated event loop threads for supported disk
        devices to perform block I/O requests in order to improve
        scalability especially on an SMP host/guest with many LUNs.
        <span class="since">Since 1.2.8 (QEMU only)</span>
      </p>

<pre>
&lt;domain&gt;
  ...
  &lt;iothreads&gt;4&lt;/iothreads&gt;
  ...
&lt;/domain&gt;
608 609 610 611 612 613 614 615 616 617 618 619
</pre>
<pre>
&lt;domain&gt;
  ...
  &lt;iothreadids&gt;
    &lt;iothread id="2"/&gt;
    &lt;iothread id="4"/&gt;
    &lt;iothread id="6"/&gt;
    &lt;iothread id="8"/&gt;
  &lt;/iothreadids&gt;
  ...
&lt;/domain&gt;
620 621 622 623 624 625 626
</pre>

    <dl>
      <dt><code>iothreads</code></dt>
      <dd>
        The content of this optional element defines the number
        of IOThreads to be assigned to the domain for use by
627
        supported target storage devices. There
628 629
        should be only 1 or 2 IOThreads per host CPU. There may be more
        than one supported device assigned to each IOThread.
630
        <span class="since">Since 1.2.8</span>
631
      </dd>
632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648
      <dt><code>iothreadids</code></dt>
      <dd>
        The optional <code>iothreadids</code> element provides the capability
        to specifically define the IOThread ID's for the domain.  By default,
        IOThread ID's are sequentially numbered starting from 1 through the
        number of <code>iothreads</code> defined for the domain. The
        <code>id</code> attribute is used to define the IOThread ID. The
        <code>id</code> attribute must be a positive integer greater than 0.
        If there are less <code>iothreadids</code> defined than
        <code>iothreads</code> defined for the domain, then libvirt will
        sequentially fill <code>iothreadids</code> starting at 1 avoiding
        any predefined <code>id</code>. If there are more
        <code>iothreadids</code> defined than <code>iothreads</code>
        defined for the domain, then the <code>iothreads</code> value
        will be adjusted accordingly.
        <span class="since">Since 1.2.15</span>
       </dd>
649
    </dl>
650 651 652 653 654 655 656 657 658 659 660

    <h3><a name="elementsCPUTuning">CPU Tuning</a></h3>

<pre>
&lt;domain&gt;
  ...
  &lt;cputune&gt;
    &lt;vcpupin vcpu="0" cpuset="1-4,^2"/&gt;
    &lt;vcpupin vcpu="1" cpuset="0,1"/&gt;
    &lt;vcpupin vcpu="2" cpuset="2,3"/&gt;
    &lt;vcpupin vcpu="3" cpuset="0,4"/&gt;
J
Jiri Denemark 已提交
661
    &lt;emulatorpin cpuset="1-3"/&gt;
662 663
    &lt;iothreadpin iothread="1" cpuset="5,6"/&gt;
    &lt;iothreadpin iothread="2" cpuset="7,8"/&gt;
664 665 666
    &lt;shares&gt;2048&lt;/shares&gt;
    &lt;period&gt;1000000&lt;/period&gt;
    &lt;quota&gt;-1&lt;/quota&gt;
667 668
    &lt;emulator_period&gt;1000000&lt;/emulator_period&gt;
    &lt;emulator_quota&gt;-1&lt;/emulator_quota&gt;
669 670
    &lt;iothread_period&gt;1000000&lt;/iothread_period&gt;
    &lt;iothread_quota&gt;-1&lt;/iothread_quota&gt;
671 672
    &lt;vcpusched vcpus='0-4,^3' scheduler='fifo' priority='1'/&gt;
    &lt;iothreadsched iothreads='2' scheduler='batch'/&gt;
673 674 675 676 677 678
  &lt;/cputune&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
679
      <dt><code>cputune</code></dt>
680 681 682 683 684
      <dd>
         The optional <code>cputune</code> element provides details
         regarding the cpu tunable parameters for the domain.
         <span class="since">Since 0.9.0</span>
      </dd>
685
      <dt><code>vcpupin</code></dt>
686
      <dd>
687
        The optional <code>vcpupin</code> element specifies which of host's
688 689 690 691 692 693 694
        physical CPUs the domain VCPU will be pinned to. If this is omitted,
        and attribute <code>cpuset</code> of element <code>vcpu</code> is
        not specified, the vCPU is pinned to all the physical CPUs by default.
        It contains two required attributes, the attribute <code>vcpu</code>
        specifies vcpu id, and the attribute <code>cpuset</code> is same as
        attribute <code>cpuset</code> of element <code>vcpu</code>.
        (NB: Only qemu driver support)
695 696
        <span class="since">Since 0.9.0</span>
       </dd>
T
Tang Chen 已提交
697 698 699
       <dt><code>emulatorpin</code></dt>
       <dd>
         The optional <code>emulatorpin</code> element specifies which of host
700 701
         physical CPUs the "emulator", a subset of a domain not including vcpu
         or iothreads will be pinned to. If this is omitted, and attribute
702 703 704
         <code>cpuset</code> of element <code>vcpu</code> is not specified,
         "emulator" is pinned to all the physical CPUs by default. It contains
         one required attribute <code>cpuset</code> specifying which physical
705
         CPUs to pin to.
T
Tang Chen 已提交
706
       </dd>
707 708 709 710 711 712 713
       <dt><code>iothreadpin</code></dt>
       <dd>
         The optional <code>iothreadpin</code> element specifies which of host
         physical CPUs the IOThreads will be pinned to. If this is omitted
         and attribute <code>cpuset</code> of element <code>vcpu</code> is
         not specified, the IOThreads are pinned to all the physical CPUs
         by default. There are two required attributes, the attribute
714 715 716 717 718
         <code>iothread</code> specifies the IOThread ID and the attribute
         <code>cpuset</code> specifying which physical CPUs to pin to. See
         the <code>iothreadids</code>
         <a href="#elementsIOThreadsAllocation"><code>description</code></a>
         for valid <code>iothread</code> values.
719 720
        <span class="since">Since 1.2.9</span>
       </dd>
721
      <dt><code>shares</code></dt>
722 723
      <dd>
        The optional <code>shares</code> element specifies the proportional
724
        weighted share for the domain. If this is omitted, it defaults to
E
Eric Blake 已提交
725 726 727
        the OS provided defaults. NB, There is no unit for the value,
        it's a relative measure based on the setting of other VM,
        e.g. A VM configured with value
728 729 730
        2048 will get twice as much CPU time as a VM configured with value 1024.
        <span class="since">Since 0.9.0</span>
      </dd>
731 732 733 734 735 736
      <dt><code>period</code></dt>
      <dd>
        The optional <code>period</code> element specifies the enforcement
        interval(unit: microseconds). Within <code>period</code>, each vcpu of
        the domain will not be allowed to consume more than <code>quota</code>
        worth of runtime. The value should be in range [1000, 1000000]. A period
737 738 739
        with value 0 means no value.
        <span class="since">Only QEMU driver support since 0.9.4, LXC since
        0.9.10</span>
740 741 742 743 744 745 746 747 748
      </dd>
      <dt><code>quota</code></dt>
      <dd>
        The optional <code>quota</code> element specifies the maximum allowed
        bandwidth(unit: microseconds). A domain with <code>quota</code> as any
        negative value indicates that the domain has infinite bandwidth, which
        means that it is not bandwidth controlled. The value should be in range
        [1000, 18446744073709551] or less than 0. A quota with value 0 means no
        value. You can use this feature to ensure that all vcpus run at the same
749 750 751
        speed.
        <span class="since">Only QEMU driver support since 0.9.4, LXC since
        0.9.10</span>
752
      </dd>
753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774

      <dt><code>emulator_period</code></dt>
      <dd>
        The optional <code>emulator_period</code> element specifies the enforcement
        interval(unit: microseconds). Within <code>emulator_period</code>, emulator
        threads(those excluding vcpus) of the domain will not be allowed to consume
        more than <code>emulator_quota</code> worth of runtime. The value should be
        in range [1000, 1000000]. A period with value 0 means no value.
        <span class="since">Only QEMU driver support since 0.10.0</span>
      </dd>
      <dt><code>emulator_quota</code></dt>
      <dd>
        The optional <code>emulator_quota</code> element specifies the maximum
        allowed bandwidth(unit: microseconds) for domain's emulator threads(those
        excluding vcpus). A domain with <code>emulator_quota</code> as any negative
        value indicates that the domain has infinite bandwidth for emulator threads
        (those excluding vcpus), which means that it is not bandwidth controlled.
        The value should be in range [1000, 18446744073709551] or less than 0. A
        quota with value 0 means no value.
        <span class="since">Only QEMU driver support since 0.10.0</span>
      </dd>

775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797
      <dt><code>iothread_period</code></dt>
      <dd>
        The optional <code>iothread_period</code> element specifies the
        enforcement interval(unit: microseconds) for IOThreads. Within
        <code>iothread_period</code>, each IOThread of the domain will
        not be allowed to consume more than <code>iothread_quota</code>
        worth of runtime. The value should be in range [1000, 1000000].
        An iothread_period with value 0 means no value.
        <span class="since">Only QEMU driver support since 2.1.0</span>
      </dd>
      <dt><code>iothread_quota</code></dt>
      <dd>
        The optional <code>iothread_quota</code> element specifies the maximum
        allowed bandwidth(unit: microseconds) for IOThreads. A domain with
        <code>iothread_quota</code> as any negative value indicates that the
        domain IOThreads have infinite bandwidth, which means that it is
        not bandwidth controlled. The value should be in range
        [1000, 18446744073709551] or less than 0. An <code>iothread_quota</code>
        with value 0 means no value. You can use this feature to ensure that
        all IOThreads run at the same speed.
        <span class="since">Only QEMU driver support since 2.1.0</span>
      </dd>

798 799 800 801 802 803
      <dt><code>vcpusched</code> and <code>iothreadsched</code></dt>
      <dd>
        The optional <code>vcpusched</code> elements specifies the scheduler
        type (values <code>batch</code>, <code>idle</code>, <code>fifo</code>,
        <code>rr</code>) for particular vCPU/IOThread threads (based on
        <code>vcpus</code> and <code>iothreads</code>, leaving out
804 805 806 807 808 809 810 811
        <code>vcpus</code>/<code>iothreads</code> sets the default). Valid
        <code>vcpus</code> values start at 0 through one less than the
        number of vCPU's defined for the domain. Valid <code>iothreads</code>
        values are described in the <code>iothreadids</code>
        <a href="#elementsIOThreadsAllocation"><code>description</code></a>.
        If no <code>iothreadids</code> are defined, then libvirt numbers
        IOThreads from 1 to the number of <code>iothreads</code> available
        for the domain. For real-time schedulers (<code>fifo</code>,
812
        <code>rr</code>), priority must be specified as
813 814
        well (and is ignored for non-real-time ones). The value range
        for the priority depends on the host kernel (usually 1-99).
815
        <span class="since">Since 1.2.13</span>
816 817
      </dd>

818 819 820 821 822 823 824 825
    </dl>


    <h3><a name="elementsMemoryAllocation">Memory Allocation</a></h3>

<pre>
&lt;domain&gt;
  ...
826
  &lt;maxMemory slots='16' unit='KiB'&gt;1524288&lt;/maxMemory&gt;
E
Eric Blake 已提交
827 828
  &lt;memory unit='KiB'&gt;524288&lt;/memory&gt;
  &lt;currentMemory unit='KiB'&gt;524288&lt;/currentMemory&gt;
829 830 831 832 833 834
  ...
&lt;/domain&gt;
</pre>

    <dl>
      <dt><code>memory</code></dt>
835 836 837
      <dd>The maximum allocation of memory for the guest at boot time. The
        memory allocation includes possible additional memory devices specified
        at start or hotplugged later.
E
Eric Blake 已提交
838
        The units for this value are determined by the optional
839
        attribute <code>unit</code>, which defaults to "KiB"
E
Eric Blake 已提交
840 841 842 843 844 845 846 847 848 849 850 851 852
        (kibibytes, 2<sup>10</sup> or blocks of 1024 bytes).  Valid
        units are "b" or "bytes" for bytes, "KB" for kilobytes
        (10<sup>3</sup> or 1,000 bytes), "k" or "KiB" for kibibytes
        (1024 bytes), "MB" for megabytes (10<sup>6</sup> or 1,000,000
        bytes), "M" or "MiB" for mebibytes (2<sup>20</sup> or
        1,048,576 bytes), "GB" for gigabytes (10<sup>9</sup> or
        1,000,000,000 bytes), "G" or "GiB" for gibibytes
        (2<sup>30</sup> or 1,073,741,824 bytes), "TB" for terabytes
        (10<sup>12</sup> or 1,000,000,000,000 bytes), or "T" or "TiB"
        for tebibytes (2<sup>40</sup> or 1,099,511,627,776 bytes).
        However, the value will be rounded up to the nearest kibibyte
        by libvirt, and may be further rounded to the granularity
        supported by the hypervisor.  Some hypervisors also enforce a
853 854
        minimum, such as 4000KiB.

855 856 857
        In case <a href="#elementsCPU">NUMA</a> is configured for the guest the
        <code>memory</code> element can be omitted.

858 859 860 861 862 863 864
        In the case of crash, optional attribute <code>dumpCore</code>
        can be used to control whether the guest memory should be
        included in the generated coredump or not (values "on", "off").

        <span class='since'><code>unit</code> since 0.9.11</span>,
        <span class='since'><code>dumpCore</code> since 0.10.2
        (QEMU only)</span></dd>
865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880
      <dt><code>maxMemory</code></dt>
      <dd>The run time maximum memory allocation of the guest. The initial
        memory specified by either the <code>&lt;memory&gt;</code> element or
        the NUMA cell size configuration can be increased by hot-plugging of
        memory to the limit specified by this element.

        The <code>unit</code> attribute behaves the same as for
        <code>&lt;memory&gt;</code>.

        The <code>slots</code> attribute specifies the number of slots
        available for adding memory to the guest. The bounds are hypervisor
        specific.

        Note that due to alignment of the memory chunks added via memory
        hotplug the full size allocation specified by this element may be
        impossible to achieve.
881
        <span class='since'>Since 1.2.14 supported by the QEMU driver.</span>
882 883
      </dd>

884 885 886 887
      <dt><code>currentMemory</code></dt>
      <dd>The actual allocation of memory for the guest. This value can
        be less than the maximum allocation, to allow for ballooning
        up the guests memory on the fly. If this is omitted, it defaults
E
Eric Blake 已提交
888 889 890
        to the same value as the <code>memory</code> element.
        The <code>unit</code> attribute behaves the same as
        for <code>memory</code>.</dd>
891 892 893 894 895 896 897 898 899
    </dl>


    <h3><a name="elementsMemoryBacking">Memory Backing</a></h3>

<pre>
&lt;domain&gt;
  ...
  &lt;memoryBacking&gt;
900 901 902
    &lt;hugepages&gt;
      &lt;page size="1" unit="G" nodeset="0-3,5"/&gt;
      &lt;page size="2" unit="M" nodeset="4"/&gt;
903
    &lt;/hugepages&gt;
904
    &lt;nosharepages/&gt;
905
    &lt;locked/&gt;
906 907 908
    &lt;source type="file|anonymous"/&gt;
    &lt;access mode="shared|private"/&gt;
    &lt;allocation mode="immediate|ondemand"/&gt;
909 910 911 912 913
  &lt;/memoryBacking&gt;
  ...
&lt;/domain&gt;
</pre>

914 915 916 917
    <p>The optional <code>memoryBacking</code> element may contain several
      elements that influence how virtual memory pages are backed by host
      pages.</p>

918
    <dl>
919 920
      <dt><code>hugepages</code></dt>
      <dd>This tells the hypervisor that the guest should have its memory
921 922 923 924 925 926 927 928 929 930 931 932 933
      allocated using hugepages instead of the normal native page size.
      <span class='since'>Since 1.2.5</span> it's possible to set hugepages
      more specifically per numa node. The <code>page</code> element is
      introduced. It has one compulsory attribute <code>size</code> which
      specifies which hugepages should be used (especially useful on systems
      supporting hugepages of different sizes). The default unit for the
      <code>size</code> attribute is kilobytes (multiplier of 1024). If you
      want to use different unit, use optional <code>unit</code> attribute.
      For systems with NUMA, the optional <code>nodeset</code> attribute may
      come handy as it ties given guest's NUMA nodes to certain hugepage
      sizes. From the example snippet, one gigabyte hugepages are used for
      every NUMA node except node number four. For the correct syntax see
      <a href="#elementsNUMATuning">this</a>.</dd>
934 935 936 937 938 939
      <dt><code>nosharepages</code></dt>
      <dd>Instructs hypervisor to disable shared pages (memory merge, KSM) for
        this domain. <span class="since">Since 1.0.6</span></dd>
      <dt><code>locked</code></dt>
      <dd>When set and supported by the hypervisor, memory pages belonging
        to the domain will be locked in host's memory and the host will not
940
        be allowed to swap them out. For QEMU/KVM this requires
E
Eric Blake 已提交
941
        <code>hard_limit</code> <a href="#elementsMemoryTuning">memory tuning</a>
942
        element to be used and set to the maximum memory configured for the
943 944 945 946 947
        domain plus any memory consumed by the QEMU process itself. Beware of
        setting the memory limit too high (and thus allowing the domain to lock
        most of the host's memory). Doing so may be dangerous to both the
        domain and the host itself since the host's kernel may run out of
        memory. <span class="since">Since 1.0.6</span></dd>
948 949 950 951 952 953
       <dt><code>source</code></dt>
       <dd>In this attribute you can switch to file memorybacking or keep default anonymous.</dd>
       <dt><code>access</code></dt>
       <dd>Specify if memory is shared or private. This can be overridden per numa node by <code>memAccess</code></dd>
       <dt><code>allocation</code></dt>
       <dd>Specify when allocate the memory</dd>
954 955 956 957 958 959 960 961 962
    </dl>


    <h3><a name="elementsMemoryTuning">Memory Tuning</a></h3>

<pre>
&lt;domain&gt;
  ...
  &lt;memtune&gt;
E
Eric Blake 已提交
963 964 965 966
    &lt;hard_limit unit='G'&gt;1&lt;/hard_limit&gt;
    &lt;soft_limit unit='M'&gt;128&lt;/soft_limit&gt;
    &lt;swap_hard_limit unit='G'&gt;2&lt;/swap_hard_limit&gt;
    &lt;min_guarantee unit='bytes'&gt;67108864&lt;/min_guarantee&gt;
967 968 969 970 971 972 973 974 975 976 977 978 979
  &lt;/memtune&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
      <dt><code>memtune</code></dt>
      <dd> The optional <code>memtune</code> element provides details
        regarding the memory tunable parameters for the domain. If this is
        omitted, it defaults to the OS provided defaults. For QEMU/KVM, the
        parameters are applied to the QEMU process as a whole. Thus, when
        counting them, one needs to add up guest RAM, guest video RAM, and
        some memory overhead of QEMU itself. The last piece is hard to
E
Eric Blake 已提交
980 981 982 983 984 985
        determine so one needs guess and try.  For each tunable, it
        is possible to designate which unit the number is in on
        input, using the same values as
        for <code>&lt;memory&gt;</code>.  For backwards
        compatibility, output is always in
        KiB.  <span class='since'><code>unit</code>
986 987 988
        since 0.9.11</span>
        Possible values for all *_limit parameters are in range from 0 to
        VIR_DOMAIN_MEMORY_PARAM_UNLIMITED.</dd>
989 990
      <dt><code>hard_limit</code></dt>
      <dd> The optional <code>hard_limit</code> element is the maximum memory
991
        the guest can use. The units for this value are kibibytes (i.e. blocks
992
        of 1024 bytes). <strong>However, users of QEMU and KVM are strongly
M
Michal Privoznik 已提交
993 994 995
        advised not to set this limit as domain may get killed by the kernel
        if the guess is too low. To determine the memory needed for a process
        to run is an
996 997
        <a href="http://en.wikipedia.org/wiki/Undecidable_problem">
        undecidable problem</a>.</strong></dd>
998 999 1000
      <dt><code>soft_limit</code></dt>
      <dd> The optional <code>soft_limit</code> element is the memory limit to
        enforce during memory contention. The units for this value are
1001
        kibibytes (i.e. blocks of 1024 bytes)</dd>
1002 1003 1004
      <dt><code>swap_hard_limit</code></dt>
      <dd> The optional <code>swap_hard_limit</code> element is the maximum
        memory plus swap the guest can use. The units for this value are
1005
        kibibytes (i.e. blocks of 1024 bytes). This has to be more than
1006 1007 1008 1009
        hard_limit value provided</dd>
      <dt><code>min_guarantee</code></dt>
      <dd> The optional <code>min_guarantee</code> element is the guaranteed
        minimum memory allocation for the guest. The units for this value are
1010 1011
        kibibytes (i.e. blocks of 1024 bytes). This element is only supported
        by VMware ESX and OpenVZ drivers.</dd>
1012 1013 1014 1015 1016 1017 1018 1019 1020 1021
    </dl>


    <h3><a name="elementsNUMATuning">NUMA Node Tuning</a></h3>

<pre>
&lt;domain&gt;
  ...
  &lt;numatune&gt;
    &lt;memory mode="strict" nodeset="1-4,^3"/&gt;
1022 1023
    &lt;memnode cellid="0" mode="strict" nodeset="1"/&gt;
    &lt;memnode cellid="2" mode="preferred" nodeset="2"/&gt;
1024 1025 1026 1027 1028 1029
  &lt;/numatune&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
1030 1031 1032 1033 1034 1035
      <dt><code>numatune</code></dt>
      <dd>
        The optional <code>numatune</code> element provides details of
        how to tune the performance of a NUMA host via controlling NUMA policy
        for domain process. NB, only supported by QEMU driver.
        <span class='since'>Since 0.9.3</span>
1036
      </dd>
1037 1038
      <dt><code>memory</code></dt>
      <dd>
O
Osier Yang 已提交
1039
        The optional <code>memory</code> element specifies how to allocate memory
1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057
        for the domain process on a NUMA host. It contains several optional
        attributes. Attribute <code>mode</code> is either 'interleave',
        'strict', or 'preferred', defaults to 'strict'. Attribute
        <code>nodeset</code> specifies the NUMA nodes, using the same syntax as
        attribute <code>cpuset</code> of element <code>vcpu</code>. Attribute
        <code>placement</code> (<span class='since'>since 0.9.12</span>) can be
        used to indicate the memory placement mode for domain process, its value
        can be either "static" or "auto", defaults to <code>placement</code> of
        <code>vcpu</code>, or "static" if <code>nodeset</code> is specified.
        "auto" indicates the domain process will only allocate memory from the
        advisory nodeset returned from querying numad, and the value of attribute
        <code>nodeset</code> will be ignored if it's specified.

        If <code>placement</code> of <code>vcpu</code> is 'auto', and
        <code>numatune</code> is not specified, a default <code>numatune</code>
        with <code>placement</code> 'auto' and <code>mode</code> 'strict' will
        be added implicitly.

1058 1059
        <span class='since'>Since 0.9.3</span>
      </dd>
1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072
      <dt><code>memnode</code></dt>
      <dd>
        Optional <code>memnode</code> elements can specify memory allocation
        policies per each guest NUMA node.  For those nodes having no
        corresponding <code>memnode</code> element, the default from
        element <code>memory</code> will be used.  Attribute <code>cellid</code>
        addresses guest NUMA node for which the settings are applied.
        Attributes <code>mode</code> and <code>nodeset</code> have the same
        meaning and syntax as in <code>memory</code> element.

        This setting is not compatible with automatic placement.
        <span class='since'>QEMU Since 1.2.7</span>
      </dd>
D
Daniel P. Berrange 已提交
1073 1074
    </dl>

1075 1076 1077 1078 1079 1080 1081

    <h3><a name="elementsBlockTuning">Block I/O Tuning</a></h3>
<pre>
&lt;domain&gt;
  ...
  &lt;blkiotune&gt;
    &lt;weight&gt;800&lt;/weight&gt;
1082 1083 1084 1085 1086 1087 1088
    &lt;device&gt;
      &lt;path&gt;/dev/sda&lt;/path&gt;
      &lt;weight&gt;1000&lt;/weight&gt;
    &lt;/device&gt;
    &lt;device&gt;
      &lt;path&gt;/dev/sdb&lt;/path&gt;
      &lt;weight&gt;500&lt;/weight&gt;
1089 1090 1091 1092
      &lt;read_bytes_sec&gt;10000&lt;/read_bytes_sec&gt;
      &lt;write_bytes_sec&gt;10000&lt;/write_bytes_sec&gt;
      &lt;read_iops_sec&gt;20000&lt;/read_iops_sec&gt;
      &lt;write_iops_sec&gt;20000&lt;/write_iops_sec&gt;
1093
    &lt;/device&gt;
1094 1095 1096 1097 1098 1099 1100 1101 1102
  &lt;/blkiotune&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
      <dt><code>blkiotune</code></dt>
      <dd> The optional <code>blkiotune</code> element provides the ability
        to tune Blkio cgroup tunable parameters for the domain. If this is
1103 1104
        omitted, it defaults to the OS provided
        defaults. <span class="since">Since 0.8.8</span></dd>
1105
      <dt><code>weight</code></dt>
1106 1107
      <dd> The optional <code>weight</code> element is the overall I/O
        weight of the guest. The value should be in the range [100,
1108 1109
        1000]. After kernel 2.6.39, the value could be in the
        range [10, 1000].</dd>
1110 1111 1112 1113 1114 1115 1116 1117
      <dt><code>device</code></dt>
      <dd>The domain may have multiple <code>device</code> elements
        that further tune the weights for each host block device in
        use by the domain.  Note that
        multiple <a href="#elementsDisks">guest disks</a> can share a
        single host block device, if they are backed by files within
        the same host file system, which is why this tuning parameter
        is at the global domain level rather than associated with each
L
Lei Li 已提交
1118 1119 1120 1121 1122
        guest disk device (contrast this to
        the <a href="#elementsDisks"><code>&lt;iotune&gt;</code></a>
        element which can apply to an
        individual <code>&lt;disk&gt;</code>).
        Each <code>device</code> element has two
1123 1124 1125
        mandatory sub-elements, <code>path</code> describing the
        absolute path of the device, and <code>weight</code> giving
        the relative weight of that device, in the range [100,
1126
        1000]. After kernel 2.6.39, the value could be in the
1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142
        range [10, 1000]. <span class="since">Since 0.9.8</span><br/>
        Additionally, the following optional sub-elements can be used:
        <dl>
          <dt><code>read_bytes_sec</code></dt>
          <dd>Read throughput limit in bytes per second.
            <span class="since">Since 1.2.2</span></dd>
          <dt><code>write_bytes_sec</code></dt>
          <dd>Write throughput limit in bytes per second.
            <span class="since">Since 1.2.2</span></dd>
          <dt><code>read_iops_sec</code></dt>
          <dd>Read I/O operations per second limit.
            <span class="since">Since 1.2.2</span></dd>
          <dt><code>write_iops_sec</code></dt>
          <dd>Write I/O operations per second limit.
            <span class="since">Since 1.2.2</span></dd>
      </dl></dd></dl>
1143 1144


1145 1146 1147 1148 1149 1150 1151
    <h3><a name="resPartition">Resource partitioning</a></h3>

    <p>
      Hypervisors may allow for virtual machines to be placed into
      resource partitions, potentially with nesting of said partitions.
      The <code>resource</code> element groups together configuration
      related to resource partitioning. It currently supports a child
1152
      element <code>partition</code> whose content defines the absolute path
1153 1154 1155 1156 1157 1158 1159 1160
      of the resource partition in which to place the domain. If no
      partition is listed, then the domain will be placed in a default
      partition. It is the responsibility of the app/admin to ensure
      that the partition exists prior to starting the guest. Only the
      (hypervisor specific) default partition can be assumed to exist
      by default.
    </p>
<pre>
1161 1162 1163 1164 1165
...
&lt;resource&gt;
  &lt;partition&gt;/virtualmachines/production&lt;/partition&gt;
&lt;/resource&gt;
...
1166 1167 1168 1169
</pre>

    <p>
      Resource partitions are currently supported by the QEMU and
E
Eric Blake 已提交
1170
      LXC drivers, which map partition paths to cgroups directories,
1171 1172 1173
      in all mounted controllers. <span class="since">Since 1.0.5</span>
    </p>

1174 1175 1176 1177 1178 1179 1180 1181
    <h3><a name="elementsCPU">CPU model and topology</a></h3>

    <p>
      Requirements for CPU model, its features and topology can be specified
      using the following collection of elements.
      <span class="since">Since 0.7.5</span>
    </p>

1182
<pre>
1183 1184 1185 1186 1187 1188 1189 1190
...
&lt;cpu match='exact'&gt;
  &lt;model fallback='allow'&gt;core2duo&lt;/model&gt;
  &lt;vendor&gt;Intel&lt;/vendor&gt;
  &lt;topology sockets='1' cores='2' threads='1'/&gt;
  &lt;feature policy='disable' name='lahf_lm'/&gt;
&lt;/cpu&gt;
...</pre>
1191

1192
<pre>
1193 1194 1195 1196 1197
&lt;cpu mode='host-model'&gt;
  &lt;model fallback='forbid'/&gt;
  &lt;topology sockets='1' cores='2' threads='1'/&gt;
&lt;/cpu&gt;
...</pre>
1198 1199

<pre>
1200 1201 1202
&lt;cpu mode='host-passthrough'&gt;
  &lt;feature policy='disable' name='lahf_lm'/&gt;
...</pre>
1203

1204 1205 1206 1207 1208 1209
    <p>
      In case no restrictions need to be put on CPU model and its features, a
      simpler <code>cpu</code> element can be used.
      <span class="since">Since 0.7.6</span>
    </p>

1210
<pre>
1211 1212 1213 1214 1215
...
&lt;cpu&gt;
  &lt;topology sockets='1' cores='2' threads='1'/&gt;
&lt;/cpu&gt;
...</pre>
1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237

    <dl>
      <dt><code>cpu</code></dt>
      <dd>The <code>cpu</code> element is the main container for describing
        guest CPU requirements. Its <code>match</code> attribute specified how
        strictly has the virtual CPU provided to the guest match these
        requirements. <span class="since">Since 0.7.6</span> the
        <code>match</code> attribute can be omitted if <code>topology</code>
        is the only element within <code>cpu</code>. Possible values for the
        <code>match</code> attribute are:

        <dl>
          <dt><code>minimum</code></dt>
          <dd>The specified CPU model and features describes the minimum
            requested CPU.</dd>
          <dt><code>exact</code></dt>
          <dd>The virtual CPU provided to the guest will exactly match the
            specification</dd>
          <dt><code>strict</code></dt>
          <dd>The guest will not be created unless the host CPU does exactly
            match the specification.</dd>
        </dl>
1238

E
Eric Blake 已提交
1239 1240
        <span class="since">Since 0.8.5</span> the <code>match</code>
        attribute can be omitted and will default to <code>exact</code>.
1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258

        <span class="since">Since 0.9.10</span>, an optional <code>mode</code>
        attribute may be used to make it easier to configure a guest CPU to be
        as close to host CPU as possible. Possible values for the
        <code>mode</code> attribute are:

        <dl>
          <dt><code>custom</code></dt>
          <dd>In this mode, the <code>cpu</code> element describes the CPU
          that should be presented to the guest. This is the default when no
          <code>mode</code> attribute is specified. This mode makes it so that
          a persistent guest will see the same hardware no matter what host
          the guest is booted on.</dd>
          <dt><code>host-model</code></dt>
          <dd>The <code>host-model</code> mode is essentially a shortcut to
          copying host CPU definition from capabilities XML into domain XML.
          Since the CPU definition is copied just before starting a domain,
          exactly the same XML can be used on different hosts while still
1259 1260 1261 1262 1263 1264 1265 1266 1267
          providing the best guest CPU each host supports. The
          <code>match</code> attribute can't be used in this mode. Specifying
          CPU model is not supported either, but <code>model</code>'s
          <code>fallback</code> attribute may still be used. Using the
          <code>feature</code> element, specific flags may be enabled or
          disabled specifically in addition to the host model. This may be
          used to fine tune features that can be emulated.
          <span class="since">(Since 1.1.1)</span>.
          Libvirt does not model every aspect of each CPU so
1268 1269 1270 1271 1272 1273 1274
          the guest CPU will not match the host CPU exactly. On the other
          hand, the ABI provided to the guest is reproducible. During
          migration, complete CPU model definition is transferred to the
          destination host so the migrated guest will see exactly the same CPU
          model even if the destination host contains more capable CPUs for
          the running instance of the guest; but shutting down and restarting
          the guest may present different hardware to the guest according to
1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289
          the capabilities of the new host. Prior to libvirt 3.2.0 and QEMU
          2.9.0 detection of the host CPU model via QEMU is not supported.
          Thus the CPU configuration created using <code>host-model</code>
          may not work as expected.
          <span class="since">Since 3.2.0 and QEMU 2.9.0</span> this mode
          works the way it was designed and it is indicated by the
          <code>fallback</code> attribute set to <code>forbid</code> in the
          host-model CPU definition advertised in
          <a href="formatdomaincaps.html#elementsCPU">domain capabilities XML</a>.
          When <code>fallback</code> attribute is set to <code>allow</code>
          in the domain capabilities XML, it is recommended to use
          <code>custom</code> mode with just the CPU model from the host
          capabilities XML. <span class="since">Since 1.2.11</span> PowerISA
          allows processors to run VMs in binary compatibility mode supporting
          an older version of ISA.  Libvirt on PowerPC architecture uses the
1290 1291 1292 1293 1294
          <code>host-model</code> to signify a guest mode CPU running in
          binary compatibility mode. Example:
          When a user needs a power7 VM to run in compatibility mode
          on a Power8 host, this can be described in XML as follows :
<pre>
1295 1296 1297 1298
&lt;cpu mode='host-model'&gt;
  &lt;model&gt;power7&lt;/model&gt;
&lt;/cpu&gt;
...</pre>
1299
          </dd>
1300 1301 1302 1303 1304
          <dt><code>host-passthrough</code></dt>
          <dd>With this mode, the CPU visible to the guest should be exactly
          the same as the host CPU even in the aspects that libvirt does not
          understand. Though the downside of this mode is that the guest
          environment cannot be reproduced on different hardware. Thus, if you
1305
          hit any bugs, you are on your own. Further details of that CPU can
1306 1307 1308 1309 1310
          be changed using <code>feature</code> elements. Migration of a guest
          using host-passthrough is dangerous if the source and destination
          hosts are not identical in both hardware and configuration. If such
          a migration is attempted then the guest may hang or crash upon
          resuming execution on the destination host.</dd>
1311
        </dl>
1312 1313 1314 1315 1316 1317 1318 1319 1320

        Both <code>host-model</code> and <code>host-passthrough</code> modes
        make sense when a domain can run directly on the host CPUs (for
        example, domains with type <code>kvm</code>). The actual host CPU is
        irrelevant for domains with emulated virtual CPUs (such as domains with
        type <code>qemu</code>). However, for backward compatibility
        <code>host-model</code> may be implemented even for domains running on
        emulated CPUs in which case the best CPU the hypervisor is able to
        emulate may be used rather then trying to mimic the host CPU model.
1321 1322 1323 1324 1325 1326
      </dd>

      <dt><code>model</code></dt>
      <dd>The content of the <code>model</code> element specifies CPU model
        requested by the guest. The list of available CPU models and their
        definition can be found in <code>cpu_map.xml</code> file installed
1327 1328 1329 1330 1331 1332 1333 1334
        in libvirt's data directory. If a hypervisor is not able to use the
        exact CPU model, libvirt automatically falls back to a closest model
        supported by the hypervisor while maintaining the list of CPU
        features. <span class="since">Since 0.9.10</span>, an optional
        <code>fallback</code> attribute can be used to forbid this behavior,
        in which case an attempt to start a domain requesting an unsupported
        CPU model will fail. Supported values for <code>fallback</code>
        attribute are: <code>allow</code> (this is the default), and
1335
        <code>forbid</code>. The optional <code>vendor_id</code> attribute
1336
        (<span class="since">Since 0.10.0</span>)  can be used to set the
1337 1338 1339
        vendor id seen by the guest. It must be exactly 12 characters long.
        If not set the vendor id of the host is used. Typical possible
        values are "AuthenticAMD" and "GenuineIntel".</dd>
1340

J
Jiri Denemark 已提交
1341 1342 1343 1344 1345 1346 1347
      <dt><code>vendor</code></dt>
      <dd><span class="since">Since 0.8.3</span> the content of the
        <code>vendor</code> element specifies CPU vendor requested by the
        guest. If this element is missing, the guest can be run on a CPU
        matching given features regardless on its vendor. The list of
        supported vendors can be found in <code>cpu_map.xml</code>.</dd>

1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378
      <dt><code>topology</code></dt>
      <dd>The <code>topology</code> element specifies requested topology of
        virtual CPU provided to the guest. Three non-zero values have to be
        given for <code>sockets</code>, <code>cores</code>, and
        <code>threads</code>: total number of CPU sockets, number of cores per
        socket, and number of threads per core, respectively.</dd>

      <dt><code>feature</code></dt>
      <dd>The <code>cpu</code> element can contain zero or more
        <code>elements</code> used to fine-tune features provided by the
        selected CPU model. The list of known feature names can be found in
        the same file as CPU models. The meaning of each <code>feature</code>
        element depends on its <code>policy</code> attribute, which has to be
        set to one of the following values:

        <dl>
          <dt><code>force</code></dt>
          <dd>The virtual CPU will claim the feature is supported regardless
            of it being supported by host CPU.</dd>
          <dt><code>require</code></dt>
          <dd>Guest creation will fail unless the feature is supported by host
            CPU.</dd>
          <dt><code>optional</code></dt>
          <dd>The feature will be supported by virtual CPU if and only if it
            is supported by host CPU.</dd>
          <dt><code>disable</code></dt>
          <dd>The feature will not be supported by virtual CPU.</dd>
          <dt><code>forbid</code></dt>
          <dd>Guest creation will fail if the feature is supported by host
            CPU.</dd>
        </dl>
1379

E
Eric Blake 已提交
1380 1381
        <span class="since">Since 0.8.5</span> the <code>policy</code>
        attribute can be omitted and will default to <code>require</code>.
1382 1383 1384
      </dd>
    </dl>

1385
    <p>
1386
      Guest NUMA topology can be specified using the <code>numa</code> element.
1387 1388 1389 1390
      <span class="since">Since 0.9.8</span>
    </p>

<pre>
1391 1392
...
&lt;cpu&gt;
1393
  ...
1394 1395 1396 1397 1398 1399 1400
  &lt;numa&gt;
    &lt;cell id='0' cpus='0-3' memory='512000' unit='KiB'/&gt;
    &lt;cell id='1' cpus='4-7' memory='512000' unit='KiB' memAccess='shared'/&gt;
  &lt;/numa&gt;
  ...
&lt;/cpu&gt;
...</pre>
1401 1402 1403

    <p>
      Each <code>cell</code> element specifies a NUMA cell or a NUMA node.
1404 1405 1406
      <code>cpus</code> specifies the CPU or range of CPUs that are
      part of the node. <code>memory</code> specifies the node memory
      in kibibytes (i.e. blocks of 1024 bytes).
1407 1408 1409
      <span class="since">Since 1.2.11</span> one can use an additional <a
          href="#elementsMemoryAllocation"><code>unit</code></a> attribute to
      define units in which <code>memory</code> is specified.
1410 1411 1412 1413 1414 1415
      <span class="since">Since 1.2.7</span> all cells should
      have <code>id</code> attribute in case referring to some cell is
      necessary in the code, otherwise the cells are
      assigned <code>id</code>s in the increasing order starting from
      0.  Mixing cells with and without the <code>id</code> attribute
      is not recommended as it may result in unwanted behaviour.
1416 1417 1418 1419

      <span class='since'>Since 1.2.9</span> the optional attribute
      <code>memAccess</code> can control whether the memory is to be
      mapped as "shared" or "private".  This is valid only for
1420
      hugepages-backed memory and nvdimm modules.
1421 1422 1423 1424 1425 1426
    </p>

    <p>
      This guest NUMA specification is currently available only for QEMU/KVM.
    </p>

1427
    <h3><a name="elementsEvents">Events configuration</a></h3>
D
Daniel P. Berrange 已提交
1428 1429

    <p>
A
Atsushi SAKAI 已提交
1430
      It is sometimes necessary to override the default actions taken
1431 1432
      on various events. Not all hypervisors support all events and actions.
      The actions may be taken as a result of calls to libvirt APIs
1433 1434 1435 1436 1437 1438 1439 1440 1441 1442
      <a href="html/libvirt-libvirt-domain.html#virDomainReboot">
        <code>virDomainReboot</code>
      </a>,
      <a href="html/libvirt-libvirt-domain.html#virDomainShutdown">
        <code>virDomainShutdown</code>
      </a>,
      or
      <a href="html/libvirt-libvirt-domain.html#virDomainShutdownFlags">
        <code>virDomainShutdownFlags</code>
      </a>.
1443 1444
      Using <code>virsh reboot</code> or <code>virsh shutdown</code> would
      also trigger the event.
D
Daniel P. Berrange 已提交
1445 1446
    </p>

1447
<pre>
1448 1449 1450 1451 1452 1453
...
&lt;on_poweroff&gt;destroy&lt;/on_poweroff&gt;
&lt;on_reboot&gt;restart&lt;/on_reboot&gt;
&lt;on_crash&gt;restart&lt;/on_crash&gt;
&lt;on_lockfailure&gt;poweroff&lt;/on_lockfailure&gt;
...</pre>
D
Daniel P. Berrange 已提交
1454

1455 1456 1457 1458 1459 1460 1461
    <p>
      The following collections of elements allow the actions to be
      specified when a guest OS triggers a lifecycle operation. A
      common use case is to force a reboot to be treated as a poweroff
      when doing the initial OS installation. This allows the VM to be
      re-configured for the first post-install bootup.
    </p>
D
Daniel P. Berrange 已提交
1462 1463 1464
    <dl>
      <dt><code>on_poweroff</code></dt>
      <dd>The content of this element specifies the action to take when
M
Matthew Booth 已提交
1465
        the guest requests a poweroff.</dd>
D
Daniel Veillard 已提交
1466
      <dt><code>on_reboot</code></dt>
D
Daniel P. Berrange 已提交
1467
      <dd>The content of this element specifies the action to take when
M
Matthew Booth 已提交
1468
        the guest requests a reboot.</dd>
D
Daniel Veillard 已提交
1469
      <dt><code>on_crash</code></dt>
D
Daniel P. Berrange 已提交
1470
      <dd>The content of this element specifies the action to take when
M
Matthew Booth 已提交
1471
        the guest crashes.</dd>
D
Daniel P. Berrange 已提交
1472 1473 1474 1475 1476 1477 1478 1479 1480
    </dl>

    <p>
      Each of these states allow for the same four possible actions.
    </p>

    <dl>
      <dt><code>destroy</code></dt>
      <dd>The domain will be terminated completely and all resources
1481
        released.</dd>
D
Daniel P. Berrange 已提交
1482
      <dt><code>restart</code></dt>
1483 1484
      <dd>The domain will be terminated and then restarted with
        the same configuration.</dd>
D
Daniel P. Berrange 已提交
1485
      <dt><code>preserve</code></dt>
1486
      <dd>The domain will be terminated and its resource preserved
M
Matthew Booth 已提交
1487
        to allow analysis.</dd>
D
Daniel P. Berrange 已提交
1488
      <dt><code>rename-restart</code></dt>
1489 1490
      <dd>The domain will be terminated and then restarted with
        a new name.</dd>
D
Daniel P. Berrange 已提交
1491 1492
    </dl>

1493
    <p>
1494 1495 1496 1497 1498 1499 1500 1501 1502 1503
    QEMU/KVM supports the <code>on_poweroff</code> and <code>on_reboot</code>
    events handling the <code>destroy</code> and <code>restart</code> actions.
    The <code>preserve</code> action for an <code>on_reboot</code> event
    is treated as a <code>destroy</code> and the <code>rename-restart</code>
    action for an <code>on_poweroff</code> event is treated as a
    <code>restart</code> event.
    </p>

    <p>
      The <code>on_crash</code> event supports these additional
1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516
      actions <span class="since">since 0.8.4</span>.
    </p>

    <dl>
      <dt><code>coredump-destroy</code></dt>
      <dd>The crashed domain's core will be dumped, and then the
        domain will be terminated completely and all resources
        released</dd>
      <dt><code>coredump-restart</code></dt>
      <dd>The crashed domain's core will be dumped, and then the
        domain will be restarted with the same configuration</dd>
    </dl>

1517 1518
    <p>
      The <code>on_lockfailure</code> element (<span class="since">since
1519
      1.0.0</span>) may be used to configure what action should be
1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537
      taken when a lock manager loses resource locks. The following
      actions are recognized by libvirt, although not all of them need
      to be supported by individual lock managers. When no action is
      specified, each lock manager will take its default action.
    </p>
    <dl>
      <dt><code>poweroff</code></dt>
      <dd>The domain will be forcefully powered off.</dd>
      <dt><code>restart</code></dt>
      <dd>The domain will be powered off and started up again to
        reacquire its locks.</dd>
      <dt><code>pause</code></dt>
      <dd>The domain will be paused so that it can be manually resumed
        when lock issues are solved.</dd>
      <dt><code>ignore</code></dt>
      <dd>Keep the domain running as if nothing happened.</dd>
    </dl>

1538 1539 1540 1541 1542 1543 1544 1545 1546
    <h3><a name="elementsPowerManagement">Power Management</a></h3>

    <p>
      <span class="since">Since 0.10.2</span> it is possible to
      forcibly enable or disable BIOS advertisements to the guest
      OS. (NB: Only qemu driver support)
    </p>

<pre>
1547 1548 1549 1550 1551 1552
...
&lt;pm&gt;
  &lt;suspend-to-disk enabled='no'/&gt;
  &lt;suspend-to-mem enabled='yes'/&gt;
&lt;/pm&gt;
...</pre>
1553 1554 1555 1556

    <dl>
      <dt><code>pm</code></dt>
      <dd>These elements enable ('yes') or disable ('no') BIOS support
1557
        for S3 (suspend-to-mem) and S4 (suspend-to-disk) ACPI sleep
1558 1559 1560 1561
        states. If nothing is specified, then the hypervisor will be
        left with its default value.</dd>
    </dl>

D
Daniel P. Berrange 已提交
1562 1563 1564 1565 1566 1567 1568
    <h3><a name="elementsFeatures">Hypervisor features</a></h3>

    <p>
      Hypervisors may allow certain CPU / machine features to be
      toggled on/off.
    </p>

1569
<pre>
1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594
...
&lt;features&gt;
  &lt;pae/&gt;
  &lt;acpi/&gt;
  &lt;apic/&gt;
  &lt;hap/&gt;
  &lt;privnet/&gt;
  &lt;hyperv&gt;
    &lt;relaxed state='on'/&gt;
    &lt;vapic state='on'/&gt;
    &lt;spinlocks state='on' retries='4096'/&gt;
    &lt;vpindex state='on'/&gt;
    &lt;runtime state='on'/&gt;
    &lt;synic state='on'/&gt;
    &lt;reset state='on'/&gt;
    &lt;vendor_id state='on' value='KVM Hv'/&gt;
  &lt;/hyperv&gt;
  &lt;kvm&gt;
    &lt;hidden state='on'/&gt;
  &lt;/kvm&gt;
  &lt;pvspinlock state='on'/&gt;
  &lt;gic version='2'/&gt;

&lt;/features&gt;
...</pre>
D
Daniel P. Berrange 已提交
1595 1596 1597 1598 1599

    <p>
      All features are listed within the <code>features</code>
      element, omitting a togglable feature tag turns it off.
      The available features can be found by asking
1600 1601
      for the <a href="formatcaps.html">capabilities XML</a> and
      <a href="formatdomaincaps.html">domain capabilities XML</a>,
D
Daniel P. Berrange 已提交
1602 1603 1604 1605 1606 1607
      but a common set for fully virtualized domains are:
    </p>

    <dl>
      <dt><code>pae</code></dt>
      <dd>Physical address extension mode allows 32-bit guests
M
Matthew Booth 已提交
1608
        to address more than 4 GB of memory.</dd>
D
Daniel P. Berrange 已提交
1609 1610
      <dt><code>acpi</code></dt>
      <dd>ACPI is useful for power management, for example, with
M
Matthew Booth 已提交
1611
        KVM guests it is required for graceful shutdown to work.
D
Daniel P. Berrange 已提交
1612
      </dd>
1613 1614
      <dt><code>apic</code></dt>
      <dd>APIC allows the use of programmable IRQ
1615 1616 1617
      management. <span class="since">Since 0.10.2 (QEMU only)</span> there is
      an optional attribute <code>eoi</code> with values <code>on</code>
      and <code>off</code> which toggles the availability of EOI (End of
1618 1619
      Interrupt) for the guest.
      </dd>
J
Jim Fehlig 已提交
1620
      <dt><code>hap</code></dt>
1621 1622 1623 1624
      <dd>Depending on the <code>state</code> attribute (values <code>on</code>,
        <code>off</code>) enable or disable use of Hardware Assisted Paging.
        The default is <code>on</code> if the hypervisor detects availability
        of Hardware Assisted Paging.
J
Jim Fehlig 已提交
1625
      </dd>
1626 1627 1628 1629
      <dt><code>viridian</code></dt>
      <dd>Enable Viridian hypervisor extensions for paravirtualizing
        guest operating systems
      </dd>
1630 1631 1632 1633 1634 1635
      <dt><code>privnet</code></dt>
      <dd>Always create a private network namespace. This is
        automatically set if any interface devices are defined.
        This feature is only relevant for container based
        virtualization drivers, such as LXC.
      </dd>
1636 1637 1638 1639 1640 1641 1642 1643
      <dt><code>hyperv</code></dt>
      <dd>Enable various features improving behavior of guests
        running Microsoft Windows.
      <table class="top_table">
        <tr>
          <th>Feature</th>
          <th>Description</th>
          <th>Value</th>
1644
          <th>Since</th>
1645 1646 1647
        </tr>
        <tr>
          <td>relaxed</td>
1648
          <td>Relax constraints on timers</td>
1649
          <td> on, off</td>
1650
          <td><span class="since">1.0.0 (QEMU 2.0)</span></td>
1651 1652 1653 1654 1655
        </tr>
        <tr>
          <td>vapic</td>
          <td>Enable virtual APIC</td>
          <td>on, off</td>
1656
          <td><span class="since">1.1.0 (QEMU 2.0)</span></td>
1657 1658 1659 1660 1661
        </tr>
        <tr>
          <td>spinlocks</td>
          <td>Enable spinlock support</td>
          <td>on, off; retries - at least 4095</td>
1662
          <td><span class="since">1.1.0 (QEMU 2.0)</span></td>
1663
        </tr>
1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679
        <tr>
          <td>vpindex</td>
          <td>Virtual processor index</td>
          <td> on, off</td>
          <td><span class="since">1.3.3 (QEMU 2.5)</span></td>
        </tr>
        <tr>
          <td>runtime</td>
          <td>Processor time spent on running guest code and on behalf of guest code</td>
          <td> on, off</td>
          <td><span class="since">1.3.3 (QEMU 2.5)</span></td>
        </tr>
        <tr>
          <td>synic</td>
          <td>Enable Synthetic Interrupt Controller (SyNIC)</td>
          <td> on, off</td>
1680
          <td><span class="since">1.3.3 (QEMU 2.6)</span></td>
1681 1682 1683 1684 1685
        </tr>
        <tr>
          <td>stimer</td>
          <td>Enable SyNIC timers</td>
          <td> on, off</td>
1686
          <td><span class="since">1.3.3 (QEMU 2.6)</span></td>
1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699
        </tr>
        <tr>
          <td>reset</td>
          <td>Enable hypervisor reset</td>
          <td> on, off</td>
          <td><span class="since">1.3.3 (QEMU 2.5)</span></td>
        </tr>
        <tr>
          <td>vendor_id</td>
          <td>Set hypervisor vendor id</td>
          <td>on, off; value - string, up to 12 characters</td>
          <td><span class="since">1.3.3 (QEMU 2.5)</span></td>
        </tr>
1700 1701
      </table>
      </dd>
1702 1703 1704 1705 1706 1707
      <dt><code>pvspinlock</code></dt>
      <dd>Notify the guest that the host supports paravirtual spinlocks
          for example by exposing the pvticketlocks mechanism. This feature
          can be explicitly disabled by using <code>state='off'</code>
          attribute.
      </dd>
1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720
      <dt><code>kvm</code></dt>
      <dd>Various features to change the behavior of the KVM hypervisor.
      <table class="top_table">
        <tr>
          <th>Feature</th>
          <th>Description</th>
          <th>Value</th>
          <th>Since</th>
        </tr>
        <tr>
          <td>hidden</td>
          <td>Hide the KVM hypervisor from standard MSR based discovery</td>
          <td>on, off</td>
1721
          <td><span class="since">1.2.8 (QEMU 2.1.0)</span></td>
1722 1723 1724
        </tr>
      </table>
      </dd>
1725 1726 1727 1728 1729 1730
      <dt><code>pmu</code></dt>
      <dd>Depending on the <code>state</code> attribute (values <code>on</code>,
        <code>off</code>, default <code>on</code>) enable or disable the
        performance monitoring unit for the guest.
        <span class="since">Since 1.2.12</span>
      </dd>
1731 1732 1733
      <dt><code>vmport</code></dt>
      <dd>Depending on the <code>state</code> attribute (values <code>on</code>,
        <code>off</code>, default <code>on</code>) enable or disable
J
Ján Tomko 已提交
1734
        the emulation of VMware IO port, for vmmouse etc.
1735 1736
        <span class="since">Since 1.2.16</span>
      </dd>
M
Michal Privoznik 已提交
1737 1738 1739 1740 1741 1742
      <dt><code>gic</code></dt>
      <dd>Enable for architectures using a General Interrupt
          Controller instead of APIC in order to handle interrupts.
          For example, the 'aarch64' architecture uses
          <code>gic</code> instead of <code>apic</code>. The optional
          attribute <code>version</code> specifies the GIC version;
1743 1744 1745
          however, it may not be supported by all hypervisors. Accepted
          values are <code>2</code>, <code>3</code> and <code>host</code>.
          <span class="since">Since 1.2.16</span>
M
Michal Privoznik 已提交
1746
      </dd>
M
Michal Privoznik 已提交
1747 1748 1749 1750 1751 1752
      <dt><code>smm</code></dt>
      <dd>Enable System Management Mode. Possible values are
          <code>on</code> and <code>off</code>. The default is left
          for hypervisor to decide.
          <span class="since">Since 2.1.0</span>
      </dd>
D
Daniel P. Berrange 已提交
1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763
    </dl>

    <h3><a name="elementsTime">Time keeping</a></h3>

    <p>
      The guest clock is typically initialized from the host clock.
      Most operating systems expect the hardware clock to be kept
      in UTC, and this is the default. Windows, however, expects
      it to be in so called 'localtime'.
    </p>

1764
<pre>
1765 1766 1767 1768 1769 1770 1771 1772
...
&lt;clock offset='localtime'&gt;
  &lt;timer name='rtc' tickpolicy='catchup' track='guest'&gt;
    &lt;catchup threshold='123' slew='120' limit='10000'/&gt;
  &lt;/timer&gt;
  &lt;timer name='pit' tickpolicy='delay'/&gt;
&lt;/clock&gt;
...</pre>
D
Daniel P. Berrange 已提交
1773 1774 1775

    <dl>
      <dt><code>clock</code></dt>
1776
      <dd>
E
Eric Blake 已提交
1777 1778 1779 1780 1781 1782 1783 1784
        <p>The <code>offset</code> attribute takes four possible
          values, allowing fine grained control over how the guest
          clock is synchronized to the host. NB, not all hypervisors
          support all modes.</p>
        <dl>
          <dt><code>utc</code></dt>
          <dd>
            The guest clock will always be synchronized to UTC when
1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795
            booted.
            <span class="since">Since 0.9.11</span> 'utc' mode can be converted
            to 'variable' mode, which can be controlled by using the
            <code>adjustment</code> attribute. If the value is 'reset', the
            conversion is never done (not all hypervisors can
            synchronize to UTC on each boot; use of 'reset' will cause
            an error on those hypervisors). A numeric value
            forces the conversion to 'variable' mode using the value as the
            initial adjustment. The default <code>adjustment</code> is
            hypervisor specific.
          </dd>
E
Eric Blake 已提交
1796 1797 1798 1799
          <dt><code>localtime</code></dt>
          <dd>
            The guest clock will be synchronized to the host's configured
            timezone when booted, if any.
1800 1801
            <span class="since">Since 0.9.11,</span> the <code>adjustment</code>
            attribute behaves the same as in 'utc' mode.
E
Eric Blake 已提交
1802 1803 1804 1805 1806 1807 1808 1809 1810 1811
          </dd>
          <dt><code>timezone</code></dt>
          <dd>
            The guest clock will be synchronized to the requested timezone
            using the <code>timezone</code> attribute.
            <span class="since">Since 0.7.7</span>
          </dd>
          <dt><code>variable</code></dt>
          <dd>
            The guest clock will have an arbitrary offset applied
1812 1813
            relative to UTC or localtime, depending on the <code>basis</code>
            attribute. The delta relative to UTC (or localtime) is specified
E
Eric Blake 已提交
1814
            in seconds, using the <code>adjustment</code> attribute.
P
Philipp Hahn 已提交
1815
            The guest is free to adjust the RTC over time and expect
1816 1817 1818
            that it will be honored at next reboot. This is in
            contrast to 'utc' and 'localtime' mode (with the optional
            attribute adjustment='reset'), where the RTC adjustments are
E
Eric Blake 已提交
1819
            lost at each reboot. <span class="since">Since 0.7.7</span>
1820 1821
            <span class="since">Since 0.9.11</span> the <code>basis</code>
            attribute can be either 'utc' (default) or 'localtime'.
E
Eric Blake 已提交
1822 1823 1824 1825
          </dd>
        </dl>
        <p>
          A <code>clock</code> may have zero or more
1826
          <code>timer</code> sub-elements. <span class="since">Since
E
Eric Blake 已提交
1827 1828
          0.8.0</span>
        </p>
D
Daniel P. Berrange 已提交
1829
      </dd>
1830 1831
      <dt><code>timer</code></dt>
      <dd>
E
Eric Blake 已提交
1832 1833 1834 1835 1836 1837 1838 1839 1840 1841
        <p>
          Each timer element requires a <code>name</code> attribute,
          and has other optional attributes that depend on
          the <code>name</code> specified.  Various hypervisors
          support different combinations of attributes.
        </p>
        <dl>
          <dt><code>name</code></dt>
          <dd>
            The <code>name</code> attribute selects which timer is
1842 1843 1844
            being modified, and can be one of
            "platform" (currently unsupported),
            "hpet" (libxl, xen, qemu), "kvmclock" (qemu),
1845 1846 1847 1848 1849 1850 1851
            "pit" (qemu), "rtc" (qemu), "tsc" (libxl) or "hypervclock"
            (qemu - <span class="since">since 1.2.2</span>).

            The <code>hypervclock</code> timer adds support for the
            reference time counter and the reference page for iTSC
            feature for guests running the Microsoft Windows
            operating system.
E
Eric Blake 已提交
1852 1853 1854 1855 1856 1857 1858 1859 1860 1861
          </dd>
          <dt><code>track</code></dt>
          <dd>
            The <code>track</code> attribute specifies what the timer
            tracks, and can be "boot", "guest", or "wall".
            Only valid for <code>name="rtc"</code>
            or <code>name="platform"</code>.
          </dd>
          <dt><code>tickpolicy</code></dt>
          <dd>
1862 1863
            <p>
            The <code>tickpolicy</code> attribute determines what
1864
            happens when QEMU misses a deadline for injecting a
1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887
            tick to the guest:
            </p>
            <dl>
              <dt><code>delay</code></dt>
              <dd>Continue to deliver ticks at the normal rate.
                The guest time will be delayed due to the late
                tick</dd>
              <dt><code>catchup</code></dt>
              <dd>Deliver ticks at a higher rate to catch up
                with the missed tick. The guest time should
                not be delayed once catchup is complete.</dd>
              <dt><code>merge</code></dt>
              <dd>Merge the missed tick(s) into one tick and
                inject. The guest time may be delayed, depending
                on how the OS reacts to the merging of ticks</dd>
              <dt><code>discard</code></dt>
              <dd>Throw away the missed tick(s) and continue
                with future injection normally. The guest time
                may be delayed, unless the OS has explicit
                handling of lost ticks</dd>
            </dl>
            <p>If the policy is "catchup", there can be further details in
            the <code>catchup</code> sub-element.</p>
E
Eric Blake 已提交
1888 1889 1890 1891 1892 1893 1894 1895 1896
            <dl>
              <dt><code>catchup</code></dt>
              <dd>
                The <code>catchup</code> element has three optional
                attributes, each a positive integer.  The attributes
                are <code>threshold</code>, <code>slew</code>,
                and <code>limit</code>.
              </dd>
            </dl>
1897 1898 1899
            <p>
              Note that hypervisors are not required to support all policies across all time sources
            </p>
E
Eric Blake 已提交
1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919
          </dd>
          <dt><code>frequency</code></dt>
          <dd>
            The <code>frequency</code> attribute is an unsigned
            integer specifying the frequency at
            which <code>name="tsc"</code> runs.
          </dd>
          <dt><code>mode</code></dt>
          <dd>
            The <code>mode</code> attribute controls how
            the <code>name="tsc"</code> timer is managed, and can be
            "auto", "native", "emulate", "paravirt", or "smpsafe".
            Other timers are always emulated.
          </dd>
          <dt><code>present</code></dt>
          <dd>
            The <code>present</code> attribute can be "yes" or "no" to
            specify whether a particular timer is available to the guest.
          </dd>
        </dl>
1920
      </dd>
D
Daniel P. Berrange 已提交
1921 1922
    </dl>

1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934
    <h3><a name="elementsPerf">Performance monitoring events</a></h3>

    <p>
      Some platforms allow monitoring of performance of the virtual machine and
      the code executed inside. To enable the performance monitoring events
      you can either specify them in the <code>perf</code> element or enable
      them via <code>virDomainSetPerfEvents</code> API. The performance values
      are then retrieved using the virConnectGetAllDomainStats API.
      <span class="since">Since 2.0.0</span>
    </p>

<pre>
1935 1936 1937 1938 1939 1940 1941 1942 1943
...
&lt;perf&gt;
  &lt;event name='cmt' enabled='yes'/&gt;
  &lt;event name='mbmt' enabled='no'/&gt;
  &lt;event name='mbml' enabled='yes'/&gt;
  &lt;event name='cpu_cycles' enabled='no'/&gt;
  &lt;event name='instructions' enabled='yes'/&gt;
  &lt;event name='cache_references' enabled='no'/&gt;
  &lt;event name='cache_misses' enabled='no'/&gt;
1944
  &lt;event name='branch_instructions' enabled='no'/&gt;
1945
  &lt;event name='branch_misses' enabled='no'/&gt;
1946
  &lt;event name='bus_cycles' enabled='no'/&gt;
1947
  &lt;event name='stalled_cycles_frontend' enabled='no'/&gt;
1948
  &lt;event name='stalled_cycles_backend' enabled='no'/&gt;
1949
  &lt;event name='ref_cpu_cycles' enabled='no'/&gt;
1950
  &lt;event name='cpu_clock' enabled='no'/&gt;
1951
  &lt;event name='task_clock' enabled='no'/&gt;
1952
  &lt;event name='page_faults' enabled='no'/&gt;
1953
  &lt;event name='context_switches' enabled='no'/&gt;
1954
  &lt;event name='cpu_migrations' enabled='no'/&gt;
1955
  &lt;event name='page_faults_min' enabled='no'/&gt;
1956
  &lt;event name='page_faults_maj' enabled='no'/&gt;
1957
  &lt;event name='alignment_faults' enabled='no'/&gt;
1958
  &lt;event name='emulation_faults' enabled='no'/&gt;
1959 1960
&lt;/perf&gt;
...
1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983
</pre>

  <table class="top_table">
    <tr>
      <th>event name</th>
      <th>Description</th>
      <th>stats parameter name</th>
    </tr>
    <tr>
      <td><code>cmt</code></td>
      <td>usage of l3 cache in bytes by applications running on the platform</td>
      <td><code>perf.cmt</code></td>
    </tr>
    <tr>
      <td><code>mbmt</code></td>
      <td>total system bandwidth from one level of cache</td>
      <td><code>perf.mbmt</code></td>
    </tr>
    <tr>
      <td><code>mbml</code></td>
      <td>bandwidth of memory traffic for a memory controller</td>
      <td><code>perf.mbml</code></td>
    </tr>
Q
Qiaowei Ren 已提交
1984 1985
    <tr>
      <td><code>cpu_cycles</code></td>
1986
      <td>the count of cpu cycles (total/elapsed)</td>
Q
Qiaowei Ren 已提交
1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003
      <td><code>perf.cpu_cycles</code></td>
    </tr>
    <tr>
      <td><code>instructions</code></td>
      <td>the count of instructions by applications running on the platform</td>
      <td><code>perf.instructions</code></td>
    </tr>
    <tr>
      <td><code>cache_references</code></td>
      <td>the count of cache hits by applications running on the platform</td>
      <td><code>perf.cache_references</code></td>
    </tr>
    <tr>
      <td><code>cache_misses</code></td>
      <td>the count of cache misses by applications running on the platform</td>
      <td><code>perf.cache_misses</code></td>
    </tr>
2004 2005 2006 2007 2008
    <tr>
      <td><code>branch_instructions</code></td>
      <td>the count of branch instructions by applications running on the platform</td>
      <td><code>perf.branch_instructions</code></td>
    </tr>
2009 2010 2011 2012 2013
    <tr>
      <td><code>branch_misses</code></td>
      <td>the count of branch misses by applications running on the platform</td>
      <td><code>perf.branch_misses</code></td>
    </tr>
2014 2015 2016 2017 2018
    <tr>
      <td><code>bus_cycles</code></td>
      <td>the count of bus cycles by applications running on the platform</td>
      <td><code>perf.bus_cycles</code></td>
    </tr>
2019 2020 2021 2022 2023 2024
    <tr>
      <td><code>stalled_cycles_frontend</code></td>
      <td>the count of stalled cpu cycles in the frontend of the instruction
          processor pipeline by applications running on the platform</td>
      <td><code>perf.stalled_cycles_frontend</code></td>
    </tr>
2025 2026 2027 2028 2029 2030
    <tr>
      <td><code>stalled_cycles_backend</code></td>
      <td>the count of stalled cpu cycles in the backend of the instruction
          processor pipeline by applications running on the platform</td>
      <td><code>perf.stalled_cycles_backend</code></td>
    </tr>
2031 2032 2033 2034 2035 2036
    <tr>
      <td><code>ref_cpu_cycles</code></td>
      <td>the count of total cpu cycles not affected by CPU frequency scaling
         by applications running on the platform</td>
      <td><code>perf.ref_cpu_cycles</code></td>
    </tr>
2037 2038 2039 2040 2041 2042 2043
    <tr>
      <td><code>cpu_clock</code></td>
      <td>the count of cpu clock time, as measured by a monotonic
          high-resolution per-CPU timer, by applications running on
          the platform</td>
      <td><code>perf.cpu_clock</code></td>
    </tr>
2044 2045 2046 2047 2048 2049 2050
    <tr>
      <td><code>task_clock</code></td>
      <td>the count of task clock time, as measured by a monotonic
          high-resolution CPU timer, specific to the task that
          is run by applications running on the platform</td>
      <td><code>perf.task_clock</code></td>
    </tr>
2051 2052 2053 2054 2055 2056 2057
    <tr>
      <td><code>page_faults</code></td>
      <td>the count of page faults by applications running on the
          platform. This includes minor, major, invalid and other
          types of page faults</td>
      <td><code>perf.page_faults</code></td>
    </tr>
2058 2059 2060 2061 2062 2063
    <tr>
      <td><code>context_switches</code></td>
      <td>the count of context switches by applications running on
          the platform</td>
      <td><code>perf.context_switches</code></td>
    </tr>
2064 2065 2066 2067 2068 2069 2070
    <tr>
      <td><code>cpu_migrations</code></td>
      <td>the count of cpu migrations, that is, where the process
          moved from one logical processor to another, by
          applications running on the platform</td>
      <td><code>perf.cpu_migrations</code></td>
    </tr>
2071 2072 2073 2074 2075 2076 2077 2078
    <tr>
      <td><code>page_faults_min</code></td>
      <td>the count of minor page faults, that is, where the
          page was present in the page cache, and therefore
          the fault avoided loading it from storage, by
          applications running on the platform</td>
      <td><code>perf.page_faults_min</code></td>
    </tr>
2079 2080 2081 2082 2083 2084 2085 2086
    <tr>
      <td><code>page_faults_maj</code></td>
      <td>the count of major page faults, that is, where the
          page was not present in the page cache, and
          therefore had to be fetched from storage, by
          applications running on the platform</td>
      <td><code>perf.page_faults_maj</code></td>
    </tr>
2087 2088 2089 2090 2091 2092 2093
    <tr>
      <td><code>alignment_faults</code></td>
      <td>the count of alignment faults, that is when
          the load or store is not aligned properly, by
          applications running on the platform</td>
      <td><code>perf.alignment_faults</code></td>
    </tr>
2094 2095 2096 2097 2098 2099 2100 2101
    <tr>
      <td><code>emulation_faults</code></td>
      <td>the count of emulation faults, that is when
          the kernel traps on unimplemented instrucions
          and emulates them for user space, by
          applications running on the platform</td>
      <td><code>perf.emulation_faults</code></td>
    </tr>
2102 2103
  </table>

D
Daniel P. Berrange 已提交
2104 2105 2106
    <h3><a name="elementsDevices">Devices</a></h3>

    <p>
A
Atsushi SAKAI 已提交
2107
      The final set of XML elements are all used to describe devices
D
Daniel P. Berrange 已提交
2108 2109 2110 2111 2112
      provided to the guest domain. All devices occur as children
      of the main <code>devices</code> element.
      <span class="since">Since 0.1.3</span>
    </p>

2113
<pre>
2114 2115 2116 2117 2118
...
&lt;devices&gt;
  &lt;emulator&gt;/usr/lib/xen/bin/qemu-dm&lt;/emulator&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
2119 2120 2121 2122

    <dl>
      <dt><code>emulator</code></dt>
      <dd>
M
Matthew Booth 已提交
2123 2124 2125 2126 2127
        The contents of the <code>emulator</code> element specify
        the fully qualified path to the device model emulator binary.
        The <a href="formatcaps.html">capabilities XML</a> specifies
        the recommended default emulator to use for each particular
        domain type / architecture combination.
D
Daniel P. Berrange 已提交
2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138
      </dd>
    </dl>

    <h4><a name="elementsDisks">Hard drives, floppy disks, CDROMs</a></h4>

    <p>
      Any device that looks like a disk, be it a floppy, harddisk,
      cdrom, or paravirtualized driver is specified via the <code>disk</code>
      element.
    </p>

2139
<pre>
2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154
...
&lt;devices&gt;
  &lt;disk type='file' snapshot='external'&gt;
    &lt;driver name="tap" type="aio" cache="default"/&gt;
    &lt;source file='/var/lib/xen/images/fv0' startupPolicy='optional'&gt;
      &lt;seclabel relabel='no'/&gt;
    &lt;/source&gt;
    &lt;target dev='hda' bus='ide'/&gt;
    &lt;iotune&gt;
      &lt;total_bytes_sec&gt;10000000&lt;/total_bytes_sec&gt;
      &lt;read_iops_sec&gt;400000&lt;/read_iops_sec&gt;
      &lt;write_iops_sec&gt;100000&lt;/write_iops_sec&gt;
    &lt;/iotune&gt;
    &lt;boot order='2'/&gt;
    &lt;encryption type='...'&gt;
M
MORITA Kazutaka 已提交
2155
      ...
2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293
    &lt;/encryption&gt;
    &lt;shareable/&gt;
    &lt;serial&gt;
      ...
    &lt;/serial&gt;
  &lt;/disk&gt;
    ...
  &lt;disk type='network'&gt;
    &lt;driver name="qemu" type="raw" io="threads" ioeventfd="on" event_idx="off"/&gt;
    &lt;source protocol="sheepdog" name="image_name"&gt;
      &lt;host name="hostname" port="7000"/&gt;
    &lt;/source&gt;
    &lt;target dev="hdb" bus="ide"/&gt;
    &lt;boot order='1'/&gt;
    &lt;transient/&gt;
    &lt;address type='drive' controller='0' bus='1' unit='0'/&gt;
  &lt;/disk&gt;
  &lt;disk type='network'&gt;
    &lt;driver name="qemu" type="raw"/&gt;
    &lt;source protocol="rbd" name="image_name2"&gt;
      &lt;host name="hostname" port="7000"/&gt;
      &lt;snapshot name="snapname"/&gt;
      &lt;config file="/path/to/file"/&gt;
    &lt;/source&gt;
    &lt;target dev="hdc" bus="ide"/&gt;
    &lt;auth username='myuser'&gt;
      &lt;secret type='ceph' usage='mypassid'/&gt;
    &lt;/auth&gt;
  &lt;/disk&gt;
  &lt;disk type='block' device='cdrom'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;target dev='hdd' bus='ide' tray='open'/&gt;
    &lt;readonly/&gt;
  &lt;/disk&gt;
  &lt;disk type='network' device='cdrom'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source protocol="http" name="url_path"&gt;
      &lt;host name="hostname" port="80"/&gt;
    &lt;/source&gt;
    &lt;target dev='hde' bus='ide' tray='open'/&gt;
    &lt;readonly/&gt;
  &lt;/disk&gt;
  &lt;disk type='network' device='cdrom'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source protocol="https" name="url_path"&gt;
      &lt;host name="hostname" port="443"/&gt;
    &lt;/source&gt;
    &lt;target dev='hdf' bus='ide' tray='open'/&gt;
    &lt;readonly/&gt;
  &lt;/disk&gt;
  &lt;disk type='network' device='cdrom'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source protocol="ftp" name="url_path"&gt;
      &lt;host name="hostname" port="21"/&gt;
    &lt;/source&gt;
    &lt;target dev='hdg' bus='ide' tray='open'/&gt;
    &lt;readonly/&gt;
  &lt;/disk&gt;
  &lt;disk type='network' device='cdrom'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source protocol="ftps" name="url_path"&gt;
      &lt;host name="hostname" port="990"/&gt;
    &lt;/source&gt;
    &lt;target dev='hdh' bus='ide' tray='open'/&gt;
    &lt;readonly/&gt;
  &lt;/disk&gt;
  &lt;disk type='network' device='cdrom'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source protocol="tftp" name="url_path"&gt;
      &lt;host name="hostname" port="69"/&gt;
    &lt;/source&gt;
    &lt;target dev='hdi' bus='ide' tray='open'/&gt;
    &lt;readonly/&gt;
  &lt;/disk&gt;
  &lt;disk type='block' device='lun'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source dev='/dev/sda'/&gt;
    &lt;target dev='sda' bus='scsi'/&gt;
    &lt;address type='drive' controller='0' bus='0' target='3' unit='0'/&gt;
  &lt;/disk&gt;
  &lt;disk type='block' device='disk'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source dev='/dev/sda'/&gt;
    &lt;geometry cyls='16383' heads='16' secs='63' trans='lba'/&gt;
    &lt;blockio logical_block_size='512' physical_block_size='4096'/&gt;
    &lt;target dev='hdj' bus='ide'/&gt;
  &lt;/disk&gt;
  &lt;disk type='volume' device='disk'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source pool='blk-pool0' volume='blk-pool0-vol0'/&gt;
    &lt;target dev='hdk' bus='ide'/&gt;
  &lt;/disk&gt;
  &lt;disk type='network' device='disk'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source protocol='iscsi' name='iqn.2013-07.com.example:iscsi-nopool/2'&gt;
      &lt;host name='example.com' port='3260'/&gt;
    &lt;/source&gt;
    &lt;auth username='myuser'&gt;
      &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
    &lt;/auth&gt;
    &lt;target dev='vda' bus='virtio'/&gt;
  &lt;/disk&gt;
  &lt;disk type='network' device='lun'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source protocol='iscsi' name='iqn.2013-07.com.example:iscsi-nopool/1'&gt;
      &lt;host name='example.com' port='3260'/&gt;
    &lt;/source&gt;
    &lt;auth username='myuser'&gt;
      &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
    &lt;/auth&gt;
    &lt;target dev='sdb' bus='scsi'/&gt;
  &lt;/disk&gt;
  &lt;disk type='volume' device='disk'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source pool='iscsi-pool' volume='unit:0:0:1' mode='host'/&gt;
    &lt;auth username='myuser'&gt;
      &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
    &lt;/auth&gt;
    &lt;target dev='vdb' bus='virtio'/&gt;
  &lt;/disk&gt;
  &lt;disk type='volume' device='disk'&gt;
    &lt;driver name='qemu' type='raw'/&gt;
    &lt;source pool='iscsi-pool' volume='unit:0:0:2' mode='direct'/&gt;
    &lt;auth username='myuser'&gt;
      &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
    &lt;/auth&gt;
    &lt;target dev='vdc' bus='virtio'/&gt;
  &lt;/disk&gt;
  &lt;disk type='file' device='disk'&gt;
    &lt;driver name='qemu' type='qcow2'/&gt;
    &lt;source file='/var/lib/libvirt/images/domain.qcow'/&gt;
    &lt;backingStore type='file'&gt;
      &lt;format type='qcow2'/&gt;
      &lt;source file='/var/lib/libvirt/images/snapshot.qcow'/&gt;
      &lt;backingStore type='block'&gt;
        &lt;format type='raw'/&gt;
        &lt;source dev='/dev/mapper/base'/&gt;
        &lt;backingStore/&gt;
2294
      &lt;/backingStore&gt;
2295 2296 2297 2298 2299
    &lt;/backingStore&gt;
    &lt;target dev='vdd' bus='virtio'/&gt;
  &lt;/disk&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
2300 2301 2302

    <dl>
      <dt><code>disk</code></dt>
2303 2304
      <dd>The <code>disk</code> element is the main container for
      describing disks and supports the following attributes:
2305
        <dl>
2306
          <dt><code>type</code></dt>
2307 2308 2309 2310 2311 2312
            <dd>
            Valid values are "file", "block",
            "dir" (<span class="since">since 0.7.5</span>),
            "network" (<span class="since">since 0.8.7</span>), or
            "volume" (<span class="since">since 1.0.5</span>)
            and refer to the underlying source for the disk.
2313
            <span class="since">Since 0.0.3</span>
2314
            </dd>
2315
          <dt><code>device</code></dt>
2316 2317 2318 2319 2320 2321
            <dd>
            Indicates how the disk is to be exposed to the guest OS. Possible
            values for this attribute are "floppy", "disk", "cdrom", and "lun",
            defaulting to "disk".
            <p>
            Using "lun" (<span class="since">since 0.9.10</span>) is only
2322 2323
            valid when the <code>type</code> is "block" or "network" for
            <code>protocol='iscsi'</code> or when the <code>type</code>
2324
            is "volume" when using an iSCSI source <code>pool</code>
2325 2326 2327
            for <code>mode</code> "host" or as an
            <a href="http://wiki.libvirt.org/page/NPIV_in_libvirt">NPIV</a>
            virtual Host Bus Adapter (vHBA) using a Fibre Channel storage pool.
2328
            Configured in this manner, the LUN behaves identically to "disk",
2329 2330 2331 2332 2333 2334
            except that generic SCSI commands from the guest are accepted
            and passed through to the physical device. Also note that
            device='lun' will only be recognized for actual raw devices,
            but never for individual partitions or LVM partitions (in those
            cases, the kernel will reject the generic SCSI commands, making
            it identical to device='disk').
2335
            <span class="since">Since 0.1.4</span>
2336 2337
            </p>
            </dd>
2338
          <dt><code>rawio</code></dt>
2339
            <dd>
2340
            Indicates whether the disk needs rawio capability. Valid
2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351
            settings are "yes" or "no" (default is "no"). If any one disk
            in a domain has rawio='yes', rawio capability will be enabled
            for all disks in the domain (because, in the case of QEMU, this
            capability can only be set on a per-process basis). This attribute
            is only valid when device is "lun". NB, <code>rawio</code> intends
            to confine the capability per-device, however, current QEMU
            implementation gives the domain process broader capability
            than that (per-process basis, affects all the domain disks).
            To confine the capability as much as possible for QEMU driver
            as this stage, <code>sgio</code> is recommended, it's more
            secure than <code>rawio</code>.
2352
            <span class="since">Since 0.9.10</span>
2353
            </dd>
2354
          <dt><code>sgio</code></dt>
2355
            <dd>
2356 2357 2358 2359
            If supported by the hypervisor and OS, indicates whether
            unprivileged SG_IO commands are filtered for the disk. Valid
            settings are "filtered" or "unfiltered" where the default is
            "filtered". Only available when the <code>device</code> is 'lun'.
2360
            <span class="since">Since 1.0.2</span>
2361
            </dd>
2362
          <dt><code>snapshot</code></dt>
2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375
            <dd>
            Indicates the default behavior of the disk during disk snapshots:
            "internal" requires a file format such as qcow2 that can store
            both the snapshot and the data changes since the snapshot;
            "external" will separate the snapshot from the live data; and
            "no" means the disk will not participate in snapshots. Read-only
            disks default to "no", while the default for other disks depends
            on the hypervisor's capabilities.  Some hypervisors allow a
            per-snapshot choice as well, during
            <a href="formatsnapshot.html">domain snapshot creation</a>.
            Not all snapshot modes are supported; for example,
            <code>snapshot='yes'</code> with a transient disk generally
            does not make sense.
2376
            <span class="since">Since 0.9.5</span>
2377 2378 2379
            </dd>
        </dl>
      </dd>
D
Daniel P. Berrange 已提交
2380
      <dt><code>source</code></dt>
2381 2382 2383
      <dd>Representation of the disk <code>source</code> depends on the
      disk <code>type</code> attribute value as follows:
          <dl>
2384
            <dt><code>file</code></dt>
2385 2386 2387
              <dd>
              The <code>file</code> attribute specifies the fully-qualified
              path to the file holding the disk.
2388
              <span class="since">Since 0.0.3</span>
2389
              </dd>
2390
            <dt><code>block</code></dt>
2391
              <dd>
2392 2393
              The <code>dev</code> attribute specifies the fully-qualified path
              to the host device to serve as the disk.
2394
              <span class="since">Since 0.0.3</span>
2395
              </dd>
2396
            <dt><code>dir</code></dt>
2397 2398 2399
              <dd>
              The <code>dir</code> attribute specifies the fully-qualified path
              to the directory to use as the disk.
2400
              <span class="since">Since 0.7.5</span>
2401
              </dd>
2402
            <dt><code>network</code></dt>
2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415
              <dd>
              The <code>protocol</code> attribute specifies the protocol to
              access to the requested image. Possible values are "nbd",
              "iscsi", "rbd", "sheepdog" or "gluster".  If the
              <code>protocol</code> attribute is "rbd", "sheepdog" or
              "gluster", an additional attribute <code>name</code> is
              mandatory to specify which volume/image will be used. For "nbd",
              the <code>name</code> attribute is optional. For "iscsi"
              (<span class="since">since 1.0.4</span>), the <code>name</code>
              attribute may include a logical unit number, separated from the
              target's name by a slash (e.g.,
              <code>iqn.2013-07.com.example:iscsi-pool/1</code>). If not
              specified, the default LUN is zero.
2416
              <span class="since">Since 0.8.7</span>
2417
              </dd>
2418
            <dt><code>volume</code></dt>
2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444
              <dd>
              The underlying disk source is represented by attributes
              <code>pool</code> and <code>volume</code>. Attribute
              <code>pool</code> specifies the name of the
              <a href="formatstorage.html">storage pool</a> (managed
              by libvirt) where the disk source resides. Attribute
              <code>volume</code> specifies the name of storage volume (managed
              by libvirt) used as the disk source. The value for the
              <code>volume</code> attribute will be the output from the "Name"
              column of a <code>virsh vol-list [pool-name]</code> command.
              <p>
              Use the attribute <code>mode</code>
              (<span class="since">since 1.1.1</span>) to indicate how to
              represent the LUN as the disk source. Valid values are
              "direct" and "host". If <code>mode</code> is not specified,
              the default is to use "host".

              Using "direct" as the <code>mode</code> value indicates to use
              the <a href="formatstorage.html">storage pool's</a>
              <code>source</code> element <code>host</code> attribute as
              the disk source to generate the libiscsi URI (e.g.
              'file=iscsi://example.com:3260/iqn.2013-07.com.example:iscsi-pool/1').

              Using "host" as the <code>mode</code> value indicates to use the
              LUN's path as it shows up on host (e.g.
              'file=/dev/disk/by-path/ip-example.com:3260-iscsi-iqn.2013-07.com.example:iscsi-pool-lun-1').
2445 2446 2447

              Using a LUN from an iSCSI source pool provides the same
              features as a <code>disk</code> configured using
2448
              <code>type</code> 'block' or 'network' and <code>device</code>
2449
              of 'lun' with respect to how the LUN is presented to and
2450
              may be used by the guest.
2451

2452
              <span class="since">Since 1.0.5</span>
2453 2454 2455 2456
              </p>
              </dd>
          </dl>
        With "file", "block", and "volume", one or more optional
2457
        sub-elements <code>seclabel</code>, <a href="#seclabel">described
2458 2459
        below</a> (and <span class="since">since 0.9.9</span>), can be
        used to override the domain security labeling policy for just
2460 2461
        that source file. (NB, for "volume" type disk, <code>seclabel</code>
        is only valid when the specified storage volume is of 'file' or
2462 2463
        'block' type).
        <p>
2464
        The <code>source</code> element may contain the following sub elements:
2465
        </p>
2466 2467 2468 2469 2470

        <dl>
          <dt><code>host</code></dt>
          <dd>
            <p>
2471 2472 2473 2474
            When the disk <code>type</code> is "network", the <code>source</code>
            may have zero or more <code>host</code> sub-elements used to
            specify the hosts to connect.

2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503
            The <code>host</code> element supports 4 attributes, viz.  "name",
            "port", "transport" and "socket", which specify the hostname,
            the port number, transport type and path to socket, respectively.
            The meaning of this element and the number of the elements depend
            on the protocol attribute.
            </p>
            <table class="top_table">
              <tr>
                <th> Protocol </th>
                <th> Meaning </th>
                <th> Number of hosts </th>
                <th> Default port </th>
              </tr>
              <tr>
                <td> nbd </td>
                <td> a server running nbd-server </td>
                <td> only one </td>
                <td> 10809 </td>
              </tr>
              <tr>
                <td> iscsi </td>
                <td> an iSCSI server </td>
                <td> only one </td>
                <td> 3260 </td>
              </tr>
              <tr>
                <td> rbd </td>
                <td> monitor servers of RBD </td>
                <td> one or more </td>
2504
                <td> librados default </td>
2505 2506 2507 2508 2509 2510 2511 2512 2513 2514
              </tr>
              <tr>
                <td> sheepdog </td>
                <td> one of the sheepdog servers (default is localhost:7000) </td>
                <td> zero or one </td>
                <td> 7000 </td>
              </tr>
              <tr>
                <td> gluster </td>
                <td> a server running glusterd daemon </td>
2515
                <td> one or more (<span class="since">Since 2.1.0</span>), just one prior to that </td>
2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526
                <td> 24007 </td>
              </tr>
            </table>
            <p>
            gluster supports "tcp", "rdma", "unix" as valid values for the
            transport attribute.  nbd supports "tcp" and "unix".  Others only
            support "tcp".  If nothing is specified, "tcp" is assumed. If the
            transport is "unix", the socket attribute specifies the path to an
            AF_UNIX socket.
            </p>
          </dd>
2527 2528 2529 2530 2531 2532 2533
          <dt><code>snapshot</code></dt>
          <dd>
            The <code>name</code> attribute of <code>snapshot</code> element can
            optionally specify an internal snapshot name to be used as the
            source for storage protocols.
            Supported for 'rbd' <span class="since">since 1.2.11 (QEMU only).</span>
          </dd>
2534 2535 2536 2537 2538 2539 2540 2541
          <dt><code>config</code></dt>
          <dd>
            The <code>file</code> attribute for the <code>config</code> element
            provides a fully qualified path to a configuration file to be
            provided as a parameter to the client of a networked storage
            protocol. Supported for 'rbd' <span class="since">since 1.2.11
            (QEMU only).</span>
          </dd>
2542 2543
        </dl>

2544
        <p>
2545
        For a "file" or "volume" disk type which represents a cdrom or floppy
2546 2547
        (the <code>device</code> attribute), it is possible to define
        policy what to do with the disk if the source file is not accessible.
2548 2549
        (NB, <code>startupPolicy</code> is not valid for "volume" disk unless
         the specified storage volume is of "file" type). This is done by the
2550 2551
        <code>startupPolicy</code> attribute
        (<span class="since">since 0.9.7</span>),
2552
        accepting these values:
2553
        </p>
2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568
        <table class="top_table">
          <tr>
            <td> mandatory </td>
            <td> fail if missing for any reason (the default) </td>
          </tr>
          <tr>
            <td> requisite </td>
            <td> fail if missing on boot up,
                 drop if missing on migrate/restore/revert </td>
          </tr>
          <tr>
            <td> optional </td>
            <td> drop if missing at any start attempt </td>
          </tr>
        </table>
2569 2570 2571 2572 2573 2574 2575
        <p>
        <span class="since">Since 1.1.2</span> the <code>startupPolicy</code>
        is extended to support hard disks besides cdrom and floppy. On guest
        cold bootup, if a certain disk is not accessible or its disk chain is
        broken, with startupPolicy 'optional' the guest will drop this disk.
        This feature doesn't support migration currently.
        </p>
2576
        </dd>
2577 2578
      <dt><code>backingStore</code></dt>
      <dd>
D
Deepak Shetty 已提交
2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592
        This element describes the backing store used by the disk
        specified by sibling <code>source</code> element. It is
        currently ignored on input and only used for output to
        describe the detected backing chains of running
        domains <span class="since">since 1.2.4</span> (although a
        future version of libvirt may start accepting chains on input,
        or output information for offline domains). An
        empty <code>backingStore</code> element means the sibling
        source is self-contained and is not based on any backing
        store. For backing chain information to be accurate, the
        backing format must be correctly specified in the metadata of
        each file of the chain (files created by libvirt satisfy this
        property, but using existing external files for snapshot or
        block copy operations requires the end user to pre-create the
2593
        file correctly). The following attributes are
D
Deepak Shetty 已提交
2594
        supported in <code>backingStore</code>:
2595
        <dl>
2596
          <dt><code>type</code></dt>
2597 2598 2599 2600 2601
          <dd>
            The <code>type</code> attribute represents the type of disk used
            by the backing store, see disk type attribute above for more
            details and possible values.
          </dd>
2602
          <dt><code>index</code></dt>
2603 2604 2605 2606 2607 2608 2609 2610
          <dd>
            This attribute is only valid in output (and ignored on input) and
            it can be used to refer to a specific part of the disk chain when
            doing block operations (such as via the
            <code>virDomainBlockRebase</code> API). For example,
            <code>vda[2]</code> refers to the backing store with
            <code>index='2'</code> of the disk with <code>vda</code> target.
          </dd>
2611 2612 2613 2614
        </dl>
        Moreover, <code>backingStore</code> supports the following sub-elements:
        <dl>
          <dt><code>format</code></dt>
2615 2616 2617 2618 2619
          <dd>
            The <code>format</code> element contains <code>type</code>
            attribute which specifies the internal format of the backing
            store, such as <code>raw</code> or <code>qcow2</code>.
          </dd>
2620
          <dt><code>source</code></dt>
2621 2622 2623 2624 2625 2626
          <dd>
            This element has the same structure as the <code>source</code>
            element in <code>disk</code>. It specifies which file, device,
            or network location contains the data of the described backing
            store.
          </dd>
2627
          <dt><code>backingStore</code></dt>
2628 2629 2630 2631 2632 2633 2634
          <dd>
            If the backing store is not self-contained, the next element
            in the chain is described by nested <code>backingStore</code>
            element.
          </dd>
        </dl>
      </dd>
2635 2636
      <dt><code>mirror</code></dt>
      <dd>
E
Eric Blake 已提交
2637 2638 2639 2640
        This element is present if the hypervisor has started a
        long-running block job operation, where the mirror location in
        the <code>source</code> sub-element will eventually have the
        same contents as the source, and with the file format in the
E
Eric Blake 已提交
2641 2642 2643 2644
        sub-element <code>format</code> (which might differ from the
        format of the source).  The details of the <code>source</code>
        sub-element are determined by the <code>type</code> attribute
        of the mirror, similar to what is done for the
E
Eric Blake 已提交
2645 2646 2647 2648 2649
        overall <code>disk</code> device element. The <code>job</code>
        attribute mentions which API started the operation ("copy" for
        the <code>virDomainBlockRebase</code> API, or "active-commit"
        for the <code>virDomainBlockCommit</code>
        API), <span class="since">since 1.2.7</span>.  The
2650 2651 2652 2653 2654 2655
        attribute <code>ready</code>, if present, tracks progress of
        the job: <code>yes</code> if the disk is known to be ready to
        pivot, or, <span class="since">since
        1.2.7</span>, <code>abort</code> or <code>pivot</code> if the
        job is in the process of completing.  If <code>ready</code> is
        not present, the disk is probably still
2656
        copying.  For now, this element only valid in output; it is
2657 2658 2659 2660 2661 2662 2663
        ignored on input.  The <code>source</code> sub-element exists
        for all two-phase jobs <span class="since">since 1.2.6</span>.
        Older libvirt supported only block copy to a
        file, <span class="since">since 0.9.12</span>; for
        compatibility with older clients, such jobs include redundant
        information in the attributes <code>file</code>
        and <code>format</code> in the <code>mirror</code> element.
2664
      </dd>
D
Daniel P. Berrange 已提交
2665
      <dt><code>target</code></dt>
E
Eric Blake 已提交
2666 2667 2668 2669 2670 2671 2672 2673
      <dd>The <code>target</code> element controls the bus / device
        under which the disk is exposed to the guest
        OS. The <code>dev</code> attribute indicates the "logical"
        device name. The actual device name specified is not
        guaranteed to map to the device name in the guest OS. Treat it
        as a device ordering hint.  The optional <code>bus</code>
        attribute specifies the type of disk device to emulate;
        possible values are driver specific, with typical values being
2674 2675
        "ide", "scsi", "virtio", "xen", "usb", "sata", or
        "sd" <span class="since">"sd" since 1.1.2</span>. If omitted, the bus
M
Martin Kletzander 已提交
2676 2677
        type is inferred from the style of the device name (e.g. a device named
        'sda' will typically be exported using a SCSI bus). The optional
2678 2679 2680 2681
        attribute <code>tray</code> indicates the tray status of the
        removable disks (i.e. CDROM or Floppy disk), the value can be either
        "open" or "closed", defaults to "closed". NB, the value of
        <code>tray</code> could be updated while the domain is running.
2682 2683 2684 2685
        The optional attribute <code>removable</code> sets the
        removable flag for USB disks, and its value can be either "on"
        or "off", defaulting to "off". <span class="since">Since
        0.0.3; <code>bus</code> attribute since 0.4.3;
2686
        <code>tray</code> attribute since 0.9.11; "usb" attribute value since
2687 2688
        after 0.4.4; "sata" attribute value since 0.9.7; "removable" attribute
        value since 1.1.3</span>
2689
      </dd>
L
Lei Li 已提交
2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722
      <dt><code>iotune</code></dt>
      <dd>The optional <code>iotune</code> element provides the
        ability to provide additional per-device I/O tuning, with
        values that can vary for each device (contrast this to
        the <a href="#elementsBlockTuning"><code>&lt;blkiotune&gt;</code></a>
        element, which applies globally to the domain).  Currently,
        the only tuning available is Block I/O throttling for qemu.
        This element has optional sub-elements; any sub-element not
        specified or given with a value of 0 implies no
        limit.  <span class="since">Since 0.9.8</span>
        <dl>
          <dt><code>total_bytes_sec</code></dt>
          <dd>The optional <code>total_bytes_sec</code> element is the
            total throughput limit in bytes per second.  This cannot
            appear with <code>read_bytes_sec</code>
            or <code>write_bytes_sec</code>.</dd>
          <dt><code>read_bytes_sec</code></dt>
          <dd>The optional <code>read_bytes_sec</code> element is the
            read throughput limit in bytes per second.</dd>
          <dt><code>write_bytes_sec</code></dt>
          <dd>The optional <code>write_bytes_sec</code> element is the
            write throughput limit in bytes per second.</dd>
          <dt><code>total_iops_sec</code></dt>
          <dd>The optional <code>total_iops_sec</code> element is the
            total I/O operations per second.  This cannot
            appear with <code>read_iops_sec</code>
            or <code>write_iops_sec</code>.</dd>
          <dt><code>read_iops_sec</code></dt>
          <dd>The optional <code>read_iops_sec</code> element is the
            read I/O operations per second.</dd>
          <dt><code>write_iops_sec</code></dt>
          <dd>The optional <code>write_iops_sec</code> element is the
            write I/O operations per second.</dd>
2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746
          <dt><code>total_bytes_sec_max</code></dt>
          <dd>The optional <code>total_bytes_sec_max</code> element is the
            maximum total throughput limit in bytes per second.  This cannot
            appear with <code>read_bytes_sec_max</code>
            or <code>write_bytes_sec_max</code>.</dd>
          <dt><code>read_bytes_sec_max</code></dt>
          <dd>The optional <code>read_bytes_sec_max</code> element is the
            maximum read throughput limit in bytes per second.</dd>
          <dt><code>write_bytes_sec_max</code></dt>
          <dd>The optional <code>write_bytes_sec_max</code> element is the
            maximum write throughput limit in bytes per second.</dd>
          <dt><code>total_iops_sec_max</code></dt>
          <dd>The optional <code>total_iops_sec_max</code> element is the
            maximum total I/O operations per second.  This cannot
            appear with <code>read_iops_sec_max</code>
            or <code>write_iops_sec_max</code>.</dd>
          <dt><code>read_iops_sec_max</code></dt>
          <dd>The optional <code>read_iops_sec_max</code> element is the
            maximum read I/O operations per second.</dd>
          <dt><code>write_iops_sec_max</code></dt>
          <dd>The optional <code>write_iops_sec_max</code> element is the
            maximum write I/O operations per second.</dd>
          <dt><code>size_iops_sec</code></dt>
          <dd>The optional <code>size_iops_sec</code> element is the
2747 2748 2749 2750 2751
            size of I/O operations per second.
          <p>
            <span class="since">Throughput limits since 1.2.11 and QEMU 1.7</span>
          </p>
          </dd>
2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762
          <dt><code>group_name</code></dt>
          <dd>The optional <code>group_name</code> provides the cability
            to share I/O throttling quota between multiple drives. This
            prevents end-users from circumventing a hosting provider's
            throttling policy by splitting 1 large drive in N small drives
            and getting N times the normal throttling quota. Any name may
            be used.
          <p>
            <span class="since">group_name since 3.0.0 and QEMU 2.4</span>
          </p>
          </dd>
2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796
          <dt><code>total_bytes_sec_max_length</code></dt>
          <dd>The optional <code>total_bytes_sec_max_length</code>
            element is the maximum duration in seconds for the
            <code>total_bytes_sec_max</code> burst period. Only valid
            when the <code>total_bytes_sec_max</code> is set.</dd>
          <dt><code>read_bytes_sec_max_length</code></dt>
          <dd>The optional <code>read_bytes_sec_max_length</code>
            element is the maximum duration in seconds for the
            <code>read_bytes_sec_max</code> burst period. Only valid
            when the <code>read_bytes_sec_max</code> is set.</dd>
          <dt><code>write_bytes_sec_max</code></dt>
          <dd>The optional <code>write_bytes_sec_max_length</code>
            element is the maximum duration in seconds for the
            <code>write_bytes_sec_max</code> burst period. Only valid
            when the <code>write_bytes_sec_max</code> is set.</dd>
          <dt><code>total_iops_sec_max_length</code></dt>
          <dd>The optional <code>total_iops_sec_max_length</code>
            element is the maximum duration in seconds for the
            <code>total_iops_sec_max</code> burst period. Only valid
            when the <code>total_iops_sec_max</code> is set.</dd>
          <dt><code>read_iops_sec_max_length</code></dt>
          <dd>The optional <code>read_iops_sec_max_length</code>
            element is the maximum duration in seconds for the
            <code>read_iops_sec_max</code> burst period. Only valid
            when the <code>read_iops_sec_max</code> is set.</dd>
          <dt><code>write_iops_sec_max</code></dt>
          <dd>The optional <code>write_iops_sec_max_length</code>
            element is the maximum duration in seconds for the
            <code>write_iops_sec_max</code> burst period. Only valid
            when the <code>write_iops_sec_max</code> is set.
          <p>
            <span class="since">Throughput length since 2.4.0 and QEMU 2.6</span>
          </p>
          </dd>
L
Lei Li 已提交
2797
        </dl>
2798
      </dd>
D
Daniel P. Berrange 已提交
2799
      <dt><code>driver</code></dt>
M
Matthias Dahl 已提交
2800 2801 2802
      <dd>
        The optional driver element allows specifying further details
        related to the hypervisor driver used to provide the disk.
2803
        <span class="since">Since 0.1.8</span>
M
Matthias Dahl 已提交
2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817
        <ul>
          <li>
            If the hypervisor supports multiple backend drivers, then
            the <code>name</code> attribute selects the primary
            backend driver name, while the optional <code>type</code>
            attribute provides the sub-type.  For example, xen
            supports a name of "tap", "tap2", "phy", or "file", with a
            type of "aio", while qemu only supports a name of "qemu",
            but multiple types including "raw", "bochs", "qcow2", and
            "qed".
          </li>
          <li>
            The optional <code>cache</code> attribute controls the
            cache mechanism, possible values are "default", "none",
2818 2819 2820 2821 2822 2823 2824 2825 2826
            "writethrough", "writeback", "directsync" (like
            "writethrough", but it bypasses the host page cache) and
            "unsafe" (host may cache all disk io, and sync requests from
            guest are ignored).
            <span class="since">
              Since 0.6.0,
              "directsync" since 0.9.5,
              "unsafe" since 0.9.7
            </span>
M
Matthias Dahl 已提交
2827 2828 2829
          </li>
          <li>
            The optional <code>error_policy</code> attribute controls
2830 2831 2832
            how the hypervisor will behave on a disk read or write
            error, possible values are "stop", "report", "ignore", and
            "enospace".<span class="since">Since 0.8.0, "report" since
2833 2834
            0.9.7</span> The default is left to the discretion of the
            hypervisor. There is also an
2835 2836
            optional <code>rerror_policy</code> that controls behavior
            for read errors only. <span class="since">Since
E
Eric Blake 已提交
2837
            0.9.7</span>. If no rerror_policy is given, error_policy
2838 2839 2840 2841 2842
            is used for both read and write errors. If rerror_policy
            is given, it overrides the <code>error_policy</code> for
            read errors. Also note that "enospace" is not a valid
            policy for read errors, so if <code>error_policy</code> is
            set to "enospace" and no <code>rerror_policy</code> is
2843
            given, the read error policy will be left at its default.
M
Matthias Dahl 已提交
2844 2845 2846 2847
          </li>
          <li>
            The optional <code>io</code> attribute controls specific
            policies on I/O; qemu guests support "threads" and
2848
            "native". <span class="since">Since 0.8.8</span>
M
Matthias Dahl 已提交
2849
          </li>
2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863
          <li>
            The optional <code>ioeventfd</code> attribute allows users to
            set <a href='https://patchwork.kernel.org/patch/43390/'>
            domain I/O asynchronous handling</a> for disk device.
            The default is left to the discretion of the hypervisor.
            Accepted values are "on" and "off". Enabling this allows
            qemu to execute VM while a separate thread handles I/O.
            Typically guests experiencing high system CPU utilization
            during I/O will benefit from this. On the other hand,
            on overloaded host it could increase guest I/O latency.
            <span class="since">Since 0.9.3 (QEMU and KVM only)</span>
            <b>In general you should leave this option alone, unless you
            are very certain you know what you are doing.</b>
          </li>
2864 2865 2866 2867
          <li>
            The optional <code>event_idx</code> attribute controls
            some aspects of device event processing. The value can be
            either 'on' or 'off' - if it is on, it will reduce the
2868
            number of interrupts and exits for the guest. The default
2869 2870 2871 2872 2873 2874 2875 2876
            is determined by QEMU; usually if the feature is
            supported, default is on. In case there is a situation
            where this behavior is suboptimal, this attribute provides
            a way to force the feature off.
            <span class="since">Since 0.9.5 (QEMU and KVM only)</span>
            <b>In general you should leave this option alone, unless you
            are very certain you know what you are doing.</b>
          </li>
O
Osier Yang 已提交
2877 2878
          <li>
            The optional <code>copy_on_read</code> attribute controls
2879
            whether to copy read backing file into the image file. The
O
Osier Yang 已提交
2880 2881 2882 2883 2884 2885
            value can be either "on" or "off".
            Copy-on-read avoids accessing the same backing file sectors
            repeatedly and is useful when the backing file is over a slow
            network. By default copy-on-read is off.
            <span class='since'>Since 0.9.10 (QEMU and KVM only)</span>
          </li>
O
Osier Yang 已提交
2886 2887 2888 2889
          <li>
            The optional <code>discard</code> attribute controls whether
            to discard (also known as "trim" or "unmap") requests are
            ignored or passed to the filesystem. The value can be either
O
Osier Yang 已提交
2890 2891
            "unmap" (allow the discard request to be passed) or "ignore"
            (ignore the discard request).
O
Osier Yang 已提交
2892 2893
            <span class='since'>Since 1.0.6 (QEMU and KVM only)</span>
          </li>
2894 2895 2896 2897 2898 2899 2900 2901 2902 2903
          <li>
            The optional <code>detect_zeroes</code> attribute controls whether
            to detect zero write requests.  The value can be "off", "on" or
            "unmap".  First two values turn the detection off and on,
            respectively.  The third value ("unmap") turns the detection on
            and additionally tries to discard such areas from the image based
            on the value of <code>discard</code> above (it will act as "on"
            if <code>discard</code> is set to "ignore").  NB enabling the
            detection is a compute intensive operation, but can save file
            space and/or time on slow media.
2904
            <span class='since'>Since 2.0.0</span>
2905
          </li>
2906 2907 2908 2909
          <li>
            The optional <code>iothread</code> attribute assigns the
            disk to an IOThread as defined by the range for the domain
            <a href="#elementsIOThreadsAllocation"><code>iothreads</code></a>
2910 2911 2912 2913 2914
            value. Multiple disks may be assigned to the same IOThread and
            are numbered from 1 to the domain iothreads value. Available
            for a disk device <code>target</code> configured to use "virtio"
            <code>bus</code> and "pci" or "ccw" <code>address</code> types.
            <span class='since'>Since 1.2.8 (QEMU 2.1)</span>
2915
          </li>
M
Matthias Dahl 已提交
2916
        </ul>
D
Daniel P. Berrange 已提交
2917
      </dd>
2918 2919 2920 2921 2922 2923
      <dt><code>backenddomain</code></dt>
      <dd>The optional <code>backenddomain</code> element allows specifying a
          backend domain (aka driver domain) hosting the disk.  Use the
          <code>name</code> attribute to specify the backend domain name.
          <span class="since">Since 1.2.13 (Xen only)</span>
      </dd>
2924 2925 2926 2927 2928 2929 2930 2931
      <dt><code>boot</code></dt>
      <dd>Specifies that the disk is bootable. The <code>order</code>
        attribute determines the order in which devices will be tried during
        boot sequence. The per-device <code>boot</code> elements cannot be
        used together with general boot elements in
        <a href="#elementsOSBIOS">BIOS bootloader</a> section.
        <span class="since">Since 0.8.8</span>
      </dd>
2932 2933 2934 2935 2936
      <dt><code>encryption</code></dt>
      <dd>If present, specifies how the volume is encrypted.  See
        the <a href="formatstorageencryption.html">Storage Encryption</a> page
        for more information.
      </dd>
2937 2938 2939
      <dt><code>readonly</code></dt>
      <dd>If present, this indicates the device cannot be modified by
        the guest.  For now, this is the default for disks with
2940
        attribute <code>device='cdrom'</code>.
2941
      </dd>
2942 2943 2944 2945 2946
      <dt><code>shareable</code></dt>
      <dd>If present, this indicates the device is expected to be shared
          between domains (assuming the hypervisor and OS support this),
          which means that caching should be deactivated for that device.
      </dd>
2947 2948 2949 2950 2951 2952 2953
      <dt><code>transient</code></dt>
      <dd>If present, this indicates that changes to the device
        contents should be reverted automatically when the guest
        exits.  With some hypervisors, marking a disk transient
        prevents the domain from participating in migration or
        snapshots. <span class="since">Since 0.9.5</span>
      </dd>
2954 2955
      <dt><code>serial</code></dt>
      <dd>If present, this specify serial number of virtual hard drive.
E
Eric Blake 已提交
2956 2957
          For example, it may look
          like <code>&lt;serial&gt;WD-WMAP9A966149&lt;/serial&gt;</code>.
2958 2959 2960
          Not supported for scsi-block devices, that is those using
          disk <code>type</code> 'block' using <code>device</code> 'lun'
          on <code>bus</code> 'scsi'.
2961 2962
          <span class="since">Since 0.7.1</span>
      </dd>
O
Osier Yang 已提交
2963 2964 2965
      <dt><code>wwn</code></dt>
      <dd>If present, this element specifies the WWN (World Wide Name)
        of a virtual hard disk or CD-ROM drive. It must be composed
2966 2967
        of 16 hexadecimal digits and must be unique (at least among
        disks of a single domain)
O
Osier Yang 已提交
2968 2969
        <span class='since'>Since 0.10.1</span>
      </dd>
2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981
      <dt><code>vendor</code></dt>
      <dd>If present, this element specifies the vendor of a virtual hard
        disk or CD-ROM device. It must not be longer than 8 printable
        characters.
        <span class='since'>Since 1.0.1</span>
      </dd>
      <dt><code>product</code></dt>
      <dd>If present, this element specifies the product of a virtual hard
        disk or CD-ROM device. It must not be longer than 16 printable
        characters.
        <span class='since'>Since 1.0.1</span>
      </dd>
E
Eric Blake 已提交
2982 2983 2984 2985 2986 2987 2988 2989 2990
      <dt><code>address</code></dt>
      <dd>If present, the <code>address</code> element ties the disk
        to a given slot of a controller (the
        actual <code>&lt;controller&gt;</code> device can often be
        inferred by libvirt, although it can
        be <a href="#elementsControllers">explicitly specified</a>).
        The <code>type</code> attribute is mandatory, and is typically
        "pci" or "drive".  For a "pci" controller, additional
        attributes for <code>bus</code>, <code>slot</code>,
2991 2992 2993 2994 2995
        and <code>function</code> must be present, as well as
        optional <code>domain</code> and <code>multifunction</code>.
        Multifunction defaults to 'off'; any other value requires
        QEMU 0.1.3 and <span class="since">libvirt 0.9.7</span>.  For a
        "drive" controller, additional attributes
2996 2997 2998
        <code>controller</code>, <code>bus</code>, <code>target</code>
        (<span class="since">libvirt 0.9.11</span>), and <code>unit</code>
        are available, each defaulting to 0.
2999 3000
      </dd>
      <dt><code>auth</code></dt>
3001 3002 3003 3004
      <dd>The <code>auth</code> element is supported for a disk
        <code>type</code> "network" that is using a <code>source</code>
        element with the <code>protocol</code> attributes "rbd" or "iscsi".
        If present, the <code>auth</code> element provides the
3005 3006 3007 3008 3009 3010 3011 3012
        authentication credentials needed to access the source.  It
        includes a mandatory attribute <code>username</code>, which
        identifies the username to use during authentication, as well
        as a sub-element <code>secret</code> with mandatory
        attribute <code>type</code>, to tie back to
        a <a href="formatsecret.html">libvirt secret object</a> that
        holds the actual password or other credentials (the domain XML
        intentionally does not expose the password, only the reference
3013 3014 3015 3016 3017
        to the object that does manage the password).
        Known secret types are "ceph" for Ceph RBD network sources and
        "iscsi" for CHAP authentication of iSCSI targets.
        Both will require either a <code>uuid</code> attribute
        with the UUID of the secret object or a <code>usage</code>
3018 3019
        attribute matching the key that was specified in the
        secret object.  <span class="since">libvirt 0.9.7</span>
E
Eric Blake 已提交
3020
      </dd>
J
J.B. Joret 已提交
3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039
      <dt><code>geometry</code></dt>
      <dd>The optional <code>geometry</code> element provides the
        ability to override geometry settings. This mostly useful for
        S390 DASD-disks or older DOS-disks.  <span class="since">0.10.0</span>
        <dl>
          <dt><code>cyls</code></dt>
          <dd>The <code>cyls</code> attribute is the
            number of cylinders. </dd>
          <dt><code>heads</code></dt>
          <dd>The <code>heads</code> attribute is the
            number of heads. </dd>
          <dt><code>secs</code></dt>
          <dd>The <code>secs</code> attribute is the
            number of sectors per track. </dd>
          <dt><code>trans</code></dt>
          <dd>The optional <code>trans</code> attribute is the
            BIOS-Translation-Modus (none, lba or auto)</dd>
        </dl>
      </dd>
V
Viktor Mihajlovski 已提交
3040 3041
      <dt><code>blockio</code></dt>
      <dd>If present, the <code>blockio</code> element allows
3042 3043 3044 3045 3046 3047 3048 3049
        to override any of the block device properties listed below.
        <span class="since">Since 0.10.2 (QEMU and KVM)</span>
        <dl>
          <dt><code>logical_block_size</code></dt>
          <dd>The logical block size the disk will report to the guest
            OS. For Linux this would be the value returned by the
            BLKSSZGET ioctl and describes the smallest units for disk
            I/O.
3050
          </dd>
3051 3052 3053 3054 3055
          <dt><code>physical_block_size</code></dt>
          <dd>The physical block size the disk will report to the guest
            OS. For Linux this would be the value returned by the
            BLKPBSZGET ioctl and describes the disk's hardware sector
            size which can be relevant for the alignment of disk data.
3056
          </dd>
3057 3058
        </dl>
      </dd>
D
Daniel P. Berrange 已提交
3059 3060
    </dl>

3061 3062 3063 3064 3065 3066 3067 3068
    <h4><a name="elementsFilesystems">Filesystems</a></h4>

    <p>
      A directory on the host that can be accessed directly from the guest.
      <span class="since">since 0.3.3, since 0.8.5 for QEMU/KVM</span>
    </p>

<pre>
3069 3070 3071 3072 3073 3074 3075 3076 3077 3078 3079 3080 3081 3082 3083 3084 3085 3086 3087
...
&lt;devices&gt;
  &lt;filesystem type='template'&gt;
    &lt;source name='my-vm-template'/&gt;
    &lt;target dir='/'/&gt;
  &lt;/filesystem&gt;
  &lt;filesystem type='mount' accessmode='passthrough'&gt;
    &lt;driver type='path' wrpolicy='immediate'/&gt;
    &lt;source dir='/export/to/guest'/&gt;
    &lt;target dir='/import/from/host'/&gt;
    &lt;readonly/&gt;
  &lt;/filesystem&gt;
  &lt;filesystem type='file' accessmode='passthrough'&gt;
    &lt;driver name='loop' type='raw'/&gt;
    &lt;driver type='path' wrpolicy='immediate'/&gt;
    &lt;source file='/export/to/guest.img'/&gt;
    &lt;target dir='/import/from/host'/&gt;
    &lt;readonly/&gt;
  &lt;/filesystem&gt;
3088
  ...
3089 3090
&lt;/devices&gt;
...</pre>
3091 3092 3093 3094 3095 3096 3097 3098 3099

    <dl>
      <dt><code>filesystem</code></dt>
      <dd>

      The filesystem attribute <code>type</code> specifies the type of the
      <code>source</code>. The possible values are:

        <dl>
3100
        <dt><code>mount</code></dt>
3101 3102 3103 3104
        <dd>
        A host directory to mount in the guest. Used by LXC,
        OpenVZ <span class="since">(since 0.6.2)</span>
        and QEMU/KVM <span class="since">(since 0.8.5)</span>.
3105
        This is the default <code>type</code> if one is not specified.
3106 3107 3108 3109
        This mode also has an optional
        sub-element <code>driver</code>, with an
        attribute <code>type='path'</code>
        or <code>type='handle'</code> <span class="since">(since
3110 3111 3112 3113 3114 3115
        0.9.7)</span>. The driver block has an optional attribute
        <code>wrpolicy</code> that further controls interaction with
        the host page cache; omitting the attribute gives default behavior,
        while the value <code>immediate</code> means that a host writeback
        is immediately triggered for all pages touched during a guest file
        write operation <span class="since">(since 0.9.10)</span>.
3116
        </dd>
3117
        <dt><code>template</code></dt>
3118 3119 3120
        <dd>
        OpenVZ filesystem template. Only used by OpenVZ driver.
        </dd>
3121
        <dt><code>file</code></dt>
3122
        <dd>
3123 3124 3125
        A host file will be treated as an image and mounted in
        the guest. The filesystem format will be autodetected.
        Only used by LXC driver.
3126
        </dd>
3127
        <dt><code>block</code></dt>
3128
        <dd>
3129 3130 3131
        A host block device to mount in the guest. The filesystem
        format will be autodetected. Only used by LXC driver
        <span class="since">(since 0.9.5)</span>.
3132
        </dd>
3133
        <dt><code>ram</code></dt>
3134 3135 3136
        <dd>
          An in-memory filesystem, using memory from the host OS.
          The source element has a single attribute <code>usage</code>
3137 3138
          which gives the memory usage limit in KiB, unless units
          are specified by the <code>units</code> attribute. Only used
3139 3140
          by LXC driver.
          <span class="since"> (since 0.9.13)</span></dd>
3141
        <dt><code>bind</code></dt>
3142 3143 3144 3145
        <dd>
          A directory inside the guest will be bound to another
          directory inside the guest. Only used by LXC driver
          <span class="since"> (since 0.9.13)</span></dd>
3146 3147
        </dl>

3148
      The filesystem block has an optional attribute <code>accessmode</code>
3149 3150 3151 3152 3153 3154
      which specifies the security mode for accessing the source
      <span class="since">(since 0.8.5)</span>. Currently this only works
      with <code>type='mount'</code> for the QEMU/KVM driver. The possible
      values are:

        <dl>
3155
        <dt><code>passthrough</code></dt>
3156 3157
        <dd>
        The <code>source</code> is accessed with the permissions of the
3158
        user inside the guest. This is the default <code>accessmode</code> if
3159 3160 3161
        one is not specified.
        <a href="http://lists.gnu.org/archive/html/qemu-devel/2010-05/msg02673.html">More info</a>
        </dd>
3162
        <dt><code>mapped</code></dt>
3163 3164 3165 3166 3167
        <dd>
        The <code>source</code> is accessed with the permissions of the
        hypervisor (QEMU process).
        <a href="http://lists.gnu.org/archive/html/qemu-devel/2010-05/msg02673.html">More info</a>
        </dd>
3168
        <dt><code>squash</code></dt>
3169 3170 3171 3172 3173 3174 3175 3176 3177 3178 3179
        <dd>
        Similar to 'passthrough', the exception is that failure of
        privileged operations like 'chown' are ignored. This makes a
        passthrough-like mode usable for people who run the hypervisor
        as non-root.
        <a href="http://lists.gnu.org/archive/html/qemu-devel/2010-09/msg00121.html">More info</a>
        </dd>
        </dl>

      </dd>

3180 3181 3182 3183 3184 3185 3186 3187 3188 3189 3190
      <dt><code>driver</code></dt>
      <dd>
        The optional driver element allows specifying further details
        related to the hypervisor driver used to provide the filesystem.
        <span class="since">Since 1.0.6</span>
        <ul>
          <li>
            If the hypervisor supports multiple backend drivers, then
            the <code>type</code> attribute selects the primary
            backend driver name, while the <code>format</code>
            attribute provides the format type. For example, LXC
3191 3192
            supports a type of "loop", with a format of "raw" or
            "nbd" with any format. QEMU supports a type of "path"
3193
            or "handle", but no formats. Virtuozzo driver supports
D
Dmitry Guryanov 已提交
3194
            a type of "ploop" with a format of "ploop".
3195 3196 3197 3198
          </li>
        </ul>
      </dd>

3199 3200 3201 3202 3203
      <dt><code>source</code></dt>
      <dd>
        The resource on the host that is being accessed in the guest. The
        <code>name</code> attribute must be used with
        <code>type='template'</code>, and the <code>dir</code> attribute must
3204
        be used with <code>type='mount'</code>. The <code>usage</code> attribute
3205 3206
        is used with <code>type='ram'</code> to set the memory limit in KiB,
        unless units are specified by the <code>units</code> attribute.
3207 3208 3209 3210 3211 3212 3213 3214 3215 3216 3217 3218
      </dd>

      <dt><code>target</code></dt>
      <dd>
        Where the <code>source</code> can be accessed in the guest. For
        most drivers this is an automatic mount point, but for QEMU/KVM
        this is merely an arbitrary string tag that is exported to the
        guest as a hint for where to mount.
      </dd>

      <dt><code>readonly</code></dt>
      <dd>
3219
        Enables exporting filesystem as a readonly mount for guest, by
3220 3221
        default read-write access is given (currently only works for
        QEMU/KVM driver).
3222
      </dd>
3223 3224 3225 3226 3227 3228 3229 3230 3231 3232 3233 3234 3235 3236

      <dt><code>space_hard_limit</code></dt>
      <dd>
        Maximum space available to this guest's filesystem.
        <span class="since">Since 0.9.13</span>
      </dd>

      <dt><code>space_soft_limit</code></dt>
      <dd>
        Maximum space available to this guest's filesystem. The container is
        permitted to exceed its soft limits for a grace period of time. Afterwards the
        hard limit is enforced.
        <span class="since">Since 0.9.13</span>
      </dd>
3237 3238
    </dl>

3239 3240 3241 3242 3243 3244 3245 3246 3247 3248 3249 3250 3251 3252 3253 3254 3255 3256 3257
    <h4><a name="elementsAddress">Device Addresses</a></h4>

    <p>
      Many devices have an optional <code>&lt;address&gt;</code>
      sub-element to describe where the device is placed on the
      virtual bus presented to the guest.  If an address (or any
      optional attribute within an address) is omitted on
      input, libvirt will generate an appropriate address; but an
      explicit address is required if more control over layout is
      required.  See below for device examples including an address
      element.
    </p>

    <p>
      Every address has a mandatory attribute <code>type</code> that
      describes which bus the device is on.  The choice of which
      address to use for a given device is constrained in part by the
      device and the architecture of the guest.  For example,
      a <code>&lt;disk&gt;</code> device
3258
      uses <code>type='drive'</code>, while
3259 3260 3261 3262 3263 3264 3265 3266
      a <code>&lt;console&gt;</code> device would
      use <code>type='pci'</code> on i686 or x86_64 guests,
      or <code>type='spapr-vio'</code> on PowerPC64 pseries guests.
      Each address type has further optional attributes that control
      where on the bus the device will be placed:
    </p>

    <dl>
3267
      <dt><code>pci</code></dt>
3268 3269 3270 3271 3272 3273 3274 3275 3276 3277 3278 3279
      <dd>PCI addresses have the following additional
        attributes: <code>domain</code> (a 2-byte hex integer, not
        currently used by qemu), <code>bus</code> (a hex value between
        0 and 0xff, inclusive), <code>slot</code> (a hex value between
        0x0 and 0x1f, inclusive), and <code>function</code> (a value
        between 0 and 7, inclusive).  Also available is
        the <code>multifunction</code> attribute, which controls
        turning on the multifunction bit for a particular
        slot/function in the PCI control register
        (<span class="since">since 0.9.7, requires QEMU
        0.13</span>). <code>multifunction</code> defaults to 'off',
        but should be set to 'on' for function 0 of a slot that will
3280 3281 3282 3283 3284 3285 3286
        have multiple functions used.<br/>
        <span class="since">Since 1.3.5</span>, some hypervisor
        drivers may accept an <code>&lt;address type='pci'/&gt;</code>
        element with no other attributes as an explicit request to
        assign a PCI address for the device rather than some other
        type of address that may also be appropriate for that same
        device (e.g. virtio-mmio).
3287
      </dd>
3288
      <dt><code>drive</code></dt>
3289 3290 3291
      <dd>Drive addresses have the following additional
        attributes: <code>controller</code> (a 2-digit controller
        number), <code>bus</code> (a 2-digit bus number),
3292
        <code>target</code> (a 2-digit target number),
3293 3294
        and <code>unit</code> (a 2-digit unit number on the bus).
      </dd>
3295
      <dt><code>virtio-serial</code></dt>
3296 3297 3298 3299 3300
      <dd>Each virtio-serial address has the following additional
        attributes: <code>controller</code> (a 2-digit controller
        number), <code>bus</code> (a 2-digit bus number),
        and <code>slot</code> (a 2-digit slot within the bus).
      </dd>
3301
      <dt><code>ccid</code></dt>
3302 3303 3304 3305
      <dd>A CCID address, for smart-cards, has the following
        additional attributes: <code>bus</code> (a 2-digit bus
        number), and <code>slot</code> attribute (a 2-digit slot
        within the bus).  <span class="since">Since 0.8.8.</span>
3306
      </dd>
3307
      <dt><code>usb</code></dt>
3308 3309 3310 3311 3312
      <dd>USB addresses have the following additional
        attributes: <code>bus</code> (a hex value between 0 and 0xfff,
        inclusive), and <code>port</code> (a dotted notation of up to
        four octets, such as 1.2 or 2.1.3.1).
      </dd>
3313
      <dt><code>spapr-vio</code></dt>
3314 3315 3316 3317 3318 3319 3320 3321
      <dd>On PowerPC pseries guests, devices can be assigned to the
        SPAPR-VIO bus.  It has a flat 64-bit address space; by
        convention, devices are generally assigned at a non-zero
        multiple of 0x1000, but other addresses are valid and
        permitted by libvirt.  Each address has the following
        additional attribute: <code>reg</code> (the hex value address
        of the starting register).  <span class="since">Since
        0.9.9.</span>
3322
      </dd>
3323
      <dt><code>ccw</code></dt>
B
Boris Fiuczynski 已提交
3324
      <dd>S390 guests with a <code>machine</code> value of
3325 3326 3327 3328 3329 3330 3331
        s390-ccw-virtio use the native CCW bus for I/O devices.
        CCW bus addresses have the following additional attributes:
        <code>cssid</code> (a hex value between 0 and 0xfe, inclusive),
        <code>ssid</code> (a value between 0 and 3, inclusive) and
        <code>devno</code> (a hex value between 0 and 0xffff, inclusive).
        Partially specified bus addresses are not allowed.
        If omitted, libvirt will assign a free bus address with
3332 3333
        cssid=0xfe and ssid=0. Virtio-ccw devices must have their cssid
        set to 0xfe.
3334
        <span class="since">Since 1.0.4</span>
3335
      </dd>
3336 3337 3338 3339 3340
      <dt><code>virtio-mmio</code></dt>
      <dd>This places the device on the virtio-mmio transport, which is
        currently only available for some <code>armv7l</code> and
        <code>aarch64</code> virtual machines. virtio-mmio addresses
        do not have any additional attributes.
3341 3342 3343 3344 3345 3346 3347
        <span class="since">Since 1.1.3</span><br/>
        If the guest architecture is <code>aarch64</code> and the machine
        type is <code>virt</code>, libvirt will automatically assign PCI
        addresses to devices; however, the presence of a single device
        with virtio-mmio address in the guest configuration will cause
        libvirt to assign virtio-mmio addresses to all further devices.
        <span class="since">Since 3.0.0</span>
3348
      </dd>
3349
      <dt><code>isa</code></dt>
H
Hu Tao 已提交
3350 3351 3352 3353
      <dd>ISA addresses have the following additional
        attributes: <code>iobase</code> and <code>irq</code>.
        <span class="since">Since 1.2.1</span>
      </dd>
3354 3355
    </dl>

E
Eric Blake 已提交
3356 3357 3358
    <h4><a name="elementsControllers">Controllers</a></h4>

    <p>
3359
      Depending on the guest architecture, some device buses can
3360 3361
      appear more than once, with a group of virtual devices tied to a
      virtual controller.  Normally, libvirt can automatically infer such
E
Eric Blake 已提交
3362 3363 3364 3365 3366
      controllers without requiring explicit XML markup, but sometimes
      it is necessary to provide an explicit controller element.
    </p>

<pre>
3367 3368 3369 3370 3371 3372 3373 3374 3375 3376 3377
...
&lt;devices&gt;
  &lt;controller type='ide' index='0'/&gt;
  &lt;controller type='virtio-serial' index='0' ports='16' vectors='4'/&gt;
  &lt;controller type='virtio-serial' index='1'&gt;
    &lt;address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/&gt;
  &lt;/controller&gt;
  &lt;controller type='scsi' index='0' model='virtio-scsi'&gt;
    &lt;driver iothread='4'/&gt;
    &lt;address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/&gt;
  &lt;/controller&gt;
E
Eric Blake 已提交
3378
  ...
3379 3380
&lt;/devices&gt;
...</pre>
E
Eric Blake 已提交
3381 3382 3383

    <p>
      Each controller has a mandatory attribute <code>type</code>,
3384 3385
      which must be one of 'ide', 'fdc', 'scsi', 'sata', 'usb',
      'ccid', 'virtio-serial' or 'pci', and a mandatory
3386 3387
      attribute <code>index</code> which is the decimal integer
      describing in which order the bus controller is encountered (for
3388
      use in <code>controller</code> attributes of
3389 3390 3391 3392 3393
      <code>&lt;address&gt;</code> elements).
      <span class="since">Since 1.3.5</span> the index is optional; if
      not specified, it will be auto-assigned to be the lowest unused
      index for the given controller type. Some controller types have
      additional attributes that control specific features, such as:
3394 3395 3396 3397 3398 3399 3400 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410
    </p>

      <dl>
        <dt><code>virtio-serial</code></dt>
        <dd>The <code>virtio-serial</code> controller has two additional
        optional attributes <code>ports</code> and <code>vectors</code>,
        which control how many devices can be connected through the
        controller.</dd>
        <dt><code>scsi</code></dt>
        <dd>A <code>scsi</code> controller has an optional attribute
        <code>model</code>, which is one of 'auto', 'buslogic', 'ibmvscsi',
        'lsilogic', 'lsisas1068', 'lsisas1078', 'virtio-scsi' or
        'vmpvscsi'.</dd>
        <dt><code>usb</code></dt>
        <dd>A <code>usb</code> controller has an optional attribute
        <code>model</code>, which is one of "piix3-uhci", "piix4-uhci",
        "ehci", "ich9-ehci1", "ich9-uhci1", "ich9-uhci2", "ich9-uhci3",
3411 3412 3413
        "vt82c686b-uhci", "pci-ohci", "nec-xhci", "qusb1" (xen pvusb
        with qemu backend, version 1.1) or "qusb2" (xen pvusb with qemu
        backend, version 2.0). Additionally,
3414 3415 3416 3417 3418 3419 3420 3421 3422 3423 3424 3425
         <span class="since">since 0.10.0</span>, if the USB bus needs to
         be explicitly disabled for the guest, <code>model='none'</code>
         may be used.  <span class="since">Since 1.0.5</span>, no default
         USB controller will be built on s390.
         <span class="since">Since 1.3.5</span>, USB controllers accept a
         <code>ports</code> attribute to configure how many devices can be
         connected to the controller.</dd>
      </dl>

    <p>
      Note: The PowerPC64 "spapr-vio" addresses do not have an
      associated controller.
E
Eric Blake 已提交
3426 3427 3428 3429 3430 3431
    </p>

    <p>
      For controllers that are themselves devices on a PCI or USB bus,
      an optional sub-element <code>&lt;address&gt;</code> can specify
      the exact relationship of the controller to its master bus, with
3432
      semantics <a href="#elementsAddress">given above</a>.
E
Eric Blake 已提交
3433 3434
    </p>

3435 3436
    <p>
      An optional sub-element <code>driver</code> can specify the driver
3437
      specific options:
3438
    </p>
3439 3440 3441 3442 3443 3444 3445 3446 3447 3448 3449 3450 3451 3452 3453 3454 3455 3456 3457 3458 3459 3460 3461
    <dl>
      <dt><code>queues</code></dt>
      <dd>
        The optional <code>queues</code> attribute specifies the number of
        queues for the controller. For best performance, it's recommended to
        specify a value matching the number of vCPUs.
        <span class="since">Since 1.0.5 (QEMU and KVM only)</span>
      </dd>
      <dt><code>cmd_per_lun</code></dt>
      <dd>
        The optional <code>cmd_per_lun</code> attribute specifies the maximum
        number of commands that can be queued on devices controlled by the
        host.
        <span class="since">Since 1.2.7 (QEMU and KVM only)</span>
      </dd>
      <dt><code>max_sectors</code></dt>
      <dd>
        The optional <code>max_sectors</code> attribute specifies the maximum
        amount of data in bytes that will be transferred to or from the device
        in a single command. The transfer length is measured in sectors, where
        a sector is 512 bytes.
        <span class="since">Since 1.2.7 (QEMU and KVM only)</span>
      </dd>
3462 3463 3464 3465 3466 3467 3468 3469
      <dt><code>ioeventfd</code></dt>
      <dd>
        The optional <code>ioeventfd</code> attribute specifies
        whether the controller should use
        <a href='https://patchwork.kernel.org/patch/43390/'>
        I/O asynchronous handling</a> or not.  Accepted values are
        "on" and "off". <span class="since">Since 1.2.18</span>
      </dd>
3470 3471 3472 3473 3474 3475 3476 3477 3478 3479 3480 3481 3482 3483 3484 3485 3486
      <dt><code>iothread</code></dt>
      <dd>
        Supported for controller type <code>scsi</code> using model
        <code>virtio-scsi</code> for <code>address</code> types
        <code>pci</code> and <code>ccw</code>
        <span class="since">since 1.3.5 (QEMU 2.4)</span>.

        The optional <code>iothread</code> attribute assigns the controller
        to an IOThread as defined by the range for the domain
        <a href="#elementsIOThreadsAllocation"><code>iothreads</code></a>
        value. Each SCSI <code>disk</code> assigned to use the specified
        <code>controller</code> will utilize the same IOThread. If a specific
        IOThread is desired for a specific SCSI <code>disk</code>, then
        multiple controllers must be defined each having a specific
        <code>iothread</code> value. The <code>iothread</code> value
        must be within the range 1 to the domain iothreads value.
      </dd>
3487
    </dl>
3488 3489 3490 3491 3492 3493
    <p>
      USB companion controllers have an optional
      sub-element <code>&lt;master&gt;</code> to specify the exact
      relationship of the companion to its master controller.
      A companion controller is on the same bus as its master, so
      the companion <code>index</code> value should be equal.
3494 3495 3496 3497 3498
      Not all controller models can be used as companion controllers
      and libvirt might provide some sensible defaults (settings
      of <code>master startport</code> and <code>function</code> of an
      address) for some particular models.
      Preferred companion controllers are <code>ich-uhci[123]</code>.
3499 3500 3501
    </p>

<pre>
3502 3503 3504 3505 3506 3507 3508 3509 3510
...
&lt;devices&gt;
  &lt;controller type='usb' index='0' model='ich9-ehci1'&gt;
    &lt;address type='pci' domain='0' bus='0' slot='4' function='7'/&gt;
  &lt;/controller&gt;
  &lt;controller type='usb' index='0' model='ich9-uhci1'&gt;
    &lt;master startport='0'/&gt;
    &lt;address type='pci' domain='0' bus='0' slot='4' function='0' multifunction='on'/&gt;
  &lt;/controller&gt;
3511
  ...
3512 3513
&lt;/devices&gt;
...</pre>
J
Ján Tomko 已提交
3514 3515 3516

    <p>
      PCI controllers have an optional <code>model</code> attribute with
3517
      possible values <code>pci-root</code>, <code>pcie-root</code>,
3518
      <code>pcie-root-port</code>, <code>pci-bridge</code>,
3519
      <code>dmi-to-pci-bridge</code>, <code>pcie-switch-upstream-port</code>,
3520 3521 3522 3523 3524 3525 3526 3527 3528 3529 3530 3531
      <code>pcie-switch-downstream-port</code>, <code>pci-expander-bus</code>,
      or <code>pcie-expander-bus</code>.  (pci-root and
      pci-bridge <span class="since">since 1.0.5</span>, pcie-root and
      dmi-to-pci-bridge <span class="since">since 1.1.2</span>,
      pcie-root-port, pcie-switch-upstream-port,
      pcie-switch-downstream-port <span class="since">since
      1.2.19</span>, and pci-expander-bus and
      pcie-expander-bus <span class="since">since 1.3.4</span>) The
      root controllers (<code>pci-root</code>
      and <code>pcie-root</code>) have an
      optional <code>pcihole64</code> element specifying how big (in
      kilobytes, or in the unit specified by <code>pcihole64</code>'s
3532 3533 3534 3535 3536
      <code>unit</code> attribute) the 64-bit PCI hole should be. Some guests (like
      Windows XP or Windows Server 2003) might crash when QEMU and Seabios
      are recent enough to support 64-bit PCI holes, unless this is disabled
      (set to 0). <span class="since">Since 1.1.2 (QEMU only)</span>
    </p>
3537 3538 3539 3540 3541 3542 3543 3544 3545 3546 3547 3548 3549
    <p>
      PCI controllers also have an optional
      subelement <code>&lt;model&gt;</code> with an attribute
      <code>name</code>. The name attribute holds the name of the
      specific device that qemu is emulating (e.g. "i82801b11-bridge")
      rather than simply the class of device ("dmi-to-pci-bridge",
      "pci-bridge"), which is set in the controller element's
      model <b>attribute</b>.  In almost all cases, you should not
      manually add a <code>&lt;model&gt;</code> subelement to a
      controller, nor should you modify one that is automatically
      generated by libvirt. <span class="since">Since 1.2.19 (QEMU
      only).</span>
    </p>
3550 3551
    <p>
      PCI controllers also have an optional
3552 3553 3554
      subelement <code>&lt;target&gt;</code> with the attributes and
      subelements listed below. These are configurable items that 1)
      are visible to the guest OS so must be preserved for guest ABI
3555 3556 3557 3558 3559 3560 3561 3562 3563 3564 3565 3566 3567 3568 3569 3570
      compatibility, and 2) are usually left to default values or
      derived automatically by libvirt. In almost all cases, you
      should not manually add a <code>&lt;target&gt;</code> subelement
      to a controller, nor should you modify the values in the those
      that are automatically generated by
      libvirt. <span class="since">Since 1.2.19 (QEMU only).</span>
    </p>
    <dl>
      <dt><code>chassisNr</code></dt>
      <dd>
        PCI controllers that have attribute model="pci-bridge", can
        also have a <code>chassisNr</code> attribute in
        the <code>&lt;target&gt;</code> subelement, which is used to
        control QEMU's "chassis_nr" option for the pci-bridge device
        (normally libvirt automatically sets this to the same value as
        the index attribute of the pci controller). If set, chassisNr
3571
        must be between 1 and 255.
3572
      </dd>
3573 3574
      <dt><code>chassis</code></dt>
      <dd>
3575 3576
        pcie-root-port and pcie-switch-downstream-port controllers can
        also have a <code>chassis</code> attribute in
3577 3578 3579 3580 3581 3582 3583
        the <code>&lt;target&gt;</code> subelement, which is used to
        set the controller's "chassis" configuration value, which is
        visible to the virtual machine. If set, chassis must be
        between 0 and 255.
      </dd>
      <dt><code>port</code></dt>
      <dd>
3584 3585 3586
        pcie-root-port and pcie-switch-downstream-port controllers can
        also have a <code>port</code> attribute in
        the <code>&lt;target&gt;</code> subelement, which
3587 3588 3589 3590
        is used to set the controller's "port" configuration value,
        which is visible to the virtual machine. If set, port must be
        between 0 and 255.
      </dd>
3591 3592
      <dt><code>busNr</code></dt>
      <dd>
3593
        pci-expander-bus and pcie-expander-bus controllers can have an
3594 3595 3596 3597 3598 3599 3600 3601 3602 3603 3604 3605 3606 3607
        optional <code>busNr</code> attribute (1-254). This will be
        the bus number of the new bus; All bus numbers between that
        specified and 255 will be available only for assignment to
        PCI/PCIe controllers plugged into the hierarchy starting with
        this expander bus, and bus numbers less than the specified
        value will be available to the next lower expander-bus (or the
        root-bus if there are no lower expander buses). If you do not
        specify a busNumber, libvirt will find the lowest existing
        busNumber in all other expander buses (or use 256 if there are
        no others) and auto-assign the busNr of that found bus - 2,
        which provides one bus number for the pci-expander-bus and one
        for the pci-bridge that is automatically attached to it (if
        you plan on adding more pci-bridges to the hierarchy of the
        bus, you should manually set busNr to a lower value).
3608 3609 3610 3611 3612 3613 3614
        <p>
          A similar algorithm is used for automatically determining
          the busNr attribute for pcie-expander-bus, but since the
          pcie-expander-bus doesn't have any built-in pci-bridge, the
          2nd bus-number is just being reserved for the pcie-root-port
          that must necessarily be connected to the bus in order to
          actually plug in an endpoint device. If you intend to plug
3615 3616 3617 3618 3619 3620 3621 3622 3623 3624 3625
          multiple devices into a pcie-expander-bus, you must connect
          a pcie-switch-upstream-port to the pcie-root-port that is
          plugged into the pcie-expander-bus, and multiple
          pcie-switch-downstream-ports to the
          pcie-switch-upstream-port, and of course for this to work
          properly, you will need to decrease the pcie-expander-bus'
          busNr accordingly so that there are enough unused bus
          numbers above it to accomodate giving out one bus number for
          the upstream-port and one for each downstream-port (in
          addition to the pcie-root-port and the pcie-expander-bus
          itself).
3626
        </p>
3627
      </dd>
3628
      <dt><code>node</code></dt>
3629 3630 3631 3632 3633 3634 3635 3636 3637 3638
      <dd>
        pci-expander-bus controllers can have an
        optional <code>&lt;node&gt;</code> subelement within
        the <code>&lt;target&gt;</code> subelement, which is used to
        set the NUMA node reported to the guest OS for that bus - the
        guest OS will then know that all devices on that bus are a
        part of the specified NUMA node (it is up to the user of the
        libvirt API to attach host devices to the correct
        pci-expander-bus when assigning them to the domain).
      </dd>
3639
    </dl>
3640
    <p>
L
Laine Stump 已提交
3641
      For machine types which provide an implicit PCI bus, the pci-root
J
Ján Tomko 已提交
3642
      controller with index=0 is auto-added and required to use PCI devices.
L
Laine Stump 已提交
3643
      pci-root has no address.
3644 3645 3646
      PCI bridges are auto-added if there are too many devices to fit on
      the one bus provided by pci-root, or a PCI bus number greater than zero
      was specified.
J
Ján Tomko 已提交
3647 3648 3649 3650 3651 3652
      PCI bridges can also be specified manually, but their addresses should
      only refer to PCI buses provided by already specified PCI controllers.
      Leaving gaps in the PCI controller indexes might lead to an invalid
      configuration.
    </p>
<pre>
3653 3654 3655 3656 3657 3658 3659 3660
...
&lt;devices&gt;
  &lt;controller type='pci' index='0' model='pci-root'/&gt;
  &lt;controller type='pci' index='1' model='pci-bridge'&gt;
    &lt;address type='pci' domain='0' bus='0' slot='5' function='0' multifunction='off'/&gt;
  &lt;/controller&gt;
&lt;/devices&gt;
...</pre>
L
Laine Stump 已提交
3661 3662 3663 3664 3665 3666

    <p>
      For machine types which provide an implicit PCI Express (PCIe)
      bus (for example, the machine types based on the Q35 chipset),
      the pcie-root controller with index=0 is auto-added to the
      domain's configuration. pcie-root has also no address, provides
3667 3668 3669 3670 3671 3672
      31 slots (numbered 1-31) that can be used to attach PCIe or PCI
      devices (although libvirt will never auto-assign a PCI device to
      a PCIe slot, it will allow manual specification of such an
      assignment). Devices connected to pcie-root cannot be
      hotplugged. In order to make standard PCI slots available on a
      system which has a pcie-root controller, a pci controller
3673
      with <code>model='dmi-to-pci-bridge'</code> is automatically
3674 3675 3676 3677
      added, usually at the defacto standard location of slot=0x1e. A
      dmi-to-pci-bridge controller plugs into a PCIe slot (as provided
      by pcie-root), and itself provides 31 standard PCI slots (which
      also do not support device hotplug). In order to have
3678 3679 3680
      hot-pluggable PCI slots in the guest system, a pci-bridge
      controller will also be automatically created and connected to
      one of the slots of the auto-created dmi-to-pci-bridge
3681
      controller; all guest PCI devices with addresses that are
3682 3683
      auto-determined by libvirt will be placed on this pci-bridge
      device.  (<span class="since">since 1.1.2</span>).
L
Laine Stump 已提交
3684
    </p>
3685 3686
    <p>
      Domains with an implicit pcie-root can also add controllers
3687 3688 3689 3690 3691 3692 3693 3694 3695 3696 3697 3698 3699 3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712
      with <code>model='pcie-root-port'</code>,
      <code>model='pcie-switch-upstream-port'</code>,
      and <code>model='pcie-switch-downstream-port'</code>. pcie-root-port
      is a simple type of bridge device that can connect only to one
      of the 31 slots on the pcie-root bus on its upstream side, and
      makes a single (PCIe, hotpluggable) port available on the
      downstream side (at slot='0'). pcie-root-port can be used to
      provide a single slot to later hotplug a PCIe device (but is not
      itself hotpluggable - it must be in the configuration when the
      domain is started).
      (<span class="since">since 1.2.19</span>)
    </p>
    <p>
      pcie-switch-upstream-port is a more flexible (but also more
      complex) device that can only plug into a pcie-root-port or
      pcie-switch-downstream-port on the upstream side (and only
      before the domain is started - it is not hot-pluggable), and
      provides 32 ports on the downstream side (slot='0' - slot='31')
      that accept only pcie-switch-downstream-port devices; each
      pcie-switch-downstream-port device can only plug into a
      pcie-switch-upstream-port on its upstream side (again, not
      hot-pluggable), and on its downstream side provides a single
      hotpluggable pcie port that can accept any standard pci or pcie
      device (or another pcie-switch-upstream-port), i.e. identical in
      function to a pcie-root-port.  (<span class="since">since
      1.2.19</span>)
3713
    </p>
L
Laine Stump 已提交
3714
<pre>
3715 3716 3717 3718 3719 3720 3721 3722 3723 3724 3725
...
&lt;devices&gt;
  &lt;controller type='pci' index='0' model='pcie-root'/&gt;
  &lt;controller type='pci' index='1' model='dmi-to-pci-bridge'&gt;
    &lt;address type='pci' domain='0' bus='0' slot='0xe' function='0'/&gt;
  &lt;/controller&gt;
  &lt;controller type='pci' index='2' model='pci-bridge'&gt;
    &lt;address type='pci' domain='0' bus='1' slot='1' function='0'/&gt;
  &lt;/controller&gt;
&lt;/devices&gt;
...</pre>
3726

3727 3728 3729 3730 3731 3732 3733 3734 3735
    <h4><a name="elementsLease">Device leases</a></h4>

    <p>
      When using a lock manager, it may be desirable to record device leases
      against a VM. The lock manager will ensure the VM won't start unless
      the leases can be acquired.
    </p>

<pre>
3736 3737
...
&lt;devices&gt;
3738
  ...
3739 3740 3741 3742 3743 3744 3745 3746
  &lt;lease&gt;
    &lt;lockspace&gt;somearea&lt;/lockspace&gt;
    &lt;key&gt;somekey&lt;/key&gt;
    &lt;target path='/some/lease/path' offset='1024'/&gt;
  &lt;/lease&gt;
  ...
&lt;/devices&gt;
...</pre>
3747 3748

    <dl>
3749
      <dt><code>lockspace</code></dt>
3750 3751 3752 3753
      <dd>This is an arbitrary string, identifying the lockspace
        within which the key is held. Lock managers may impose
        extra restrictions on the format, or length of the lockspace
        name.</dd>
3754
      <dt><code>key</code></dt>
3755 3756 3757 3758
      <dd>This is an arbitrary string, uniquely identifying the
        lease to be acquired. Lock managers may impose extra
        restrictions on the format, or length of the key.
      </dd>
3759
      <dt><code>target</code></dt>
3760 3761 3762 3763 3764 3765
      <dd>This is the fully qualified path of the file associated
        with the lockspace. The offset specifies where the lease
        is stored within the file. If the lock manager does not
        require a offset, just pass 0.
      </dd>
    </dl>
E
Eric Blake 已提交
3766

3767 3768
    <h4><a name="elementsHostDev">Host device assignment</a></h4>

3769
    <h5><a name="elementsHostDevSubsys">USB / PCI / SCSI devices</a></h5>
3770 3771

    <p>
H
Han Cheng 已提交
3772
      USB, PCI and SCSI devices attached to the host can be passed through
3773
      to the guest using the <code>hostdev</code> element.
H
Han Cheng 已提交
3774 3775
      <span class="since">since after 0.4.4 for USB, 0.6.0 for PCI(KVM only)
        and 1.0.6 for SCSI(KVM only)</span>:
3776 3777
    </p>

3778
<pre>
3779 3780 3781 3782 3783 3784 3785 3786 3787 3788 3789
...
&lt;devices&gt;
  &lt;hostdev mode='subsystem' type='usb'&gt;
    &lt;source startupPolicy='optional'&gt;
      &lt;vendor id='0x1234'/&gt;
      &lt;product id='0xbeef'/&gt;
    &lt;/source&gt;
    &lt;boot order='2'/&gt;
  &lt;/hostdev&gt;
&lt;/devices&gt;
...</pre>
3790

3791
    <p>or:</p>
3792 3793

<pre>
3794 3795 3796 3797 3798 3799 3800 3801 3802 3803 3804
...
&lt;devices&gt;
  &lt;hostdev mode='subsystem' type='pci' managed='yes'&gt;
    &lt;source&gt;
      &lt;address domain='0x0000' bus='0x06' slot='0x02' function='0x0'/&gt;
    &lt;/source&gt;
    &lt;boot order='1'/&gt;
    &lt;rom bar='on' file='/etc/fake/boot.bin'/&gt;
  &lt;/hostdev&gt;
&lt;/devices&gt;
...</pre>
H
Han Cheng 已提交
3805 3806 3807 3808

    <p>or:</p>

<pre>
3809 3810 3811 3812 3813 3814 3815 3816 3817 3818 3819 3820
...
&lt;devices&gt;
  &lt;hostdev mode='subsystem' type='scsi' sgio='filtered' rawio='yes'&gt;
    &lt;source&gt;
      &lt;adapter name='scsi_host0'/&gt;
      &lt;address bus='0' target='0' unit='0'/&gt;
    &lt;/source&gt;
    &lt;readonly/&gt;
    &lt;address type='drive' controller='0' bus='0' target='0' unit='0'/&gt;
  &lt;/hostdev&gt;
&lt;/devices&gt;
...</pre>
3821

J
John Ferlan 已提交
3822 3823 3824 3825

    <p>or:</p>

<pre>
3826 3827 3828 3829 3830 3831 3832 3833 3834 3835 3836 3837 3838
...
&lt;devices&gt;
  &lt;hostdev mode='subsystem' type='scsi'&gt;
    &lt;source protocol='iscsi' name='iqn.2014-08.com.example:iscsi-nopool/1'&gt;
      &lt;host name='example.com' port='3260'/&gt;
      &lt;auth username='myuser'&gt;
        &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
      &lt;/auth&gt;
    &lt;/source&gt;
    &lt;address type='drive' controller='0' bus='0' target='0' unit='0'/&gt;
  &lt;/hostdev&gt;
&lt;/devices&gt;
...</pre>
J
John Ferlan 已提交
3839

3840 3841 3842 3843 3844 3845 3846 3847 3848 3849 3850
    <p>or:</p>

<pre>
  ...
  &lt;devices&gt;
    &lt;hostdev mode='subsystem' type='scsi_host'&gt;
      &lt;source protocol='vhost' wwpn='naa.50014057667280d8'/&gt;
    &lt;/hostdev&gt;
  &lt;/devices&gt;
  ...</pre>

3851 3852 3853
    <dl>
      <dt><code>hostdev</code></dt>
      <dd>The <code>hostdev</code> element is the main container for describing
J
John Ferlan 已提交
3854 3855 3856 3857
        host devices. For each device, the <code>mode</code> is always
        "subsystem" and the <code>type</code> is one of the following values
        with additional attributes noted.
        <dl>
3858
          <dt><code>usb</code></dt>
3859 3860 3861
          <dd>USB devices are detached from the host on guest startup
            and reattached after the guest exits or the device is
            hot-unplugged.
J
John Ferlan 已提交
3862
          </dd>
3863
          <dt><code>pci</code></dt>
J
John Ferlan 已提交
3864 3865 3866
          <dd>For PCI devices, when <code>managed</code> is "yes" it is
            detached from the host before being passed on to the guest
            and reattached to the host after the guest exits. If
3867 3868 3869 3870 3871 3872
            <code>managed</code> is omitted or "no", the user is
            responsible to call <code>virNodeDeviceDetachFlags</code>
            (or <code>virsh nodedev-detach</code> before starting the guest
            or hot-plugging the device and <code>virNodeDeviceReAttach</code>
            (or <code>virsh nodedev-reattach</code>) after hot-unplug or
            stopping the guest.
J
John Ferlan 已提交
3873
          </dd>
3874
          <dt><code>scsi</code></dt>
J
John Ferlan 已提交
3875
          <dd>For SCSI devices, user is responsible to make sure the device
3876 3877 3878 3879 3880 3881
            is not used by host. If supported by the hypervisor and OS, the
            optional <code>sgio</code> (<span class="since">since 1.0.6</span>)
            attribute indicates whether unprivileged SG_IO commands are
            filtered for the disk. Valid settings are "filtered" or
            "unfiltered", where the default is "filtered".
            The optional <code>rawio</code>
3882 3883 3884 3885 3886 3887
            (<span class="since">since 1.2.9</span>) attribute indicates
            whether the lun needs the rawio capability. Valid settings are
            "yes" or "no". See the rawio description within the
            <a href="#elementsDisks">disk</a> section.
            If a disk lun in the domain already has the rawio capability,
            then this setting not required.
J
John Ferlan 已提交
3888
          </dd>
3889 3890 3891 3892 3893 3894
          <dt><code>scsi_host</code></dt>
          <dd><span class="since">since 2.5.0</span>For SCSI devices, user
            is responsible to make sure the device is not used by host. This
            <code>type</code> passes all LUNs presented by a single HBA to
            the guest.
          </dd>
J
John Ferlan 已提交
3895
        </dl>
3896 3897 3898 3899 3900 3901
        <p>
          Note: The <code>managed</code> attribute is only used with PCI devices
          and is ignored by all the other device types, thus setting
          <code>managed</code> explicitly with other than PCI device has the same
          effect as omitting it.
        </p>
O
Osier Yang 已提交
3902
      </dd>
3903
      <dt><code>source</code></dt>
J
John Ferlan 已提交
3904 3905 3906
      <dd>The source element describes the device as seen from the host using
        the following mechanism to describe:
        <dl>
3907
          <dt><code>usb</code></dt>
J
John Ferlan 已提交
3908 3909 3910 3911 3912 3913 3914 3915 3916 3917 3918 3919 3920 3921 3922 3923 3924 3925 3926 3927 3928 3929 3930 3931 3932 3933 3934
          <dd>The USB device can either be addressed by vendor / product id
            using the <code>vendor</code> and <code>product</code> elements
            or by the device's address on the host using the
            <code>address</code> element.
            <p>
            <span class="since">Since 1.0.0</span>, the <code>source</code>
            element of USB devices may contain <code>startupPolicy</code>
            attribute which can be used to define policy what to do if the
            specified host USB device is not found. The attribute accepts
            the following values:
            </p>
            <table class="top_table">
              <tr>
                <td> mandatory </td>
                <td> fail if missing for any reason (the default) </td>
              </tr>
              <tr>
                <td> requisite </td>
                <td> fail if missing on boot up,
                     drop if missing on migrate/restore/revert </td>
              </tr>
              <tr>
                <td> optional </td>
                <td> drop if missing at any start attempt </td>
              </tr>
            </table>
          </dd>
3935
          <dt><code>pci</code></dt>
J
John Ferlan 已提交
3936 3937
          <dd>PCI devices can only be described by their <code>address</code>.
          </dd>
3938
          <dt><code>scsi</code></dt>
J
John Ferlan 已提交
3939
          <dd>SCSI devices are described by both the <code>adapter</code>
3940 3941 3942 3943 3944 3945 3946 3947
            and <code>address</code> elements. The <code>address</code>
            element includes a <code>bus</code> attribute (a 2-digit bus
            number), a <code>target</code> attribute (a 10-digit target
            number), and a <code>unit</code> attribute (a 20-digit unit
            number on the bus). Not all hypervisors support larger
            <code>target</code> and <code>unit</code> values. It is up
            to each hypervisor to determine the maximum value supported
            for the adapter.
J
John Ferlan 已提交
3948 3949 3950 3951 3952 3953 3954 3955 3956 3957
            <p>
            <span class="since">Since 1.2.8</span>, the <code>source</code>
            element of a SCSI device may contain the <code>protocol</code>
            attribute. When the attribute is set to "iscsi", the host
            device XML follows the network <a href="#elementsDisks">disk</a>
            device using the same <code>name</code> attribute and optionally
            using the <code>auth</code> element to provide the authentication
            credentials to the iSCSI server.
            </p>
          </dd>
3958 3959 3960 3961 3962 3963 3964
          <dt><code>scsi_host</code></dt>
          <dd><span class="since">Since 2.5.0</span>, multiple LUNs behind a
            single SCSI HBA are described by a <code>protocol</code>
            attribute set to "vhost" and a <code>wwpn</code> attribute that
            is the vhost_scsi wwpn (16 hexadecimal digits with a prefix of
            "naa.") established in the host configfs.
          </dd>
J
John Ferlan 已提交
3965
        </dl>
3966
      </dd>
3967 3968 3969 3970 3971
      <dt><code>vendor</code>, <code>product</code></dt>
      <dd>The <code>vendor</code> and <code>product</code> elements each have an
      <code>id</code> attribute that specifies the USB vendor and product id.
      The ids can be given in decimal, hexadecimal (starting with 0x) or
      octal (starting with 0) form.</dd>
3972 3973 3974 3975 3976 3977
      <dt><code>boot</code></dt>
      <dd>Specifies that the device is bootable. The <code>order</code>
      attribute determines the order in which devices will be tried during
      boot sequence. The per-device <code>boot</code> elements cannot be
      used together with general boot elements in
      <a href="#elementsOSBIOS">BIOS bootloader</a> section.
3978 3979
      <span class="since">Since 0.8.8</span> for PCI devices,
      <span class="since">Since 1.0.1</span> for USB devices.
3980
      </dd>
3981 3982
      <dt><code>rom</code></dt>
      <dd>The <code>rom</code> element is used to change how a PCI
3983
        device's ROM is presented to the guest. The optional <code>bar</code>
3984 3985 3986 3987 3988 3989 3990
        attribute can be set to "on" or "off", and determines whether
        or not the device's ROM will be visible in the guest's memory
        map. (In PCI documentation, the "rombar" setting controls the
        presence of the Base Address Register for the ROM). If no rom
        bar is specified, the qemu default will be used (older
        versions of qemu used a default of "off", while newer qemus
        have a default of "on"). <span class="since">Since
3991
        0.9.7 (QEMU and KVM only)</span>. The optional
3992
        <code>file</code> attribute contains an absolute path to a binary file
3993 3994 3995 3996 3997
        to be presented to the guest as the device's ROM BIOS. This
        can be useful, for example, to provide a PXE boot ROM for a
        virtual function of an sr-iov capable ethernet device (which
        has no boot ROMs for the VFs).
        <span class="since">Since 0.9.10 (QEMU and KVM only)</span>.
3998
      </dd>
3999
      <dt><code>address</code></dt>
4000 4001 4002 4003 4004
      <dd>The <code>address</code> element for USB devices has a
      <code>bus</code> and <code>device</code> attribute to specify the
      USB bus and device number the device appears at on the host.
      The values of these attributes can be given in decimal, hexadecimal
      (starting with 0x) or octal (starting with 0) form.
4005
      For PCI devices the element carries 4 attributes allowing to designate
4006
      the device as can be found with the <code>lspci</code> or
4007 4008
      with <code>virsh nodedev-list</code>. For SCSI devices a 'drive'
      address type must be used. <a href="#elementsAddress">See above</a> for
4009 4010 4011 4012 4013 4014 4015 4016
      more details on the address element.</dd>
      <dt><code>driver</code></dt>
      <dd>
        PCI devices can have an optional <code>driver</code>
        subelement that specifies which backend driver to use for PCI
        device assignment. Use the <code>name</code> attribute to
        select either "vfio" (for the new VFIO device assignment
        backend, which is compatible with UEFI SecureBoot) or "kvm"
4017
        (the legacy device assignment handled directly by the KVM
4018
        kernel module)<span class="since">Since 1.0.5 (QEMU and KVM
4019 4020 4021 4022 4023 4024 4025 4026
        only, requires kernel 3.6 or newer)</span>. When specified,
        device assignment will fail if the requested method of device
        assignment isn't available on the host. When not specified,
        the default is "vfio" on systems where the VFIO driver is
        available and loaded, and "kvm" on older systems, or those
        where the VFIO driver hasn't been
        loaded <span class="since">Since 1.1.3</span> (prior to that
        the default was always "kvm").
4027
      </dd>
O
Osier Yang 已提交
4028 4029 4030 4031
      <dt><code>readonly</code></dt>
      <dd>Indicates that the device is readonly, only supported by SCSI host
        device now. <span class="since">Since 1.0.6 (QEMU and KVM only)</span>
      </dd>
4032 4033 4034 4035 4036
      <dt><code>shareable</code></dt>
      <dd>If present, this indicates the device is expected to be shared
        between domains (assuming the hypervisor and OS support this).
        Only supported by SCSI host device.
        <span class="since">Since 1.0.6</span>
4037 4038 4039 4040 4041
        <p>
          Note: Although <code>shareable</code> was introduced
          <span class="since">in 1.0.6</span>, it did not work as
          as expected until <span class="since">1.2.2</span>.
        </p>
4042
      </dd>
4043 4044
    </dl>

4045

4046
    <h5><a name="elementsHostDevCaps">Block / character devices</a></h5>
4047 4048 4049 4050

    <p>
      Block / character devices from the host can be passed through
      to the guest using the <code>hostdev</code> element. This is
4051 4052
      only possible with container based virtualization. Devices are specified
      by a fully qualified path.
4053 4054 4055 4056 4057 4058 4059 4060 4061 4062 4063 4064 4065 4066 4067 4068 4069 4070 4071 4072
      <span class="since">since after 1.0.1 for LXC</span>:
    </p>

    <pre>
...
&lt;hostdev mode='capabilities' type='storage'&gt;
  &lt;source&gt;
    &lt;block&gt;/dev/sdf1&lt;/block&gt;
  &lt;/source&gt;
&lt;/hostdev&gt;
...
    </pre>

    <pre>
...
&lt;hostdev mode='capabilities' type='misc'&gt;
  &lt;source&gt;
    &lt;char&gt;/dev/input/event3&lt;/char&gt;
  &lt;/source&gt;
&lt;/hostdev&gt;
4073 4074 4075
...
    </pre>

O
Osier Yang 已提交
4076
    <pre>
4077 4078 4079 4080 4081 4082
...
&lt;hostdev mode='capabilities' type='net'&gt;
  &lt;source&gt;
    &lt;interface&gt;eth0&lt;/interface&gt;
  &lt;/source&gt;
&lt;/hostdev&gt;
4083 4084 4085 4086 4087 4088 4089
...
    </pre>

    <dl>
      <dt><code>hostdev</code></dt>
      <dd>The <code>hostdev</code> element is the main container for describing
        host devices. For block/character device passthrough <code>mode</code> is
4090 4091
        always "capabilities" and <code>type</code> is "storage" for a block
        device, "misc" for a character device and "net" for a host network
4092
        interface.
4093 4094 4095 4096 4097
      </dd>
      <dt><code>source</code></dt>
      <dd>The source element describes the device as seen from the host.
        For block devices, the path to the block device in the host
        OS is provided in the nested "block" element, while for character
4098 4099
        devices the "char" element is used. For network interfaces, the
        name of the interface is provided in the "interface" element.
4100 4101 4102
      </dd>
    </dl>

4103 4104 4105 4106 4107 4108 4109 4110 4111
    <h4><a name="elementsRedir">Redirected devices</a></h4>

    <p>
      USB device redirection through a character device is
      supported <span class="since">since after 0.9.5 (KVM
      only)</span>:
    </p>

<pre>
4112 4113 4114 4115 4116 4117 4118 4119 4120 4121 4122 4123
...
&lt;devices&gt;
  &lt;redirdev bus='usb' type='tcp'&gt;
    &lt;source mode='connect' host='localhost' service='4000'/&gt;
    &lt;boot order='1'/&gt;
  &lt;/redirdev&gt;
  &lt;redirfilter&gt;
    &lt;usbdev class='0x08' vendor='0x1234' product='0xbeef' version='2.56' allow='yes'/&gt;
    &lt;usbdev allow='no'/&gt;
  &lt;/redirfilter&gt;
&lt;/devices&gt;
...</pre>
4124 4125 4126 4127 4128 4129 4130 4131 4132 4133 4134 4135 4136 4137

    <dl>
      <dt><code>redirdev</code></dt>
      <dd>The <code>redirdev</code> element is the main container for
        describing redirected devices. <code>bus</code> must be "usb"
        for a USB device.

        An additional attribute <code>type</code> is required,
        matching one of the
        supported <a href="#elementsConsole">serial device</a> types,
        to describe the host side of the
        tunnel; <code>type='tcp'</code>
        or <code>type='spicevmc'</code> (which uses the usbredir
        channel of a <a href="#elementsGraphics">SPICE graphics
J
Ján Tomko 已提交
4138 4139
        device</a>) are typical. The redirdev element has an optional
        sub-element <code>&lt;address&gt;</code> which can tie the
4140 4141 4142 4143
        device to a particular controller. Further sub-elements,
        such as <code>&lt;source&gt;</code>, may be required according
        to the given type, although a <code>&lt;target&gt;</code> sub-element
        is not required (since the consumer of the character device is
4144 4145 4146 4147 4148 4149 4150 4151 4152 4153
        the hypervisor itself, rather than a device visible in the guest).
      </dd>
      <dt><code>boot</code></dt>

      <dd>Specifies that the device is bootable.
        The <code>order</code> attribute determines the order in which
        devices will be tried during boot sequence. The per-device
        <code>boot</code> elements cannot be used together with general
        boot elements in  <a href="#elementsOSBIOS">BIOS bootloader</a> section.
        (<span class="since">Since 1.0.1</span>)
4154 4155 4156 4157
      </dd>
      <dt><code>redirfilter</code></dt>
      <dd>The<code> redirfilter </code>element is used for creating the
        filter rule to filter out certain devices from redirection.
J
Ján Tomko 已提交
4158 4159
        It uses sub-element <code>&lt;usbdev&gt;</code> to define each filter rule.
        <code>class</code> attribute is the USB Class code, for example,
4160
        0x08 represents mass storage devices. The USB device can be addressed by
J
Ján Tomko 已提交
4161
        vendor / product id using the <code>vendor</code> and <code>product</code> attributes.
4162 4163
        <code>version</code> is the device revision from the bcdDevice field (not
        the version of the USB protocol).
4164
        These four attributes are optional and <code>-1</code> can be used to allow
J
Ján Tomko 已提交
4165
        any value for them. <code>allow</code> attribute is mandatory,
4166 4167
        'yes' means allow, 'no' for deny.
      </dd>
4168 4169
    </dl>

4170 4171 4172 4173 4174 4175 4176 4177 4178 4179 4180 4181 4182 4183 4184 4185
    <h4><a name="elementsSmartcard">Smartcard devices</a></h4>

    <p>
      A virtual smartcard device can be supplied to the guest via the
      <code>smartcard</code> element. A USB smartcard reader device on
      the host cannot be used on a guest with simple device
      passthrough, since it will then not be available on the host,
      possibly locking the host computer when it is "removed".
      Therefore, some hypervisors provide a specialized virtual device
      that can present a smartcard interface to the guest, with
      several modes for describing how credentials are obtained from
      the host or even a from a channel created to a third-party
      smartcard provider. <span class="since">Since 0.8.8</span>
    </p>

<pre>
4186 4187 4188 4189 4190 4191 4192 4193 4194 4195 4196 4197 4198 4199 4200 4201 4202
...
&lt;devices&gt;
  &lt;smartcard mode='host'/&gt;
  &lt;smartcard mode='host-certificates'&gt;
    &lt;certificate&gt;cert1&lt;/certificate&gt;
    &lt;certificate&gt;cert2&lt;/certificate&gt;
    &lt;certificate&gt;cert3&lt;/certificate&gt;
    &lt;database&gt;/etc/pki/nssdb/&lt;/database&gt;
  &lt;/smartcard&gt;
  &lt;smartcard mode='passthrough' type='tcp'&gt;
    &lt;source mode='bind' host='127.0.0.1' service='2001'/&gt;
    &lt;protocol type='raw'/&gt;
    &lt;address type='ccid' controller='0' slot='0'/&gt;
  &lt;/smartcard&gt;
  &lt;smartcard mode='passthrough' type='spicevmc'/&gt;
&lt;/devices&gt;
...
4203 4204 4205 4206 4207 4208 4209 4210 4211 4212 4213
</pre>

    <p>
      The <code>&lt;smartcard&gt;</code> element has a mandatory
      attribute <code>mode</code>.  The following modes are supported;
      in each mode, the guest sees a device on its USB bus that
      behaves like a physical USB CCID (Chip/Smart Card Interface
      Device) card.
    </p>

    <dl>
4214
      <dt><code>host</code></dt>
4215 4216 4217 4218 4219 4220
      <dd>The simplest operation, where the hypervisor relays all
      requests from the guest into direct access to the host's
      smartcard via NSS.  No other attributes or sub-elements are
      required.  See below about the use of an
      optional <code>&lt;address&gt;</code> sub-element.</dd>

4221
      <dt><code>host-certificates</code></dt>
4222 4223 4224 4225 4226 4227 4228 4229 4230 4231 4232 4233 4234
      <dd>Rather than requiring a smartcard to be plugged into the
      host, it is possible to provide three NSS certificate names
      residing in a database on the host.  These certificates can be
      generated via the command <code>certutil -d /etc/pki/nssdb -x -t
      CT,CT,CT -S -s CN=cert1 -n cert1</code>, and the resulting three
      certificate names must be supplied as the content of each of
      three <code>&lt;certificate&gt;</code> sub-elements.  An
      additional sub-element <code>&lt;database&gt;</code> can specify
      the absolute path to an alternate directory (matching
      the <code>-d</code> option of the <code>certutil</code> command
      when creating the certificates); if not present, it defaults to
      /etc/pki/nssdb.</dd>

4235
      <dt><code>passthrough</code></dt>
4236 4237 4238 4239 4240 4241 4242
      <dd>Rather than having the hypervisor directly communicate with
      the host, it is possible to tunnel all requests through a
      secondary character device to a third-party provider (which may
      in turn be talking to a smartcard or using three certificate
      files).  In this mode of operation, an additional
      attribute <code>type</code> is required, matching one of the
      supported <a href="#elementsConsole">serial device</a> types, to
E
Eric Blake 已提交
4243 4244 4245 4246 4247
      describe the host side of the tunnel; <code>type='tcp'</code>
      or <code>type='spicevmc'</code> (which uses the smartcard
      channel of a <a href="#elementsGraphics">SPICE graphics
      device</a>) are typical.  Further sub-elements, such
      as <code>&lt;source&gt;</code>, may be required according to the
4248 4249 4250 4251 4252 4253 4254 4255 4256
      given type, although a <code>&lt;target&gt;</code> sub-element
      is not required (since the consumer of the character device is
      the hypervisor itself, rather than a device visible in the
      guest).</dd>
    </dl>

    <p>
      Each mode supports an optional
      sub-element <code>&lt;address&gt;</code>, which fine-tunes the
4257 4258 4259
      correlation between the smartcard and a ccid bus
      controller, <a href="#elementsAddress">documented above</a>.
      For now, qemu only supports at most one
4260 4261 4262
      smartcard, with an address of bus=0 slot=0.
    </p>

D
Daniel P. Berrange 已提交
4263 4264
    <h4><a name="elementsNICS">Network interfaces</a></h4>

4265
<pre>
4266 4267 4268 4269 4270 4271 4272 4273 4274 4275
...
&lt;devices&gt;
  &lt;interface type='direct' trustGuestRxFilters='yes'&gt;
    &lt;source dev='eth0'/&gt;
    &lt;mac address='52:54:00:5d:c7:9e'/&gt;
    &lt;boot order='1'/&gt;
    &lt;rom bar='off'/&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
4276

E
Eric Blake 已提交
4277 4278 4279
    <p>
      There are several possibilities for specifying a network
      interface visible to the guest.  Each subsection below provides
4280 4281 4282 4283 4284 4285 4286 4287 4288 4289 4290 4291
      more details about common setup options.
    </p>
    <p>
      <span class="since">Since 1.2.10</span>),
      the <code>interface</code> element
      property <code>trustGuestRxFilters</code> provides the
      capability for the host to detect and trust reports from the
      guest regarding changes to the interface mac address and receive
      filters by setting the attribute to <code>yes</code>. The default
      setting for the attribute is <code>no</code> for security
      reasons and support depends on the guest network device model as
      well as the type of connection on the host - currently it is
C
Chen Fan 已提交
4292
      only supported for the virtio device model and for macvtap
4293 4294 4295 4296
      connections on the host.
    </p>
    <p>
      Each <code>&lt;interface&gt;</code> element has an
E
Eric Blake 已提交
4297 4298
      optional <code>&lt;address&gt;</code> sub-element that can tie
      the interface to a particular pci slot, with
4299 4300
      attribute <code>type='pci'</code>
      as <a href="#elementsAddress">documented above</a>.
E
Eric Blake 已提交
4301 4302
    </p>

D
Daniel P. Berrange 已提交
4303 4304 4305 4306 4307
    <h5><a name="elementsNICSVirtual">Virtual network</a></h5>

    <p>
      <strong><em>
      This is the recommended config for general guest connectivity on
4308 4309 4310 4311
      hosts with dynamic / wireless networking configs (or multi-host
      environments where the host hardware details are described
      separately in a <code>&lt;network&gt;</code>
      definition <span class="since">Since 0.9.4</span>).
D
Daniel P. Berrange 已提交
4312 4313 4314 4315
      </em></strong>
    </p>

    <p>
4316 4317 4318 4319 4320 4321 4322 4323 4324 4325 4326 4327 4328 4329 4330 4331 4332 4333 4334 4335 4336 4337 4338 4339 4340 4341 4342

      Provides a connection whose details are described by the named
      network definition. Depending on the virtual network's "forward
      mode" configuration, the network may be totally isolated
      (no <code>&lt;forward&gt;</code> element given), NAT'ing to an
      explicit network device or to the default route
      (<code>&lt;forward mode='nat'&gt;</code>), routed with no NAT
      (<code>&lt;forward mode='route'/&gt;</code>), or connected
      directly to one of the host's network interfaces (via macvtap)
      or bridge devices ((<code>&lt;forward
      mode='bridge|private|vepa|passthrough'/&gt;</code> <span class="since">Since
      0.9.4</span>)
    </p>
    <p>
      For networks with a forward mode of bridge, private, vepa, and
      passthrough, it is assumed that the host has any necessary DNS
      and DHCP services already setup outside the scope of libvirt. In
      the case of isolated, nat, and routed networks, DHCP and DNS are
      provided on the virtual network by libvirt, and the IP range can
      be determined by examining the virtual network config with
      '<code>virsh net-dumpxml [networkname]</code>'. There is one
      virtual network called 'default' setup out of the box which does
      NAT'ing to the default route and has an IP range
      of <code>192.168.122.0/255.255.255.0</code>. Each guest will
      have an associated tun device created with a name of vnetN,
      which can also be overridden with the &lt;target&gt; element
      (see
4343
      <a href="#elementsNICSTargetOverride">overriding the target element</a>).
D
Daniel P. Berrange 已提交
4344
    </p>
4345 4346 4347 4348 4349 4350
    <p>
      When the source of an interface is a network,
      a <code>portgroup</code> can be specified along with the name of
      the network; one network may have multiple portgroups defined,
      with each portgroup containing slightly different configuration
      information for different classes of network
4351 4352 4353 4354 4355 4356 4357 4358 4359 4360 4361 4362 4363 4364 4365 4366 4367 4368 4369
      connections. <span class="since">Since 0.9.4</span>.
    </p>
    <p>
      Also, similar to <code>direct</code> network connections
      (described below), a connection of type <code>network</code> may
      specify a <code>virtualport</code> element, with configuration
      data to be forwarded to a vepa (802.1Qbg) or 802.1Qbh compliant
      switch (<span class="since">Since 0.8.2</span>), or to an
      Open vSwitch virtual switch (<span class="since">Since
      0.9.11</span>).
    </p>
    <p>
      Since the actual type of switch may vary depending on the
      configuration in the <code>&lt;network&gt;</code> on the host,
      it is acceptable to omit the virtualport <code>type</code>
      attribute, and specify attributes from multiple different
      virtualport types (and also to leave out certain attributes); at
      domain startup time, a complete <code>&lt;virtualport&gt;</code>
      element will be constructed by merging together the type and
G
Guannan Ren 已提交
4370 4371 4372 4373 4374
      attributes defined in the network and the portgroup referenced
      by the interface. The newly-constructed virtualport is a combination
      of them. The attributes from lower virtualport can't make change
      on the ones defined in higher virtualport.
      Interface takes the highest priority, portgroup is lowest priority.
4375 4376 4377
      (<span class="since">Since 0.10.0</span>). For example, in order
      to work properly with both an 802.1Qbh switch and an Open vSwitch
      switch, you may choose to specify no type, but both
G
Guannan Ren 已提交
4378
      an <code>profileid</code> (in case the switch is 802.1Qbh) and
4379 4380 4381 4382 4383 4384 4385 4386 4387
      an <code>interfaceid</code> (in case the switch is Open vSwitch)
      (you may also omit the other attributes, such as managerid,
      typeid, or profileid, to be filled in from the
      network's <code>&lt;virtualport&gt;</code>). If you want to
      limit a guest to connecting only to certain types of switches,
      you can specify the virtualport type, but still omit some/all of
      the parameters - in this case if the host's network has a
      different type of virtualport, connection of the interface will
      fail.
4388
    </p>
D
Daniel P. Berrange 已提交
4389

4390
<pre>
4391 4392 4393 4394 4395
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
  &lt;/interface&gt;
4396
  ...
4397 4398 4399 4400 4401 4402 4403 4404 4405 4406 4407
  &lt;interface type='network'&gt;
    &lt;source network='default' portgroup='engineering'/&gt;
    &lt;target dev='vnet7'/&gt;
    &lt;mac address="00:11:22:33:44:55"/&gt;
    &lt;virtualport&gt;
      &lt;parameters instanceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/&gt;
    &lt;/virtualport&gt;

  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
4408

D
Dan Kenigsberg 已提交
4409
    <h5><a name="elementsNICSBridge">Bridge to LAN</a></h5>
D
Daniel P. Berrange 已提交
4410 4411 4412 4413

    <p>
      <strong><em>
      This is the recommended config for general guest connectivity on
4414
      hosts with static wired networking configs.
D
Daniel P. Berrange 已提交
4415 4416 4417 4418
      </em></strong>
    </p>

    <p>
E
Eric Blake 已提交
4419
      Provides a bridge from the VM directly to the LAN. This assumes
D
Daniel P. Berrange 已提交
4420 4421 4422
      there is a bridge device on the host which has one or more of the hosts
      physical NICs enslaved. The guest VM will have an associated tun device
      created with a name of vnetN, which can also be overridden with the
4423 4424 4425 4426 4427
      &lt;target&gt; element (see
      <a href="#elementsNICSTargetOverride">overriding the target element</a>).
      The tun device will be enslaved to the bridge. The IP range / network
      configuration is whatever is used on the LAN. This provides the guest VM
      full incoming &amp; outgoing net access just like a physical machine.
D
Daniel P. Berrange 已提交
4428
    </p>
4429 4430 4431
    <p>
      On Linux systems, the bridge device is normally a standard Linux
      host bridge. On hosts that support Open vSwitch, it is also
4432
      possible to connect to an Open vSwitch bridge device by adding
4433 4434 4435 4436 4437 4438
      a <code>&lt;virtualport type='openvswitch'/&gt;</code> to the
      interface definition.  (<span class="since">Since
      0.9.11</span>). The Open vSwitch type virtualport accepts two
      parameters in its <code>&lt;parameters&gt;</code> element -
      an <code>interfaceid</code> which is a standard uuid used to
      uniquely identify this particular interface to Open vSwitch (if
C
Chen Hanxiao 已提交
4439
      you do not specify one, a random interfaceid will be generated
4440 4441 4442 4443
      for you when you first define the interface), and an
      optional <code>profileid</code> which is sent to Open vSwitch as
      the interfaces "port-profile".
    </p>
4444
<pre>
4445 4446
...
&lt;devices&gt;
4447
  ...
4448 4449 4450 4451 4452 4453 4454 4455 4456 4457 4458 4459 4460 4461 4462 4463 4464
  &lt;interface type='bridge'&gt;
    &lt;source bridge='br0'/&gt;
  &lt;/interface&gt;
  &lt;interface type='bridge'&gt;
    &lt;source bridge='br1'/&gt;
    &lt;target dev='vnet7'/&gt;
    &lt;mac address="00:11:22:33:44:55"/&gt;
  &lt;/interface&gt;
  &lt;interface type='bridge'&gt;
    &lt;source bridge='ovsbr'/&gt;
    &lt;virtualport type='openvswitch'&gt;
      &lt;parameters profileid='menial' interfaceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/&gt;
    &lt;/virtualport&gt;
  &lt;/interface&gt;
  ...
&lt;/devices&gt;
...</pre>
4465 4466 4467 4468 4469 4470 4471 4472 4473 4474 4475 4476 4477 4478

    <p>
      On hosts that support Open vSwitch on the kernel side and have the
      Midonet Host Agent configured, it is also possible to connect to the
      'midonet' bridge device by adding a
      <code>&lt;virtualport type='midonet'/&gt;</code> to the
      interface definition.  (<span class="since">Since
      1.2.13</span>). The Midonet virtualport type requires an
      <code>interfaceid</code> attribute in its
      <code>&lt;parameters&gt;</code> element. This interface id is the UUID
      that specifies which port in the virtual network topology will be bound
      to the interface.
    </p>
<pre>
4479 4480
...
&lt;devices&gt;
4481
  ...
4482 4483 4484 4485 4486 4487 4488 4489 4490 4491 4492 4493 4494 4495 4496 4497 4498
  &lt;interface type='bridge'&gt;
    &lt;source bridge='br0'/&gt;
  &lt;/interface&gt;
  &lt;interface type='bridge'&gt;
    &lt;source bridge='br1'/&gt;
    &lt;target dev='vnet7'/&gt;
    &lt;mac address="00:11:22:33:44:55"/&gt;
  &lt;/interface&gt;
  &lt;interface type='bridge'&gt;
    &lt;source bridge='midonet'/&gt;
    &lt;virtualport type='midonet'&gt;
      &lt;parameters interfaceid='0b2d64da-3d0e-431e-afdd-804415d6ebbb'/&gt;
    &lt;/virtualport&gt;
  &lt;/interface&gt;
  ...
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
4499 4500 4501 4502 4503 4504 4505 4506 4507 4508 4509 4510

    <h5><a name="elementsNICSSlirp">Userspace SLIRP stack</a></h5>

    <p>
      Provides a virtual LAN with NAT to the outside world. The virtual
      network has DHCP &amp; DNS services and will give the guest VM addresses
      starting from <code>10.0.2.15</code>. The default router will be
      <code>10.0.2.2</code> and the DNS server will be <code>10.0.2.3</code>.
      This networking is the only option for unprivileged users who need their
      VMs to have outgoing access.
    </p>

4511
<pre>
4512 4513 4514
...
&lt;devices&gt;
  &lt;interface type='user'/&gt;
4515
  ...
4516 4517 4518 4519 4520
  &lt;interface type='user'&gt;
    &lt;mac address="00:11:22:33:44:55"/&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
4521 4522 4523 4524 4525 4526 4527 4528 4529 4530 4531 4532 4533 4534


    <h5><a name="elementsNICSEthernet">Generic ethernet connection</a></h5>

    <p>
      Provides a means for the administrator to execute an arbitrary script
      to connect the guest's network to the LAN. The guest will have a tun
      device created with a name of vnetN, which can also be overridden with the
      &lt;target&gt; element. After creating the tun device a shell script will
      be run which is expected to do whatever host network integration is
      required. By default this script is called /etc/qemu-ifup but can be
      overridden.
    </p>

4535
<pre>
4536 4537 4538
...
&lt;devices&gt;
  &lt;interface type='ethernet'/&gt;
4539
  ...
4540 4541 4542 4543 4544 4545
  &lt;interface type='ethernet'&gt;
    &lt;target dev='vnet7'/&gt;
    &lt;script path='/etc/qemu-ifup-mynet'/&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
4546

4547 4548 4549 4550
    <h5><a name="elementsNICSDirect">Direct attachment to physical interface</a></h5>

    <p>
      Provides direct attachment of the virtual machine's NIC to the given
4551
      physical interface of the host.
E
Eric Blake 已提交
4552
      <span class="since">Since 0.7.7 (QEMU and KVM only)</span><br/>
4553 4554 4555
      This setup requires the Linux macvtap
      driver to be available. <span class="since">(Since Linux 2.6.34.)</span>
      One of the modes 'vepa'
4556
      ( <a href="http://www.ieee802.org/1/files/public/docs2009/new-evb-congdon-vepa-modular-0709-v01.pdf">
4557
      'Virtual Ethernet Port Aggregator'</a>), 'bridge' or 'private'
4558
      can be chosen for the operation mode of the macvtap device, 'vepa'
4559 4560
      being the default mode. The individual modes cause the delivery of
      packets to behave as follows:
4561
    </p>
4562 4563 4564 4565 4566 4567 4568 4569 4570 4571 4572 4573
    <p>
      If the model type is set to <code>virtio</code> and
      interface's <code>trustGuestRxFilters</code> attribute is set
      to <code>yes</code>, changes made to the interface mac address,
      unicast/multicast receive filters, and vlan settings in the
      guest will be monitored and propagated to the associated macvtap
      device on the host (<span class="since">Since
      1.2.10</span>). If <code>trustGuestRxFilters</code> is not set,
      or is not supported for the device model in use, an attempted
      change to the mac address originating from the guest side will
      result in a non-working network connection.
    </p>
4574

4575 4576 4577 4578 4579 4580 4581 4582 4583 4584 4585
    <dl>
      <dt><code>vepa</code></dt>
      <dd>All VMs' packets are sent to the external bridge. Packets
      whose destination is a VM on the same host as where the
      packet originates from are sent back to the host by the VEPA
      capable bridge (today's bridges are typically not VEPA capable).</dd>
      <dt><code>bridge</code></dt>
      <dd>Packets whose destination is on the same host as where they
      originate from are directly delivered to the target macvtap device.
      Both origin and destination devices need to be in bridge mode
      for direct delivery. If either one of them is in <code>vepa</code> mode,
E
Eric Blake 已提交
4586
      a VEPA capable bridge is required.</dd>
4587 4588 4589 4590 4591 4592
      <dt><code>private</code></dt>
      <dd>All packets are sent to the external bridge and will only be
      delivered to a target VM on the same host if they are sent through an
      external router or gateway and that device sends them back to the
      host. This procedure is followed if either the source or destination
      device is in <code>private</code> mode.</dd>
4593 4594 4595 4596 4597 4598 4599
      <dt><code>passthrough</code></dt>
      <dd>This feature attaches a virtual function of a SRIOV capable
      NIC directly to a VM without losing the migration capability.
      All packets are sent to the VF/IF of the configured network device.
      Depending on the capabilities of the device additional prerequisites or
      limitations may apply; for example, on Linux this requires
      kernel 2.6.38 or newer. <span class="since">Since 0.9.2</span></dd>
4600 4601
    </dl>

4602
<pre>
4603 4604
...
&lt;devices&gt;
4605
  ...
4606 4607 4608 4609 4610
  &lt;interface type='direct' trustGuestRxFilters='no'&gt;
    &lt;source dev='eth0' mode='vepa'/&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
4611

4612 4613 4614 4615
    <p>
      The network access of direct attached virtual machines can be
      managed by the hardware switch to which the physical interface
      of the host machine is connected to.
E
Eric Blake 已提交
4616
    </p>
4617 4618 4619 4620 4621 4622 4623
    <p>
      The interface can have additional parameters as shown below,
      if the switch is conforming to the IEEE 802.1Qbg standard.
      The parameters of the virtualport element are documented in more detail
      in the IEEE 802.1Qbg standard. The values are network specific and
      should be provided by the network administrator. In 802.1Qbg terms,
      the Virtual Station Interface (VSI) represents the virtual interface
4624
      of a virtual machine. <span class="since">Since 0.8.2</span>
4625
    </p>
4626 4627 4628 4629
    <p>
      Please note that IEEE 802.1Qbg requires a non-zero value for the
      VLAN ID.
    </p>
4630 4631 4632 4633 4634 4635 4636 4637 4638 4639 4640 4641 4642 4643 4644 4645 4646 4647 4648 4649 4650
    <dl>
      <dt><code>managerid</code></dt>
      <dd>The VSI Manager ID identifies the database containing the VSI type
        and instance definitions. This is an integer value and the
        value 0 is reserved.</dd>
      <dt><code>typeid</code></dt>
      <dd>The VSI Type ID identifies a VSI type characterizing the network
        access. VSI types are typically managed by network administrator.
        This is an integer value.
      </dd>
      <dt><code>typeidversion</code></dt>
      <dd>The VSI Type Version allows multiple versions of a VSI Type.
        This is an integer value.
      </dd>
      <dt><code>instanceid</code></dt>
      <dd>The VSI Instance ID Identifier is generated when a VSI instance
        (i.e. a virtual interface of a virtual machine) is created.
        This is a globally unique identifier.
      </dd>
    </dl>
<pre>
4651 4652
...
&lt;devices&gt;
4653
  ...
4654 4655 4656 4657 4658 4659 4660 4661
  &lt;interface type='direct'&gt;
    &lt;source dev='eth0.2' mode='vepa'/&gt;
    &lt;virtualport type="802.1Qbg"&gt;
      &lt;parameters managerid="11" typeid="1193047" typeidversion="2" instanceid="09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f"/&gt;
    &lt;/virtualport&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
4662

4663 4664 4665 4666 4667 4668 4669 4670 4671
    <p>
      The interface can have additional parameters as shown below
      if the switch is conforming to the IEEE 802.1Qbh standard.
      The values are network specific and should be provided by the
      network administrator. <span class="since">Since 0.8.2</span>
    </p>
    <dl>
      <dt><code>profileid</code></dt>
      <dd>The profile ID contains the name of the port profile that is to
E
Eric Blake 已提交
4672
        be applied to this interface.  This name is resolved by the port
4673 4674 4675 4676 4677
        profile database into the network parameters from the port profile,
        and those network parameters will be applied to this interface.
      </dd>
    </dl>
  <pre>
4678 4679
...
&lt;devices&gt;
4680
  ...
4681 4682 4683 4684 4685 4686 4687 4688 4689
  &lt;interface type='direct'&gt;
    &lt;source dev='eth0' mode='private'/&gt;
    &lt;virtualport type='802.1Qbh'&gt;
      &lt;parameters profileid='finance'/&gt;
    &lt;/virtualport&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...
</pre>
4690

4691 4692 4693 4694 4695 4696 4697 4698

    <h5><a name="elementsNICSHostdev">PCI Passthrough</a></h5>

    <p>
      A PCI network device (specified by the &lt;source&gt; element)
      is directly assigned to the guest using generic device
      passthrough, after first optionally setting the device's MAC
      address to the configured value, and associating the device with
4699
      an 802.1Qbh capable switch using an optionally specified
4700
      &lt;virtualport&gt; element (see the examples of virtualport
4701 4702 4703 4704 4705 4706 4707 4708 4709
      given above for type='direct' network devices). Note that - due
      to limitations in standard single-port PCI ethernet card driver
      design - only SR-IOV (Single Root I/O Virtualization) virtual
      function (VF) devices can be assigned in this manner; to assign
      a standard single-port PCI or PCIe ethernet card to a guest, use
      the traditional &lt;hostdev&gt; device definition and
      <span class="since">Since 0.9.11</span>
    </p>

4710 4711 4712 4713 4714 4715 4716 4717 4718 4719 4720 4721
    <p>
      To use VFIO device assignment rather than traditional/legacy KVM
      device assignment (VFIO is a new method of device assignment
      that is compatible with UEFI Secure Boot), a type='hostdev'
      interface can have an optional <code>driver</code> sub-element
      with a <code>name</code> attribute set to "vfio". To use legacy
      KVM device assignment you can set <code>name</code> to "kvm" (or
      simply omit the <code>&lt;driver&gt;</code> element, since "kvm"
      is currently the default).
      <span class="since">Since 1.0.5 (QEMU and KVM only, requires kernel 3.6 or newer)</span>
    </p>

4722 4723 4724 4725 4726 4727 4728 4729 4730 4731 4732 4733 4734 4735
    <p>
      Note that this "intelligent passthrough" of network devices is
      very similar to the functionality of a standard &lt;hostdev&gt;
      device, the difference being that this method allows specifying
      a MAC address and &lt;virtualport&gt; for the passed-through
      device. If these capabilities are not required, if you have a
      standard single-port PCI, PCIe, or USB network card that doesn't
      support SR-IOV (and hence would anyway lose the configured MAC
      address during reset after being assigned to the guest domain),
      or if you are using a version of libvirt older than 0.9.11, you
      should use standard &lt;hostdev&gt; to assign the device to the
      guest instead of &lt;interface type='hostdev'/&gt;.
    </p>

4736 4737 4738 4739 4740 4741
    <p>
      Similar to the functionality of a standard &lt;hostdev&gt; device,
      when <code>managed</code> is "yes", it is detached from the host
      before being passed on to the guest, and reattached to the host
      after the guest exits. If <code>managed</code> is omitted or "no",
      the user is responsible to call <code>virNodeDeviceDettach</code>
J
John Ferlan 已提交
4742
      (or <code>virsh nodedev-detach</code>) before starting the guest
4743 4744 4745 4746 4747
      or hot-plugging the device, and <code>virNodeDeviceReAttach</code>
      (or <code>virsh nodedev-reattach</code>) after hot-unplug or
      stopping the guest.
    </p>

4748
<pre>
4749 4750 4751 4752 4753 4754 4755 4756 4757 4758 4759 4760 4761 4762
...
&lt;devices&gt;
  &lt;interface type='hostdev' managed='yes'&gt;
    &lt;driver name='vfio'/&gt;
    &lt;source&gt;
      &lt;address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/&gt;
    &lt;/source&gt;
    &lt;mac address='52:54:00:6d:90:02'/&gt;
    &lt;virtualport type='802.1Qbh'&gt;
      &lt;parameters profileid='finance'/&gt;
    &lt;/virtualport&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
4763 4764


D
Daniel P. Berrange 已提交
4765 4766 4767 4768 4769 4770 4771 4772 4773 4774 4775 4776 4777 4778
    <h5><a name="elementsNICSMulticast">Multicast tunnel</a></h5>

    <p>
      A multicast group is setup to represent a virtual network. Any VMs
      whose network devices are in the same multicast group can talk to each
      other even across hosts. This mode is also available to unprivileged
      users. There is no default DNS or DHCP support and no outgoing network
      access. To provide outgoing network access, one of the VMs should have a
      2nd NIC which is connected to one of the first 4 network types and do the
      appropriate routing. The multicast protocol is compatible with that used
      by user mode linux guests too. The source address used must be from the
      multicast address block.
    </p>

4779
<pre>
4780 4781 4782 4783 4784 4785 4786 4787
...
&lt;devices&gt;
  &lt;interface type='mcast'&gt;
    &lt;mac address='52:54:00:6d:90:01'/&gt;
    &lt;source address='230.0.0.1' port='5558'/&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
4788 4789 4790 4791 4792 4793 4794 4795 4796 4797 4798 4799

    <h5><a name="elementsNICSTCP">TCP tunnel</a></h5>

    <p>
      A TCP client/server architecture provides a virtual network. One VM
      provides the server end of the network, all other VMS are configured as
      clients. All network traffic is routed between the VMs via the server.
      This mode is also available to unprivileged users. There is no default
      DNS or DHCP support and no outgoing network access. To provide outgoing
      network access, one of the VMs should have a 2nd NIC which is connected
      to one of the first 4 network types and do the appropriate routing.</p>

4800
<pre>
4801 4802 4803 4804 4805 4806
...
&lt;devices&gt;
  &lt;interface type='server'&gt;
    &lt;mac address='52:54:00:22:c9:42'/&gt;
    &lt;source address='192.168.0.1' port='5558'/&gt;
  &lt;/interface&gt;
4807
  ...
4808 4809 4810 4811 4812 4813
  &lt;interface type='client'&gt;
    &lt;mac address='52:54:00:8b:c9:51'/&gt;
    &lt;source address='192.168.0.1' port='5558'/&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
4814 4815 4816 4817 4818 4819 4820 4821 4822 4823 4824 4825 4826 4827

    <h5><a name="elementsNICSUDP">UDP unicast tunnel</a></h5>

    <p>
    A UDP unicast architecture provides a virtual network which enables
    connections between QEMU instances using QEMU's UDP infrastructure.

    The xml "source" address is the endpoint address to which the UDP socket
    packets will be sent from the host running QEMU.
    The xml "local" address is the address of the interface from which the
    UDP socket packets will originate from the QEMU host.
    <span class="since">Since 1.2.20</span></p>

<pre>
4828 4829 4830 4831 4832 4833 4834 4835 4836 4837
...
&lt;devices&gt;
  &lt;interface type='udp'&gt;
    &lt;mac address='52:54:00:22:c9:42'/&gt;
    &lt;source address='127.0.0.1' port='11115'&gt;
      &lt;local address='127.0.0.1' port='11116'/&gt;
    &lt;/source&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
4838

4839 4840
    <h5><a name="elementsNICSModel">Setting the NIC model</a></h5>

4841
<pre>
4842 4843 4844 4845 4846 4847 4848 4849 4850
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet1'/&gt;
    <b>&lt;model type='ne2k_pci'/&gt;</b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
4851 4852 4853 4854 4855 4856 4857 4858 4859 4860 4861 4862 4863 4864 4865 4866 4867 4868 4869 4870 4871 4872

    <p>
      For hypervisors which support this, you can set the model of
      emulated network interface card.
    </p>

    <p>
      The values for <code>type</code> aren't defined specifically by
      libvirt, but by what the underlying hypervisor supports (if
      any).  For QEMU and KVM you can get a list of supported models
      with these commands:
    </p>

<pre>
qemu -net nic,model=? /dev/null
qemu-kvm -net nic,model=? /dev/null
</pre>

    <p>
      Typical values for QEMU and KVM include:
      ne2k_isa i82551 i82557b i82559er ne2k_pci pcnet rtl8139 e1000 virtio
    </p>
D
Daniel P. Berrange 已提交
4873

4874 4875 4876
    <h5><a name="elementsDriverBackendOptions">Setting NIC driver-specific options</a></h5>

<pre>
4877 4878 4879 4880 4881 4882 4883 4884 4885 4886 4887 4888 4889 4890
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet1'/&gt;
    &lt;model type='virtio'/&gt;
    <b>&lt;driver name='vhost' txmode='iothread' ioeventfd='on' event_idx='off' queues='5' rx_queue_size='256'&gt;
      &lt;host csum='off' gso='off' tso4='off' tso6='off' ecn='off' ufo='off' mrg_rxbuf='off'/&gt;
      &lt;guest csum='off' tso4='off' tso6='off' ecn='off' ufo='off'/&gt;
    &lt;/driver&gt;
    </b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
4891 4892 4893 4894 4895 4896 4897 4898 4899

    <p>
      Some NICs may have tunable driver-specific options. These are
      set as attributes of the <code>driver</code> sub-element of the
      interface definition. Currently the following attributes are
      available for the <code>"virtio"</code> NIC driver:
    </p>

    <dl>
4900 4901 4902 4903 4904 4905 4906 4907 4908 4909 4910 4911
      <dt><code>name</code></dt>
      <dd>
        The optional <code>name</code> attribute forces which type of
        backend driver to use. The value can be either 'qemu' (a
        user-space backend) or 'vhost' (a kernel backend, which
        requires the vhost module to be provided by the kernel); an
        attempt to require the vhost driver without kernel support
        will be rejected.  If this attribute is not present, then the
        domain defaults to 'vhost' if present, but silently falls back
        to 'qemu' without error.
        <span class="since">Since 0.8.8 (QEMU and KVM only)</span>
      </dd>
4912 4913 4914 4915 4916 4917 4918 4919 4920 4921 4922 4923
      <dd>
        For interfaces of type='hostdev' (PCI passthrough devices)
        the <code>name</code> attribute can optionally be set to
        "vfio" or "kvm". "vfio" tells libvirt to use VFIO device
        assignment rather than traditional KVM device assignment (VFIO
        is a new method of device assignment that is compatible with
        UEFI Secure Boot), and "kvm" tells libvirt to use the legacy
        device assignment performed directly by the kvm kernel module
        (the default is currently "kvm", but is subject to change).
        <span class="since">Since 1.0.5 (QEMU and KVM only, requires
        kernel 3.6 or newer)</span>
      </dd>
4924 4925 4926 4927 4928
      <dd>
        For interfaces of type='vhostuser', the <code>name</code>
        attribute is ignored. The backend driver used is always
        vhost-user.
      </dd>
4929

4930 4931 4932 4933 4934
      <dt><code>txmode</code></dt>
      <dd>
        The <code>txmode</code> attribute specifies how to handle
        transmission of packets when the transmit buffer is full. The
        value can be either 'iothread' or 'timer'.
E
Eric Blake 已提交
4935
        <span class="since">Since 0.8.8 (QEMU and KVM only)</span><br/><br/>
4936 4937 4938 4939

        If set to 'iothread', packet tx is all done in an iothread in
        the bottom half of the driver (this option translates into
        adding "tx=bh" to the qemu commandline -device virtio-net-pci
E
Eric Blake 已提交
4940
        option).<br/><br/>
4941 4942 4943 4944

        If set to 'timer', tx work is done in qemu, and if there is
        more tx data than can be sent at the present time, a timer is
        set before qemu moves on to do other things; when the timer
E
Eric Blake 已提交
4945
        fires, another attempt is made to send more data.<br/><br/>
4946 4947 4948 4949 4950

        The resulting difference, according to the qemu developer who
        added the option is: "bh makes tx more asynchronous and reduces
        latency, but potentially causes more processor bandwidth
        contention since the cpu doing the tx isn't necessarily the
E
Eric Blake 已提交
4951
        cpu where the guest generated the packets."<br/><br/>
4952

4953 4954 4955 4956 4957 4958 4959 4960 4961 4962 4963 4964 4965 4966 4967 4968
        <b>In general you should leave this option alone, unless you
        are very certain you know what you are doing.</b>
      </dd>
      <dt><code>ioeventfd</code></dt>
      <dd>
        This optional attribute allows users to set
        <a href='https://patchwork.kernel.org/patch/43390/'>
        domain I/O asynchronous handling</a> for interface device.
        The default is left to the discretion of the hypervisor.
        Accepted values are "on" and "off". Enabling this allows
        qemu to execute VM while a separate thread handles I/O.
        Typically guests experiencing high system CPU utilization
        during I/O will benefit from this. On the other hand,
        on overloaded host it could increase guest I/O latency.
        <span class="since">Since 0.9.3 (QEMU and KVM only)</span><br/><br/>

4969
        <b>In general you should leave this option alone, unless you
4970 4971 4972 4973 4974 4975
        are very certain you know what you are doing.</b>
      </dd>
      <dt><code>event_idx</code></dt>
      <dd>
        The <code>event_idx</code> attribute controls some aspects of
        device event processing. The value can be either 'on' or 'off'
4976
        - if it is on, it will reduce the number of interrupts and
4977 4978 4979 4980 4981 4982 4983
        exits for the guest. The default is determined by QEMU;
        usually if the feature is supported, default is on. In case
        there is a situation where this behavior is suboptimal, this
        attribute provides a way to force the feature off.
        <span class="since">Since 0.9.5 (QEMU and KVM only)</span><br/><br/>

        <b>In general you should leave this option alone, unless you
4984 4985
        are very certain you know what you are doing.</b>
      </dd>
4986 4987
      <dt><code>queues</code></dt>
      <dd>
4988 4989 4990 4991 4992 4993 4994
        The optional <code>queues</code> attribute controls the number
        of queues to be used for either
        <a href="http://www.linux-kvm.org/page/Multiqueue"> Multiqueue
        virtio-net</a> or <a href="#elementVhostuser">vhost-user</a> network
        interfaces.  Use of multiple packet processing queues requires the
        interface having the <code>&lt;model type='virtio'/&gt;</code>
        element.  Each queue will potentially be handled by a different
4995
        processor, resulting in much higher throughput.
4996
        <span class="since">virtio-net since 1.0.6 (QEMU and KVM only)</span>
4997
        <span class="since">vhost-user since 1.2.17 (QEMU and KVM only)</span>
4998
      </dd>
4999 5000 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5012
      <dt><code>rx_queue_size</code></dt>
      <dd>
        The optional <code>rx_queue_size</code> attribute controls
        the size of virtio ring for each queue as described above.
        The default value is hypervisor dependent and may change
        across its releases. Moreover, some hypervisors may pose
        some restrictions on actual value. For instance, latest
        QEMU (as of 2016-09-01) requires value to be a power of two
        from [256, 1024] range.
        <span class="since">Since 2.3.0 (QEMU and KVM only)</span><br/><br/>

        <b>In general you should leave this option alone, unless you
        are very certain you know what you are doing.</b>
      </dd>
5013 5014 5015 5016 5017 5018 5019
    </dl>
    <p>
      Offloading options for the host and guest can be configured using
      the following sub-elements:
    </p>
    <dl>
      <dt><code>host</code></dt>
5020 5021 5022 5023 5024 5025 5026
      <dd>
        The <code>csum</code>, <code>gso</code>, <code>tso4</code>,
        <code>tso6</code>, <code>ecn</code> and <code>ufo</code>
        attributes with possible values <code>on</code>
        and <code>off</code> can be used to turn off host offloading options.
        By default, the supported offloads are enabled by QEMU.
        <span class="since">Since 1.2.9 (QEMU only)</span>
5027 5028 5029 5030
        The <code>mrg_rxbuf</code> attribute can be used to control
        mergeable rx buffers on the host side. Possible values are
        <code>on</code> (default) and <code>off</code>.
        <span class="since">Since 1.2.13 (QEMU only)</span>
5031
      </dd>
5032
      <dt><code>guest</code></dt>
5033 5034 5035 5036 5037 5038 5039 5040
      <dd>
        The <code>csum</code>, <code>tso4</code>,
        <code>tso6</code>, <code>ecn</code> and <code>ufo</code>
        attributes with possible values <code>on</code>
        and <code>off</code> can be used to turn off guest offloading options.
        By default, the supported offloads are enabled by QEMU.
        <span class="since">Since 1.2.9 (QEMU only)</span>
      </dd>
5041 5042
    </dl>

5043 5044 5045
    <h5><a name="elementsBackendOptions">Setting network backend-specific options</a></h5>

<pre>
5046 5047 5048 5049 5050 5051 5052 5053
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet1'/&gt;
    &lt;model type='virtio'/&gt;
    <b>&lt;backend tap='/dev/net/tun' vhost='/dev/vhost-net'/&gt;</b>
    &lt;driver name='vhost' txmode='iothread' ioeventfd='on' event_idx='off' queues='5'/&gt;
M
Michal Privoznik 已提交
5054 5055 5056
    <b>&lt;tune&gt;
      &lt;sndbuf&gt;1600&lt;/sndbuf&gt;
    &lt;/tune&gt;</b>
5057 5058 5059
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5060 5061 5062

    <p>
      For tuning the backend of the network, the <code>backend</code> element
5063 5064
      can be used. The <code>vhost</code> attribute can override the default vhost
      device path (<code>/dev/vhost-net</code>) for devices with <code>virtio</code> model.
5065 5066
      The <code>tap</code> attribute overrides the tun/tap device path (default:
      <code>/dev/net/tun</code>) for network and bridge interfaces. This does not work
M
Michal Privoznik 已提交
5067 5068 5069 5070 5071 5072
      in session mode. <span class="since">Since 1.2.9</span>
    </p>
    <p>
      For tap devices there is also <code>sndbuf</code> element which can
      adjust the size of send buffer in the host. <span class="since">Since
      0.8.8</span>
5073
    </p>
5074 5075
    <h5><a name="elementsNICSTargetOverride">Overriding the target element</a></h5>

5076
<pre>
5077 5078 5079 5080 5081 5082 5083 5084
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    <b>&lt;target dev='vnet1'/&gt;</b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5085 5086

    <p>
E
Eric Blake 已提交
5087 5088
      If no target is specified, certain hypervisors will
      automatically generate a name for the created tun device. This
5089
      name can be manually specified, however the name <i>should not
E
Eric Blake 已提交
5090 5091
      start with either 'vnet' or 'vif'</i>, which are prefixes
      reserved by libvirt and certain hypervisors. Manually specified
5092
      targets using these prefixes may be ignored.
5093 5094
    </p>

5095 5096 5097 5098 5099 5100 5101 5102
    <p>
      Note that for LXC containers, this defines the name of the interface
      on the host side. <span class="since">Since 1.2.7</span>, to define
      the name of the device on the guest side, the <code>guest</code>
      element should be used, as in the following snippet:
    </p>

<pre>
5103 5104 5105 5106 5107 5108 5109 5110
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    <b>&lt;guest dev='myeth'/&gt;</b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5111

5112 5113 5114
    <h5><a name="elementsNICSBoot">Specifying boot order</a></h5>

<pre>
5115 5116 5117 5118 5119 5120 5121 5122 5123
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet1'/&gt;
    <b>&lt;boot order='1'/&gt;</b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5124 5125

    <p>
5126
      For hypervisors which support this, you can set a specific NIC to
5127 5128 5129 5130 5131 5132 5133 5134
      be used for network boot. The <code>order</code> attribute determines
      the order in which devices will be tried during boot sequence. The
      per-device <code>boot</code> elements cannot be used together with
      general boot elements in
      <a href="#elementsOSBIOS">BIOS bootloader</a> section.
      <span class="since">Since 0.8.8</span>
    </p>

5135 5136 5137
    <h5><a name="elementsNICSROM">Interface ROM BIOS configuration</a></h5>

<pre>
5138 5139 5140 5141 5142 5143 5144 5145 5146
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet1'/&gt;
    <b>&lt;rom bar='on' file='/etc/fake/boot.bin'/&gt;</b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5147 5148 5149 5150 5151 5152 5153 5154 5155 5156

    <p>
      For hypervisors which support this, you can change how a PCI Network
      device's ROM is presented to the guest. The <code>bar</code>
      attribute can be set to "on" or "off", and determines whether
      or not the device's ROM will be visible in the guest's memory
      map. (In PCI documentation, the "rombar" setting controls the
      presence of the Base Address Register for the ROM). If no rom
      bar is specified, the qemu default will be used (older
      versions of qemu used a default of "off", while newer qemus
5157 5158 5159 5160 5161 5162
      have a default of "on").
      The optional <code>file</code> attribute is used to point to a
      binary file to be presented to the guest as the device's ROM
      BIOS. This can be useful to provide an alternative boot ROM for a
      network device.
      <span class="since">Since 0.9.10 (QEMU and KVM only)</span>.
5163
    </p>
5164 5165
    <h5><a name="elementDomain">Setting up a network backend in a driver domain</a></h5>
<pre>
5166 5167
...
&lt;devices&gt;
5168
  ...
5169 5170 5171 5172 5173 5174 5175
  &lt;interface type='bridge'&gt;
    &lt;source bridge='br0'/&gt;
    <b>&lt;backenddomain name='netvm'/&gt;</b>
  &lt;/interface&gt;
  ...
&lt;/devices&gt;
...</pre>
5176 5177 5178 5179 5180 5181 5182 5183 5184 5185 5186

    <p>
      The optional <code>backenddomain</code> element allows specifying a
      backend domain (aka driver domain) for the interface. Use the
      <code>name</code> attribute to specify the backend domain name. You
      can use it to create a direct network link between domains (so data
      will not go through host system). Use with type 'ethernet' to create
      plain network link, or with type 'bridge' to connect to a bridge inside
      the backend domain.
      <span class="since">Since 1.2.13 (Xen only)</span>
    </p>
5187

5188 5189 5190
    <h5><a name="elementQoS">Quality of service</a></h5>

<pre>
5191 5192 5193 5194 5195 5196 5197 5198 5199 5200 5201 5202
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet0'/&gt;
    <b>&lt;bandwidth&gt;
      &lt;inbound average='1000' peak='5000' floor='200' burst='1024'/&gt;
      &lt;outbound average='128' peak='256' burst='256'/&gt;
    &lt;/bandwidth&gt;</b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5203 5204 5205

    <p>
      This part of interface XML provides setting quality of service. Incoming
J
John Ferlan 已提交
5206 5207 5208 5209
      and outgoing traffic can be shaped independently.
      The <code>bandwidth</code> element and its child elements are described
      in the <a href="formatnetwork.html#elementQoS">QoS</a> section of
      the Network XML.
5210 5211
    </p>

5212 5213 5214
    <h5><a name="elementVlanTag">Setting VLAN tag (on supported network types only)</a></h5>

<pre>
5215 5216 5217 5218 5219 5220 5221 5222 5223 5224 5225 5226 5227 5228 5229 5230 5231 5232 5233 5234
...
&lt;devices&gt;
  &lt;interface type='bridge'&gt;
    <b>&lt;vlan&gt;</b>
      <b>&lt;tag id='42'/&gt;</b>
    <b>&lt;/vlan&gt;</b>
    &lt;source bridge='ovsbr0'/&gt;
    &lt;virtualport type='openvswitch'&gt;
      &lt;parameters interfaceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/&gt;
    &lt;/virtualport&gt;
  &lt;/interface&gt;
  &lt;interface type='bridge'&gt;
    <b>&lt;vlan trunk='yes'&gt;</b>
      <b>&lt;tag id='42'/&gt;</b>
      <b>&lt;tag id='123' nativeMode='untagged'/&gt;</b>
    <b>&lt;/vlan&gt;</b>
    ...
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5235 5236 5237

    <p>
      If (and only if) the network connection used by the guest
5238
      supports VLAN tagging transparent to the guest, an
5239
      optional <code>&lt;vlan&gt;</code> element can specify one or
5240 5241 5242 5243 5244 5245 5246 5247 5248
      more VLAN tags to apply to the guest's network
      traffic <span class="since">Since 0.10.0</span>. Network
      connections that support guest-transparent VLAN tagging include
      1) type='bridge' interfaces connected to an Open vSwitch bridge
      <span class="since">Since 0.10.0</span>, 2) SRIOV Virtual
      Functions (VF) used via type='hostdev' (direct device
      assignment) <span class="since">Since 0.10.0</span>, and 3)
      SRIOV VFs used via type='direct' with mode='passthrough'
      (macvtap "passthru" mode) <span class="since">Since
5249
      1.3.5</span>. All other connection types, including standard
5250 5251 5252
      linux bridges and libvirt's own virtual networks, <b>do not</b>
      support it. 802.1Qbh (vn-link) and 802.1Qbg (VEPA) switches
      provide their own way (outside of libvirt) to tag guest traffic
5253 5254 5255 5256 5257 5258 5259 5260 5261
      onto a specific VLAN. Each tag is given in a
      separate <code>&lt;tag&gt;</code> subelement
      of <code>&lt;vlan&gt;</code> (for example: <code>&lt;tag
      id='42'/&gt;</code>). For VLAN trunking of multiple tags (which
      is supported only on Open vSwitch connections),
      multiple <code>&lt;tag&gt;</code> subelements can be specified,
      which implies that the user wants to do VLAN trunking on the
      interface for all the specified tags. In the case that VLAN
      trunking of a single tag is desired, the optional
5262
      attribute <code>trunk='yes'</code> can be added to the toplevel
5263 5264
      <code>&lt;vlan&gt;</code> element to differentiate trunking of a
      single tag from normal tagging.
5265
    </p>
5266
    <p>
5267 5268 5269 5270 5271 5272 5273 5274 5275 5276 5277
      For network connections using Open vSwitch it is also possible
      to configure 'native-tagged' and 'native-untagged' VLAN modes
      <span class="since">Since 1.1.0.</span> This is done with the
      optional <code>nativeMode</code> attribute on
      the <code>&lt;tag&gt;</code> subelement: <code>nativeMode</code>
      may be set to 'tagged' or 'untagged'. The <code>id</code>
      attribute of the <code>&lt;tag&gt;</code> subelement
      containing <code>nativeMode</code> sets which VLAN is considered
      to be the "native" VLAN for this interface, and
      the <code>nativeMode</code> attribute determines whether or not
      traffic for that VLAN will be tagged.
5278 5279
    </p>

5280
    <h5><a name="elementLink">Modifying virtual link state</a></h5>
5281
<pre>
5282 5283 5284 5285 5286 5287 5288 5289 5290
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet0'/&gt;
    <b>&lt;link state='down'/&gt;</b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5291 5292 5293 5294 5295 5296 5297 5298 5299 5300

    <p>
      This element provides means of setting state of the virtual network link.
      Possible values for attribute <code>state</code> are <code>up</code> and
      <code>down</code>. If <code>down</code> is specified as the value, the interface
      behaves as if it had the network cable disconnected. Default behavior if this
      element is unspecified is to have the link state <code>up</code>.
      <span class="since">Since 0.9.5</span>
    </p>

5301 5302 5303 5304 5305 5306 5307 5308 5309 5310 5311 5312 5313 5314 5315 5316 5317 5318 5319
    <h5><a name="mtu">MTU configuration</a></h5>
<pre>
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet0'/&gt;
    <b>&lt;mtu size='1500'/&gt;</b>
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>

    <p>
      This element provides means of setting MTU of the virtual network link.
      Currently there is just one attribute <code>size</code> which accepts a
      non-negative integer which specifies the MTU size for the interface.
      <span class="since">Since 3.1.0</span>
    </p>

5320 5321
    <h5><a name="ipconfig">IP configuration</a></h5>
<pre>
5322 5323 5324 5325 5326 5327 5328 5329 5330 5331
...
&lt;devices&gt;
  &lt;interface type='network'&gt;
    &lt;source network='default'/&gt;
    &lt;target dev='vnet0'/&gt;
    <b>&lt;ip address='192.168.122.5' prefix='24'/&gt;</b>
    <b>&lt;ip address='192.168.122.5' prefix='24' peer='10.0.0.10'/&gt;</b>
    <b>&lt;route family='ipv4' address='192.168.122.0' prefix='24' gateway='192.168.122.1'/&gt;</b>
    <b>&lt;route family='ipv4' address='192.168.122.8' gateway='192.168.122.1'/&gt;</b>
  &lt;/interface&gt;
5332
  ...
5333 5334 5335 5336 5337 5338 5339 5340 5341 5342 5343
  &lt;hostdev mode='capabilities' type='net'&gt;
    &lt;source&gt;
      &lt;interface&gt;eth0&lt;/interface&gt;
    &lt;/source&gt;
    <b>&lt;ip address='192.168.122.6' prefix='24'/&gt;</b>
    <b>&lt;route family='ipv4' address='192.168.122.0' prefix='24' gateway='192.168.122.1'/&gt;</b>
    <b>&lt;route family='ipv4' address='192.168.122.8' gateway='192.168.122.1'/&gt;</b>
  &lt;/hostdev&gt;

&lt;/devices&gt;
...
5344 5345 5346
</pre>

    <p>
5347 5348 5349 5350 5351 5352 5353 5354 5355 5356 5357 5358 5359 5360 5361
      <span class="since">Since 1.2.12</span> network devices and
      hostdev devices with network capabilities can optionally be provided
      one or more IP addresses to set on the network device in the
      guest. Note that some hypervisors or network device types will
      simply ignore them or only use the first one.
      The <code>family</code> attribute can be set to
      either <code>ipv4</code> or <code>ipv6</code>, and the
      <code>address</code> attribute contains the IP address. The
      optional <code>prefix</code> is the number of 1 bits in the
      netmask, and will be automatically set if not specified - for
      IPv4 the default prefix is determined according to the network
      "class" (A, B, or C - see RFC870), and for IPv6 the default
      prefix is 64. The optional <code>peer</code> attribute holds the
      IP address of the other end of a point-to-point network
      device <span class="since">(since 2.1.0)</span>.
5362 5363
    </p>

5364
    <p>
5365 5366 5367 5368 5369 5370
    <span class="since">Since 1.2.12</span> route elements can also be
    added to define IP routes to add in the guest.  The attributes of
    this element are described in the documentation for
    the <code>route</code> element
    in <a href="formatnetwork.html#elementsStaticroute">network
    definitions</a>.  This is used by the LXC driver.
5371 5372
    </p>

5373
<pre>
5374 5375 5376 5377 5378 5379 5380 5381
...
&lt;devices&gt;
  &lt;interface type='ethernet'&gt;
    <b>&lt;source/&gt;</b>
      <b>&lt;ip address='192.168.123.1' prefix='24'/&gt;</b>
      <b>&lt;ip address='10.0.0.10' prefix='24' peer='192.168.122.5'/&gt;</b>
      <b>&lt;route family='ipv4' address='192.168.42.0' prefix='24' gateway='192.168.123.4'/&gt;</b>
    <b>&lt;source/&gt;</b>
5382
    ...
5383
  &lt;/interface&gt;
5384
  ...
5385 5386
&lt;/devices&gt;
...
5387 5388 5389 5390 5391 5392 5393 5394 5395 5396 5397 5398
</pre>

    <p>
      <span class="since">Since 2.1.0</span> network devices of type
      "ethernet" can optionally be provided one or more IP addresses
      and one or more routes to set on the <b>host</b> side of the
      network device. These are configured as subelements of
      the <code>&lt;source&gt;</code> element of the interface, and
      have the same attributes as the similarly named elements used to
      configure the guest side of the interface (described above).
    </p>

M
Michele Paolino 已提交
5399 5400 5401 5402 5403 5404 5405 5406 5407 5408
    <h5><a name="elementVhostuser">vhost-user interface</a></h5>

    <p>
    <span class="since">Since 1.2.7</span> the vhost-user enables the
    communication between a QEMU virtual machine and other userspace process
    using the Virtio transport protocol.  A char dev (e.g. Unix socket) is used
    for the control plane, while the data plane is based on shared memory.
    </p>

<pre>
5409 5410 5411 5412 5413 5414 5415 5416 5417 5418 5419 5420 5421 5422 5423
...
&lt;devices&gt;
  &lt;interface type='vhostuser'&gt;
    &lt;mac address='52:54:00:3b:83:1a'/&gt;
    &lt;source type='unix' path='/tmp/vhost1.sock' mode='server'/&gt;
    &lt;model type='virtio'/&gt;
  &lt;/interface&gt;
  &lt;interface type='vhostuser'&gt;
    &lt;mac address='52:54:00:3b:83:1b'/&gt;
    &lt;source type='unix' path='/tmp/vhost2.sock' mode='client'/&gt;
    &lt;model type='virtio'/&gt;
    &lt;driver queues='5'/&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
M
Michele Paolino 已提交
5424 5425 5426 5427 5428 5429 5430 5431 5432 5433 5434 5435

    <p>
      The <code>&lt;source&gt;</code> element has to be specified
      along with the type of char device.
      Currently, only type='unix' is supported, where the path (the
      directory path of the socket) and mode attributes are required.
      Both <code>mode='server'</code> and <code>mode='client'</code>
      are supported.
      vhost-user requires the virtio model type, thus the
      <code>&lt;model&gt;</code> element is mandatory.
    </p>

5436 5437 5438 5439 5440 5441 5442 5443 5444 5445 5446 5447
    <h5><a name="elementNwfilter">Traffic filtering with NWFilter</a></h5>

    <p>
    <span class="since">Since 0.8.0</span> an <code>nwfilter</code> profile
    can be assigned to a domain interface, which allows configuring
    traffic filter rules for the virtual machine.

    See the <a href="formatnwfilter.html">nwfilter</a> documentation for more
    complete details.
    </p>

<pre>
5448 5449 5450 5451 5452 5453 5454 5455 5456 5457 5458 5459
...
&lt;devices&gt;
  &lt;interface ...&gt;
    ...
    &lt;filterref filter='clean-traffic'/&gt;
  &lt;/interface&gt;
  &lt;interface ...&gt;
    ...
    &lt;filterref filter='myfilter'&gt;
      &lt;parameter name='IP' value='104.207.129.11'/&gt;
      &lt;parameter name='IP6_ADDR' value='2001:19f0:300:2102::'/&gt;
      &lt;parameter name='IP6_MASK' value='64'/&gt;
5460
      ...
5461 5462 5463 5464
    &lt;/filterref&gt;
  &lt;/interface&gt;
&lt;/devices&gt;
...</pre>
5465 5466 5467 5468 5469 5470 5471 5472 5473 5474 5475

    <p>
      The <code>filter</code> attribute specifies the name of the nwfilter
      to use. Optional <code>&lt;parameter&gt;</code> elements may be
      specified for passing additional info to the nwfilter via the
      <code>name</code> and <code>value</code> attributes. See
      the <a href="formatnwfilter.html#nwfconceptsvars">nwfilter</a>
      docs for info on parameters.
    </p>


D
Daniel P. Berrange 已提交
5476 5477 5478
    <h4><a name="elementsInput">Input devices</a></h4>

    <p>
E
Eric Blake 已提交
5479 5480 5481 5482
      Input devices allow interaction with the graphical framebuffer
      in the guest virtual machine. When enabling the framebuffer, an
      input device is automatically provided. It may be possible to
      add additional devices explicitly, for example,
D
Daniel P. Berrange 已提交
5483 5484 5485
      to provide a graphics tablet for absolute cursor movement.
    </p>

5486
<pre>
5487 5488 5489 5490 5491 5492 5493 5494 5495 5496 5497 5498
...
&lt;devices&gt;
  &lt;input type='mouse' bus='usb'/&gt;
  &lt;input type='keyboard' bus='usb'/&gt;
  &lt;input type='mouse' bus='virtio'/&gt;
  &lt;input type='keyboard' bus='virtio'/&gt;
  &lt;input type='tablet' bus='virtio'/&gt;
  &lt;input type='passthrough' bus='virtio'&gt;
    &lt;source evdev='/dev/input/event1/&gt;
  &lt;/input&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
5499 5500 5501

    <dl>
      <dt><code>input</code></dt>
E
Eric Blake 已提交
5502
      <dd>The <code>input</code> element has one mandatory attribute,
5503 5504 5505
        the <code>type</code> whose value can be 'mouse', 'tablet',
        (<span class="since">since 1.2.2</span>) 'keyboard' or
        (<span class="since">since 1.3.0</span>) 'passthrough'.
5506 5507
        The tablet provides absolute cursor movement,
        while the mouse uses relative movement. The optional
M
Matthew Booth 已提交
5508
        <code>bus</code> attribute can be used to refine the exact device type.
5509 5510
        It takes values "xen" (paravirtualized), "ps2" and "usb" or
        (<span class="since">since 1.3.0</span>) "virtio".</dd>
D
Daniel P. Berrange 已提交
5511 5512
    </dl>

E
Eric Blake 已提交
5513 5514 5515
    <p>
      The <code>input</code> element has an optional
      sub-element <code>&lt;address&gt;</code> which can tie the
5516 5517
      device to a particular PCI
      slot, <a href="#elementsAddress">documented above</a>.
5518 5519 5520 5521

      For type <code>passthrough</code>, the mandatory sub-element <code>source</code>
      must have an <code>evdev</code> attribute containing the absolute path to the
      event device passed through to guests. (KVM only)
E
Eric Blake 已提交
5522
    </p>
D
Daniel P. Berrange 已提交
5523

M
Marc-André Lureau 已提交
5524 5525 5526 5527 5528 5529 5530 5531 5532
    <h4><a name="elementsHub">Hub devices</a></h4>

    <p>
      A hub is a device that expands a single port into several so
      that there are more ports available to connect devices to a host
      system.
    </p>

<pre>
5533 5534 5535 5536 5537
...
&lt;devices&gt;
  &lt;hub type='usb'/&gt;
&lt;/devices&gt;
...</pre>
M
Marc-André Lureau 已提交
5538 5539 5540 5541 5542 5543 5544 5545 5546

    <dl>
      <dt><code>hub</code></dt>
      <dd>The <code>hub</code> element has one mandatory attribute,
        the <code>type</code> whose value can only be 'usb'.</dd>
    </dl>

    <p>
      The <code>hub</code> element has an optional
5547 5548 5549 5550
      sub-element <code>&lt;address&gt;</code>
      with <code>type='usb'</code>which can tie the device to a
      particular controller, <a href="#elementsAddress">documented
      above</a>.
M
Marc-André Lureau 已提交
5551 5552
    </p>

D
Daniel P. Berrange 已提交
5553 5554 5555 5556 5557 5558 5559 5560 5561
    <h4><a name="elementsGraphics">Graphical framebuffers</a></h4>

    <p>
      A graphics device allows for graphical interaction with the
      guest OS. A guest will typically have either a framebuffer
      or a text console configured to allow interaction with the
      admin.
    </p>

5562
<pre>
5563 5564 5565 5566 5567 5568 5569 5570 5571 5572 5573 5574 5575
...
&lt;devices&gt;
  &lt;graphics type='sdl' display=':0.0'/&gt;
  &lt;graphics type='vnc' port='5904' sharePolicy='allow-exclusive'&gt;
    &lt;listen type='address' address='1.2.3.4'/&gt;
  &lt;/graphics&gt;
  &lt;graphics type='rdp' autoport='yes' multiUser='yes' /&gt;
  &lt;graphics type='desktop' fullscreen='yes'/&gt;
  &lt;graphics type='spice'&gt;
    &lt;listen type='network' network='rednet'/&gt;
  &lt;/graphics&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
5576 5577 5578

    <dl>
      <dt><code>graphics</code></dt>
5579 5580 5581 5582 5583 5584
      <dd>
        <p>
          The <code>graphics</code> element has a mandatory <code>type</code>
          attribute which takes the value <code>sdl</code>, <code>vnc</code>,
          <code>spice</code>, <code>rdp</code> or <code>desktop</code>:
        </p>
5585
        <dl>
5586
          <dt><code>sdl</code></dt>
5587
          <dd>
5588 5589 5590 5591 5592 5593 5594
            <p>
              This displays a window on the host desktop, it can take 3 optional
              arguments: a <code>display</code> attribute for the display to use,
              an <code>xauth</code> attribute for the authentication identifier,
              and an optional <code>fullscreen</code> attribute accepting values
              <code>yes</code> or <code>no</code>.
            </p>
5595
          </dd>
5596
          <dt><code>vnc</code></dt>
5597
          <dd>
5598 5599 5600 5601 5602
            <p>
              Starts a VNC server. The <code>port</code> attribute specifies
              the TCP port number (with -1 as legacy syntax indicating that it
              should be auto-allocated). The <code>autoport</code> attribute is
              the new preferred syntax for indicating auto-allocation of the TCP
5603
              port to use. The <code>passwd</code> attribute provides a VNC
5604 5605 5606 5607 5608 5609 5610
              password in clear text. If the <code>passwd</code> attribute is
              set to an empty string, then VNC access is disabled. The
              <code>keymap</code> attribute specifies the keymap to use. It is
              possible to set a limit on the validity of the password by giving
              an timestamp <code>passwdValidTo='2010-04-09T15:51:00'</code>
              assumed to be in UTC. The <code>connected</code> attribute allows
              control of connected client during password changes. VNC accepts
5611 5612 5613 5614 5615 5616 5617 5618 5619 5620 5621 5622 5623 5624 5625 5626 5627 5628 5629 5630 5631 5632 5633 5634 5635
              <code>keep</code> value only <span class="since">since 0.9.3</span>.
              NB, this may not be supported by all hypervisors.
            </p>
            <p>
              The optional <code>sharePolicy</code> attribute specifies vnc
              server display sharing policy. <code>allow-exclusive</code> allows
              clients to ask for exclusive access by dropping other connections.
              Connecting multiple clients in parallel requires all clients asking
              for a shared session (vncviewer: -Shared switch). This is
              the default value. <code>force-shared</code> disables exclusive
              client access, every connection has to specify -Shared switch for
              vncviewer. <code>ignore</code> welcomes every connection
              unconditionally <span class="since">since 1.0.6</span>.
            </p>
            <p>
              Rather than using listen/port, QEMU supports a <code>socket</code>
              attribute for listening on a unix domain socket path
              <span class="since">Since 0.8.8</span>.
            </p>
            <p>
              For VNC WebSocket functionality, <code>websocket</code> attribute
              may be used to specify port to listen on (with -1 meaning
              auto-allocation and <code>autoport</code> having no effect due to
              security reasons) <span class="since">Since 1.0.6</span>.
            </p>
5636
          </dd>
5637
          <dt><code>spice</code> <span class="since">Since 0.8.6</span></dt>
5638
          <dd>
E
Eric Blake 已提交
5639
            <p>
5640 5641 5642 5643 5644
              Starts a SPICE server. The <code>port</code> attribute specifies
              the TCP port number (with -1 as legacy syntax indicating that it
              should be auto-allocated), while <code>tlsPort</code> gives
              an alternative secure port number. The <code>autoport</code>
              attribute is the new preferred syntax for indicating
5645
              auto-allocation of needed port numbers. The <code>passwd</code>
5646 5647 5648 5649 5650 5651 5652
              attribute provides a SPICE password in clear text. If the
              <code>passwd</code> attribute is set to an empty string, then
              SPICE access is disabled. The <code>keymap</code> attribute
              specifies the keymap to use. It is possible to set a limit on
              the validity of the password by giving an timestamp
              <code>passwdValidTo='2010-04-09T15:51:00'</code> assumed to be
              in UTC.
5653 5654 5655 5656 5657 5658 5659
            </p>
            <p>
              The <code>connected</code> attribute allows control of connected
              client during password changes. SPICE accepts <code>keep</code> to
              keep client connected, <code>disconnect</code> to disconnect client
              and <code>fail</code> to fail changing password . NB, this may not
              be supported by all hypervisors.
5660
              <span class="since">Since 0.9.3</span>
5661 5662
            </p>
            <p>
5663 5664
              The <code>defaultMode</code> attribute sets the default channel
              security policy, valid values are <code>secure</code>,
5665 5666 5667 5668
              <code>insecure</code> and the default <code>any</code> (which is
              secure if possible, but falls back to insecure rather than erroring
              out if no secure path is available).
              <span class="since">Since 0.9.12</span>
E
Eric Blake 已提交
5669 5670
            </p>
            <p>
5671 5672 5673 5674 5675 5676 5677 5678
              When SPICE has both a normal and TLS secured TCP port configured,
              it can be desirable to restrict what channels can be run on each
              port. This is achieved by adding one or more <code>&lt;channel&gt;
              </code> elements inside the main <code>&lt;graphics&gt;</code>
              element and setting the <code>mode</code> attribute to either
              <code>secure</code> or <code>insecure</code>. Setting the mode
              attribute overrides the default value as set by
              the <code>defaultMode</code> attribute. (Note that specifying
5679
              <code>any</code> as mode discards the entry as the channel would
5680 5681 5682
              inherit the default mode anyways.) Valid channel names include
              <code>main</code>, <code>display</code>, <code>inputs</code>,
              <code>cursor</code>, <code>playback</code>, <code>record</code>
5683
              (all <span class="since"> since 0.8.6</span>);
5684 5685
              <code>smartcard</code> (<span class="since">since 0.8.8</span>);
              and <code>usbredir</code> (<span class="since">since 0.9.12</span>).
E
Eric Blake 已提交
5686 5687
            </p>
            <pre>
5688 5689 5690 5691 5692 5693 5694 5695
&lt;graphics type='spice' port='-1' tlsPort='-1' autoport='yes'&gt;
  &lt;channel name='main' mode='secure'/&gt;
  &lt;channel name='record' mode='insecure'/&gt;
  &lt;image compression='auto_glz'/&gt;
  &lt;streaming mode='filter'/&gt;
  &lt;clipboard copypaste='no'/&gt;
  &lt;mouse mode='client'/&gt;
  &lt;filetransfer enable='no'/&gt;
5696
  &lt;gl enable='yes' rendernode='/dev/dri/by-path/pci-0000:00:02.0-render'/&gt;
5697
&lt;/graphics&gt;</pre>
5698
            <p>
5699 5700 5701 5702 5703 5704 5705 5706 5707 5708 5709 5710
              Spice supports variable compression settings for audio, images and
              streaming. These settings are accessible via the <code>compression
              </code> attribute in all following elements: <code>image</code> to
              set image compression (accepts <code>auto_glz</code>,
              <code>auto_lz</code>, <code>quic</code>, <code>glz</code>,
              <code>lz</code>, <code>off</code>), <code>jpeg</code> for JPEG
              compression for images over wan (accepts <code>auto</code>,
              <code>never</code>, <code>always</code>), <code>zlib</code> for
              configuring wan image compression (accepts <code>auto</code>,
              <code>never</code>, <code>always</code>)  and <code>playback</code>
              for enabling audio stream compression (accepts <code>on</code> or
              <code>off</code>). <span class="since">Since 0.9.1</span>
5711
            </p>
5712
            <p>
5713 5714 5715 5716
              Streaming mode is set by the <code>streaming</code> element,
              settings its <code>mode</code> attribute to one of
              <code>filter</code>, <code>all</code> or <code>off</code>.
              <span class="since">Since 0.9.2</span>
5717
            </p>
5718
            <p>
5719 5720 5721 5722
              Copy &amp; Paste functionality (via Spice agent) is set by the
              <code>clipboard</code> element. It is enabled by default, and can
              be disabled by setting the <code>copypaste</code> property to
              <code>no</code>. <span class="since">Since 0.9.3</span>
5723
            </p>
P
Peng Zhou 已提交
5724
            <p>
5725 5726 5727 5728
              Mouse mode is set by the <code>mouse</code> element, setting its
              <code>mode</code> attribute to one of <code>server</code> or
              <code>client</code>. If no mode is specified, the qemu default will
              be used (client mode). <span class="since">Since 0.9.11</span>
P
Peng Zhou 已提交
5729
            </p>
5730 5731
            <p>
              File transfer functionality (via Spice agent) is set using the
5732 5733 5734
              <code>filetransfer</code> element. It is enabled by default, and
              can be disabled by setting the <code>enable</code> property to
              <code>no</code>. <span class="since">Since 1.2.2</span>
5735
            </p>
5736
            <p>
5737 5738 5739
              Spice may provide accelerated server-side rendering with OpenGL.
              You can enable or disable OpenGL support explicitly with
              the <code>gl</code> element, by setting the <code>enable</code>
5740
              property. (QEMU only, <span class="since">since 1.3.3</span>).
5741
            </p>
5742 5743 5744 5745 5746
            <p>
              By default, QEMU will pick the first available GPU DRM render node.
              You may specify a DRM render node path to use instead. (QEMU only,
              <span class="since">since 3.1.0</span>).
            </p>
5747
          </dd>
5748
          <dt><code>rdp</code></dt>
5749
          <dd>
5750 5751 5752 5753 5754 5755 5756 5757 5758 5759 5760 5761
            <p>
              Starts a RDP server. The <code>port</code> attribute specifies the
              TCP port number (with -1 as legacy syntax indicating that it should
              be auto-allocated). The <code>autoport</code> attribute is the new
              preferred syntax for indicating auto-allocation of the TCP port to
              use. The <code>replaceUser</code> attribute is a boolean deciding
              whether multiple simultaneous connections to the VM are permitted.
              The <code>multiUser</code> attribute is a boolean deciding whether
              the existing connection must be dropped and a new connection must
              be established by the VRDP server, when a new client connects in
              single connection mode.
            </p>
5762
          </dd>
5763
          <dt><code>desktop</code></dt>
5764
          <dd>
5765 5766 5767 5768 5769 5770 5771
            <p>
              This value is reserved for VirtualBox domains for the moment. It
              displays a window on the host desktop, similarly to "sdl", but
              using the VirtualBox viewer. Just like "sdl", it accepts
              the optional attributes <code>display</code> and
              <code>fullscreen</code>.
            </p>
5772 5773 5774 5775 5776
          </dd>
        </dl>
      </dd>
    </dl>

5777
    <p>
5778 5779 5780 5781 5782 5783
      Graphics device uses a <code>&lt;listen&gt;</code> to set up where
      the device should listen for clients. It has a mandatory attribute
      <code>type</code> which specifies the listen type. Only <code>vnc</code>,
      <code>spice</code> and <code>rdp</code> supports <code>&lt;listen&gt;
      </code> element. <span class="since">Since 0.9.4</span>.
      Available types are:
5784 5785 5786
    </p>
    <dl>
      <dt><code>address</code></dt>
5787 5788 5789 5790 5791 5792 5793
      <dd>
        <p>
          Tells a graphics device to use an address specified in the
          <code>address</code> attribute, which will contain either an IP address
          or hostname (which will be resolved to an IP address via a DNS query)
          to listen on.
        </p>
5794 5795 5796 5797 5798 5799 5800 5801 5802
        <p>
          It is possible to omit the <code>address</code> attribute in order to
          use an address from config files <span class="since">Since 1.3.5</span>.
        </p>
        <p>
          The <code>address</code> attribute is duplicated as <code>listen</code>
          attribute in <code>graphics</code> element for backward compatibility.
          If both are provided they must be equal.
        </p>
5803 5804
      </dd>
      <dt><code>network</code></dt>
5805 5806 5807 5808 5809 5810 5811 5812 5813 5814 5815 5816 5817 5818 5819
      <dd>
        <p>
          This is used to specify an existing network in the <code>network</code>
          attribute from libvirt's list of configured networks. The named network
          configuration will be examined to determine an appropriate listen
          address and the address will be stored in live XML in <code>address
          </code> attribute. For example, if the network has an IPv4 address in
          its configuration (e.g. if it has a forward type of <code>route</code>,
          <code>nat</code>, or no forward type (isolated)), the first IPv4
          address listed in the network's configuration will be used.
          If the network is describing a host bridge, the first IPv4 address
          associated with that bridge device will be used, and if the network is
          describing one of the 'direct' (macvtap) modes, the first IPv4 address
          of the first forward dev will be used.
        </p>
5820
      </dd>
5821
      <dt><code>socket</code> <span class="since">since 2.0.0 (QEMU only)</span></dt>
5822 5823 5824 5825 5826
      <dd>
        <p>
          This listen type tells a graphics server to listen on unix socket.
          Attribute <code>socket</code> contains a path to unix socket. If this
          attribute is omitted libvirt will generate this path for you.
5827
          Supported by graphics type <code>vnc</code> and <code>spice</code>.
5828 5829 5830 5831 5832 5833 5834
        </p>
        <p>
          For <code>vnc</code> graphics be backward compatible
          the <code>socket</code> attribute of first <code>listen</code> element
          is duplicated as <code>socket</code> attribute in <code>graphics</code>
          element. If <code>graphics</code> element contains a <code>socket</code>
          attribute all <code>listen</code> elements are ignored.
5835 5836
        </p>
      </dd>
5837
      <dt><code>none</code> <span class="since">since 2.0.0 (QEMU only)</span></dt>
P
Pavel Hrdina 已提交
5838 5839 5840 5841 5842 5843 5844
      <dd>
        <p>
          This listen type doesn't have any other attribute. Libvirt supports
          passing a file descriptor through our APIs virDomainOpenGraphics() and
          virDomainOpenGraphicsFD(). No other listen types are allowed if this
          one is used and the graphics device doesn't listen anywhere. You need
          to use one of the two APIs to pass a FD to QEMU in order to connect to
5845 5846
          this graphics device. Supported by graphics type <code>vnc</code> and
          <code>spice</code>.
P
Pavel Hrdina 已提交
5847 5848
        </p>
      </dd>
5849 5850
    </dl>

5851 5852 5853 5854 5855
    <h4><a name="elementsVideo">Video devices</a></h4>
    <p>
      A video device.
    </p>

5856
<pre>
5857 5858 5859 5860 5861 5862 5863 5864 5865
...
&lt;devices&gt;
  &lt;video&gt;
    &lt;model type='vga' vram='16384' heads='1'&gt;
      &lt;acceleration accel3d='yes' accel2d='yes'/&gt;
    &lt;/model&gt;
  &lt;/video&gt;
&lt;/devices&gt;
...</pre>
5866 5867 5868

    <dl>
      <dt><code>video</code></dt>
5869
      <dd>
5870 5871 5872 5873 5874 5875 5876 5877 5878 5879 5880 5881 5882 5883
        <p>
          The <code>video</code> element is the container for describing
          video devices. For backwards compatibility, if no <code>video</code>
          is set but there is a <code>graphics</code> in domain xml, then
          libvirt will add a default <code>video</code> according to the guest
          type.
        </p>
        <p>
          For a guest of type "kvm", the default <code>video</code> is:
          <code>type</code> with value "cirrus", <code>vram</code> with value
          "16384" and <code>heads</code> with value "1". By default, the first
          video device in domain xml is the primary one, but the optional
          attribute <code>primary</code> (<span class="since">since 1.0.2</span>)
          with value 'yes' can be used to mark the primary in cases of multiple
5884 5885
          video device. The non-primary must be type of "qxl" or
          (<span class="since">since 2.4.0</span>) "virtio".
5886
        </p>
5887
      </dd>
5888

5889 5890
      <dt><code>model</code></dt>
      <dd>
5891 5892 5893
        <p>
          The <code>model</code> element has a mandatory <code>type</code>
          attribute which takes the value "vga", "cirrus", "vmvga", "xen",
F
Fabian Freyer 已提交
5894
          "vbox", "qxl" (<span class="since">since 0.8.6</span>),
M
Marc-André Lureau 已提交
5895
          "virtio" (<span class="since">since 1.3.0</span>)
F
Fabian Freyer 已提交
5896
          or "gop" (<span class="since">since 3.2.0</span>)
M
Marc-André Lureau 已提交
5897
          depending on the hypervisor features available.
5898 5899 5900 5901
        </p>
        <p>
          You can provide the amount of video memory in kibibytes (blocks of
          1024 bytes) using <code>vram</code>. This is supported only for guest
5902
          type of "libxl", "vz", "qemu", "vbox", "vmx" and "xen". If no
5903 5904 5905 5906 5907
          value is provided the default is used. If the size is not a power of
          two it will be rounded to closest one.
        </p>
        <p>
          The number of screen can be set using <code>heads</code>. This is
5908
          supported only for guests type of "vz", "kvm", "vbox" and "vmx".
5909 5910
        </p>
        <p>
5911 5912 5913
          For guest type of "kvm" or "qemu" and model type "qxl" there are
          optional attributes. Attribute <code>ram</code> (<span class="since">
          since 1.0.2</span>) specifies the size of the primary bar, while the
5914
          attribute <code>vram</code> specifies the secondary bar size.
5915 5916 5917 5918 5919
          If <code>ram</code> or <code>vram</code> are not supplied a default
          value is used. The <code>ram</code> should also be rounded to power of
          two as <code>vram</code>. There is also optional attribute
          <code>vgamem</code> (<span class="since">since 1.2.11</span>) to set
          the size of VGA framebuffer for fallback mode of QXL device.
5920
          Attribute <code>vram64</code> (<span class="since">since 1.3.3</span>)
5921
          extends secondary bar and makes it addressable as 64bit memory.
5922
        </p>
5923 5924 5925 5926
      </dd>

      <dt><code>acceleration</code></dt>
      <dd>
5927 5928 5929 5930 5931 5932 5933 5934 5935 5936 5937
        Configure if video acceleration should be enabled.
        <dl>
        <dt><code>accel2d</code></dt>
        <dd>Enable 2D acceleration (for vbox driver only,
        <span class="since">since 0.7.1</span>)</dd>

        <dt><code>accel3d</code></dt>
        <dd>Enable 3D acceleration (for vbox driver
        <span class="since">since 0.7.1</span>, qemu driver
        <span class="since">since 1.3.0</span>)</dd>
        </dl>
5938
      </dd>
E
Eric Blake 已提交
5939 5940 5941 5942 5943 5944

      <dt><code>address</code></dt>
      <dd>
        The optional <code>address</code> sub-element can be used to
        tie the video device to a particular PCI slot.
      </dd>
D
Daniel P. Berrange 已提交
5945 5946
    </dl>

5947
    <h4><a name="elementsConsole">Consoles, serial, parallel &amp; channel devices</a></h4>
D
Daniel P. Berrange 已提交
5948 5949 5950

    <p>
      A character device provides a way to interact with the virtual machine.
5951 5952
      Paravirtualized consoles, serial ports, parallel ports and channels are
      all classed as character devices and so represented using the same syntax.
D
Daniel P. Berrange 已提交
5953 5954
    </p>

5955
<pre>
5956 5957 5958 5959 5960 5961 5962 5963 5964 5965 5966 5967 5968 5969 5970 5971 5972 5973 5974 5975 5976 5977 5978 5979 5980 5981
...
&lt;devices&gt;
  &lt;parallel type='pty'&gt;
    &lt;source path='/dev/pts/2'/&gt;
    &lt;target port='0'/&gt;
  &lt;/parallel&gt;
  &lt;serial type='pty'&gt;
    &lt;source path='/dev/pts/3'/&gt;
    &lt;target port='0'/&gt;
  &lt;/serial&gt;
  &lt;serial type='file'&gt;
    &lt;source path='/tmp/file' append='on'&gt;
      &lt;seclabel model='dac' relabel='no'/&gt;
    &lt;/source&gt;
    &lt;target port='0'/&gt;
  &lt;/serial&gt;
  &lt;console type='pty'&gt;
    &lt;source path='/dev/pts/4'/&gt;
    &lt;target port='0'/&gt;
  &lt;/console&gt;
  &lt;channel type='unix'&gt;
    &lt;source mode='bind' path='/tmp/guestfwd'/&gt;
    &lt;target type='guestfwd' address='10.0.2.1' port='4600'/&gt;
  &lt;/channel&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
5982

5983 5984 5985 5986 5987
    <p>
      In each of these directives, the top-level element name (parallel, serial,
      console, channel) describes how the device is presented to the guest. The
      guest interface is configured by the <code>target</code> element.
    </p>
D
Daniel P. Berrange 已提交
5988

5989 5990 5991 5992 5993 5994
    <p>
      The interface presented to the host is given in the <code>type</code>
      attribute of the top-level element. The host interface is
      configured by the <code>source</code> element.
    </p>

5995 5996 5997 5998 5999 6000 6001 6002
    <p>
      The <code>source</code> element may contain an optional
      <code>seclabel</code> to override the way that labelling
      is done on the socket path.  If this element is not present,
      the <a href="#seclabel">security label is inherited from
        the per-domain setting</a>.
    </p>

6003 6004 6005 6006 6007 6008 6009 6010
    <p>
      If the interface <code>type</code> presented to the host is "file",
      then the <code>source</code> element may contain an optional attribute
      <code>append</code> that specifies whether or not the information in
      the file should be preserved on domain restart. Allowed values are
      "on" and "off" (default). <span class="since">Since 1.3.1</span>.
    </p>

6011
    <p>
B
Boris Fiuczynski 已提交
6012
      Regardless of the <code>type</code>, character devices can
6013 6014
      have an optional log file associated with them. This is
      expressed via a <code>log</code> sub-element, with a
B
Boris Fiuczynski 已提交
6015 6016 6017
      <code>file</code> attribute. There can also be an <code>append</code>
      attribute which takes the same values described above.
      <span class="since">Since 1.3.3</span>.
6018 6019 6020
    </p>

    <pre>
6021 6022 6023
...
&lt;log file="/var/log/libvirt/qemu/guestname-serial0.log" append="off"/&gt;
...</pre>
6024

E
Eric Blake 已提交
6025 6026 6027 6028 6029 6030 6031 6032
    <p>
      Each character device element has an optional
      sub-element <code>&lt;address&gt;</code> which can tie the
      device to a
      particular <a href="#elementsControllers">controller</a> or PCI
      slot.
    </p>

6033 6034 6035 6036 6037 6038 6039 6040 6041
    <h5><a name="elementsCharGuestInterface">Guest interface</a></h5>

    <p>
      A character device presents itself to the guest as one of the following
      types.
    </p>

    <h6><a name="elementCharParallel">Parallel port</a></h6>

6042
<pre>
6043 6044 6045 6046 6047 6048 6049 6050
...
&lt;devices&gt;
  &lt;parallel type='pty'&gt;
    &lt;source path='/dev/pts/2'/&gt;
    &lt;target port='0'/&gt;
  &lt;/parallel&gt;
&lt;/devices&gt;
...</pre>
6051 6052 6053

    <p>
      <code>target</code> can have a <code>port</code> attribute, which
6054
      specifies the port number. Ports are numbered starting from 0. There are
6055 6056 6057 6058 6059
      usually 0, 1 or 2 parallel ports.
    </p>

    <h6><a name="elementCharSerial">Serial port</a></h6>

6060
<pre>
6061 6062 6063 6064 6065 6066 6067 6068
...
&lt;devices&gt;
  &lt;serial type='pty'&gt;
    &lt;source path='/dev/pts/3'/&gt;
    &lt;target port='0'/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
6069 6070 6071

    <p>
      <code>target</code> can have a <code>port</code> attribute, which
6072
      specifies the port number. Ports are numbered starting from 0. There are
G
Guannan Ren 已提交
6073 6074
      usually 0, 1 or 2 serial ports. There is also an optional
      <code>type</code> attribute <span class="since">since 1.0.2</span>
M
Michal Privoznik 已提交
6075 6076 6077 6078 6079 6080 6081 6082 6083 6084
      which has three choices for its value, one is <code>isa-serial</code>,
      then <code>usb-serial</code> and last one is <code>pci-serial</code>.
      If <code>type</code> is missing, <code>isa-serial</code> will be used by
      default. For <code>usb-serial</code> an optional sub-element
      <code>&lt;address/&gt;</code> with <code>type='usb'</code> can tie the
      device to a particular controller, <a href="#elementsAddress">documented above</a>.
      Similarly, <code>pci-serial</code> can be used to attach the device to
      the pci bus (<span class="since">since 1.2.16</span>). Again, it has
      optional sub-element <code>&lt;address/&gt;</code> with
      <code>type='pci'</code> to select desired location on the PCI bus.
6085 6086 6087 6088 6089
    </p>

    <h6><a name="elementCharConsole">Console</a></h6>

    <p>
6090 6091 6092 6093 6094 6095 6096
      The console element is used to represent interactive consoles. Depending
      on the type of guest in use, the consoles might be paravirtualized devices,
      or they might be a clone of a serial device, according to the following
      rules:
    </p>

    <ul>
6097
      <li>If no <code>targetType</code> attribute is set, then the default
6098 6099 6100 6101 6102 6103 6104 6105 6106 6107 6108 6109 6110
        device type is according to the hypervisor's rules. The default
        type will be added when re-querying the XML fed into libvirt.
        For fully virtualized guests, the default device type will usually
        be a serial port.</li>
      <li>If the <code>targetType</code> attribute is <code>serial</code>,
        then if no <code>&lt;serial&gt;</code> element exists, the console
        element will be copied to the serial element. If a <code>&lt;serial&gt;</code>
        element does already exist, the console element will be ignored.</li>
      <li>If the <code>targetType</code> attribute is not <code>serial</code>,
        it will be treated normally.</li>
      <li>Only the first <code>console</code> element may use a <code>targetType</code>
        of <code>serial</code>. Secondary consoles must all be paravirtualized.
      </li>
B
Boris Fiuczynski 已提交
6111
      <li>On S390, the <code>console</code> element may use a
6112
        <code>targetType</code> of <code>sclp</code> or <code>sclplm</code>
B
Boris Fiuczynski 已提交
6113
        (line mode). SCLP is the native console type for S390. There's no
6114 6115 6116
        controller associated to SCLP consoles.
        <span class="since">Since 1.0.2</span>
      </li>
6117
    </ul>
C
Cole Robinson 已提交
6118 6119 6120 6121 6122 6123

    <p>
      A virtio console device is exposed in the
      guest as /dev/hvc[0-7] (for more information, see
      <a href="http://fedoraproject.org/wiki/Features/VirtioSerial">http://fedoraproject.org/wiki/Features/VirtioSerial</a>)
      <span class="since">Since 0.8.3</span>
6124 6125
    </p>

6126
<pre>
6127 6128 6129 6130 6131 6132 6133 6134 6135 6136 6137 6138 6139 6140
...
&lt;devices&gt;
  &lt;console type='pty'&gt;
    &lt;source path='/dev/pts/4'/&gt;
    &lt;target port='0'/&gt;
  &lt;/console&gt;

  &lt;!-- KVM virtio console --&gt;
  &lt;console type='pty'&gt;
    &lt;source path='/dev/pts/5'/&gt;
    &lt;target type='virtio' port='0'/&gt;
  &lt;/console&gt;
&lt;/devices&gt;
...</pre>
6141

6142
<pre>
6143 6144 6145 6146 6147 6148 6149 6150 6151
...
&lt;devices&gt;
  &lt;!-- KVM S390 sclp console --&gt;
  &lt;console type='pty'&gt;
    &lt;source path='/dev/pts/1'/&gt;
    &lt;target type='sclp' port='0'/&gt;
  &lt;/console&gt;
&lt;/devices&gt;
...</pre>
6152

6153 6154 6155 6156 6157 6158
    <p>
      If the console is presented as a serial port, the <code>target</code>
      element has the same attributes as for a serial port. There is usually
      only 1 console.
    </p>

6159 6160 6161 6162 6163 6164 6165
    <h6><a name="elementCharChannel">Channel</a></h6>

    <p>
      This represents a private communication channel between the host and the
      guest.
    </p>

6166
<pre>
6167 6168 6169 6170 6171 6172 6173 6174 6175 6176 6177 6178 6179 6180 6181 6182 6183 6184 6185 6186
...
&lt;devices&gt;
  &lt;channel type='unix'&gt;
    &lt;source mode='bind' path='/tmp/guestfwd'/&gt;
    &lt;target type='guestfwd' address='10.0.2.1' port='4600'/&gt;
  &lt;/channel&gt;

  &lt;!-- KVM virtio channel --&gt;
  &lt;channel type='pty'&gt;
    &lt;target type='virtio' name='arbitrary.virtio.serial.port.name'/&gt;
  &lt;/channel&gt;
  &lt;channel type='unix'&gt;
    &lt;source mode='bind' path='/var/lib/libvirt/qemu/f16x86_64.agent'/&gt;
    &lt;target type='virtio' name='org.qemu.guest_agent.0' state='connected'/&gt;
  &lt;/channel&gt;
  &lt;channel type='spicevmc'&gt;
    &lt;target type='virtio' name='com.redhat.spice.0'/&gt;
  &lt;/channel&gt;
&lt;/devices&gt;
...</pre>
6187 6188 6189 6190 6191 6192 6193 6194 6195 6196 6197 6198 6199 6200

    <p>
      This can be implemented in a variety of ways. The specific type of
      channel is given in the <code>type</code> attribute of the
      <code>target</code> element. Different channel types have different
      <code>target</code> attributes.
    </p>

    <dl>
      <dt><code>guestfwd</code></dt>
      <dd>TCP traffic sent by the guest to a given IP address and port is
        forwarded to the channel device on the host. The <code>target</code>
        element must have <code>address</code> and <code>port</code> attributes.
        <span class="since">Since 0.7.3</span></dd>
6201 6202 6203

      <dt><code>virtio</code></dt>
      <dd>Paravirtualized virtio channel. Channel is exposed in the guest under
E
Eric Blake 已提交
6204
        /dev/vport*, and if the optional element <code>name</code> is specified,
6205
        /dev/virtio-ports/$name (for more info, please see
E
Eric Blake 已提交
6206 6207
        <a href="http://fedoraproject.org/wiki/Features/VirtioSerial">http://fedoraproject.org/wiki/Features/VirtioSerial</a>). The
        optional element <code>address</code> can tie the channel to a
6208 6209
        particular <code>type='virtio-serial'</code>
        controller, <a href="#elementsAddress">documented above</a>.
D
Daniel P. Berrange 已提交
6210 6211 6212 6213
        With qemu, if <code>name</code> is "org.qemu.guest_agent.0",
        then libvirt can interact with a guest agent installed in the
        guest, for actions such as guest shutdown or file system quiescing.
        <span class="since">Since 0.7.7, guest agent interaction
6214
        since 0.9.10</span> Moreover, <span class="since">since 1.0.6</span>
6215 6216 6217 6218
        it is possible to have source path auto generated for virtio unix channels.
        This is very useful in case of a qemu guest agent, where users don't
        usually care about the source path since it's libvirt who talks to
        the guest agent. In case users want to utilize this feature, they should
6219 6220 6221 6222 6223 6224
        leave <code>&lt;source&gt;</code> element out. <span class="since">Since
        1.2.11</span> the active XML for a virtio channel may contain an optional
        <code>state</code> attribute that reflects whether a process in the
        guest is active on the channel. This is an output-only attribute.
        Possible values for the <code>state</code> attribute are
        <code>connected</code> and <code>disconnected</code>.
6225
      </dd>
J
Joao Martins 已提交
6226 6227 6228 6229 6230 6231 6232 6233 6234 6235
      <dt><code>xen</code></dt>
      <dd> Paravirtualized Xen channel. Channel is exposed in the guest as a
        Xen console but identified with a name. Setup and consumption of a Xen
        channel depends on software and configuration in the guest
        (for more info, please see <a href="http://xenbits.xen.org/docs/unstable/misc/channel.txt">http://xenbits.xen.org/docs/unstable/misc/channel.txt</a>).
        Channel source path semantics are the same as the virtio target type.
        The <code>state</code> attribute is not supported since Xen channels
        lack the necessary probing mechanism.
        <span class="since">Since 2.3.0</span>
      </dd>
6236 6237 6238 6239 6240 6241 6242 6243 6244 6245 6246 6247 6248
      <dt><code>spicevmc</code></dt>
      <dd>Paravirtualized SPICE channel. The domain must also have a
        SPICE server as a <a href="#elementsGraphics">graphics
        device</a>, at which point the host piggy-backs messages
        across the <code>main</code> channel.  The <code>target</code>
        element must be present, with
        attribute <code>type='virtio'</code>; an optional
        attribute <code>name</code> controls how the guest will have
        access to the channel, and defaults
        to <code>name='com.redhat.spice.0'</code>.  The
        optional <code>address</code> element can tie the channel to a
        particular <code>type='virtio-serial'</code> controller.
        <span class="since">Since 0.8.8</span></dd>
6249 6250
    </dl>

6251 6252 6253 6254 6255 6256
    <h5><a name="elementsCharHostInterface">Host interface</a></h5>

    <p>
      A character device presents itself to the host as one of the following
      types.
    </p>
D
Daniel P. Berrange 已提交
6257

6258
    <h6><a name="elementsCharSTDIO">Domain logfile</a></h6>
D
Daniel P. Berrange 已提交
6259 6260 6261 6262 6263 6264

    <p>
      This disables all input on the character device, and sends output
      into the virtual machine's logfile
    </p>

6265
<pre>
6266 6267 6268 6269 6270 6271 6272
...
&lt;devices&gt;
  &lt;console type='stdio'&gt;
    &lt;target port='1'/&gt;
  &lt;/console&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6273 6274


6275
    <h6><a name="elementsCharFle">Device logfile</a></h6>
D
Daniel P. Berrange 已提交
6276 6277 6278 6279 6280 6281

    <p>
      A file is opened and all data sent to the character
      device is written to the file.
    </p>

6282
<pre>
6283 6284 6285 6286 6287 6288 6289 6290
...
&lt;devices&gt;
  &lt;serial type="file"&gt;
    &lt;source path="/var/log/vm/vm-serial.log"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6291

6292
    <h6><a name="elementsCharVC">Virtual console</a></h6>
D
Daniel P. Berrange 已提交
6293 6294 6295 6296 6297 6298 6299

    <p>
      Connects the character device to the graphical framebuffer in
      a virtual console. This is typically accessed via a special
      hotkey sequence such as "ctrl+alt+3"
    </p>

6300
<pre>
6301 6302 6303 6304 6305 6306 6307
...
&lt;devices&gt;
  &lt;serial type='vc'&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6308

6309
    <h6><a name="elementsCharNull">Null device</a></h6>
D
Daniel P. Berrange 已提交
6310 6311 6312 6313 6314 6315

    <p>
      Connects the character device to the void. No data is ever
      provided to the input. All data written is discarded.
    </p>

6316
<pre>
6317 6318 6319 6320 6321 6322 6323
...
&lt;devices&gt;
  &lt;serial type='null'&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6324

6325
    <h6><a name="elementsCharPTY">Pseudo TTY</a></h6>
D
Daniel P. Berrange 已提交
6326 6327 6328 6329 6330 6331 6332

    <p>
      A Pseudo TTY is allocated using /dev/ptmx. A suitable client
      such as 'virsh console' can connect to interact with the
      serial port locally.
    </p>

6333
<pre>
6334 6335 6336 6337 6338 6339 6340 6341
...
&lt;devices&gt;
  &lt;serial type="pty"&gt;
    &lt;source path="/dev/pts/3"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6342 6343 6344

    <p>
      NB special case if &lt;console type='pty'&gt;, then the TTY
A
Atsushi SAKAI 已提交
6345
      path is also duplicated as an attribute tty='/dev/pts/3'
D
Daniel P. Berrange 已提交
6346 6347 6348 6349
      on the top level &lt;console&gt; tag. This provides compat
      with existing syntax for &lt;console&gt; tags.
    </p>

6350
    <h6><a name="elementsCharHost">Host device proxy</a></h6>
D
Daniel P. Berrange 已提交
6351 6352 6353 6354 6355

    <p>
      The character device is passed through to the underlying
      physical character device. The device types must match,
      eg the emulated serial port should only be connected to
A
Atsushi SAKAI 已提交
6356
      a host serial port - don't connect a serial port to a parallel
D
Daniel P. Berrange 已提交
6357 6358 6359
      port.
    </p>

6360
<pre>
6361 6362 6363 6364 6365 6366 6367 6368
...
&lt;devices&gt;
  &lt;serial type="dev"&gt;
    &lt;source path="/dev/ttyS0"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6369

6370
    <h6><a name="elementsCharPipe">Named pipe</a></h6>
6371 6372 6373 6374 6375 6376

    <p>
      The character device writes output to a named pipe. See pipe(7) for
      more info.
    </p>

6377
<pre>
6378 6379 6380 6381 6382 6383 6384 6385
...
&lt;devices&gt;
  &lt;serial type="pipe"&gt;
    &lt;source path="/tmp/mypipe"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
6386

6387
    <h6><a name="elementsCharTCP">TCP client/server</a></h6>
D
Daniel P. Berrange 已提交
6388 6389 6390

    <p>
      The character device acts as a TCP client connecting to a
6391
      remote server.
D
Daniel P. Berrange 已提交
6392 6393
    </p>

6394
<pre>
6395 6396 6397 6398 6399 6400 6401 6402 6403
...
&lt;devices&gt;
  &lt;serial type="tcp"&gt;
    &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
    &lt;protocol type="raw"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
 ...</pre>
6404 6405 6406 6407 6408

    <p>
      Or as a TCP server waiting for a client connection.
    </p>

6409
<pre>
6410 6411 6412 6413 6414 6415 6416 6417 6418
...
&lt;devices&gt;
  &lt;serial type="tcp"&gt;
    &lt;source mode="bind" host="127.0.0.1" service="2445"/&gt;
    &lt;protocol type="raw"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
6419 6420

    <p>
E
Eric Blake 已提交
6421
      Alternatively you can use <code>telnet</code> instead
J
John Ferlan 已提交
6422 6423 6424 6425 6426 6427 6428
      of <code>raw</code> TCP in order to utilize the telnet protocol
      for the connection.
    </p>
    <p>
      <span class="since">Since 0.8.5,</span> some hypervisors support
      use of either <code>telnets</code> (secure telnet) or <code>tls</code>
      (via secure sockets layer) as the transport protocol for connections.
E
Eric Blake 已提交
6429
    </p>
6430

6431
<pre>
6432 6433 6434 6435 6436 6437 6438
...
&lt;devices&gt;
  &lt;serial type="tcp"&gt;
    &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
    &lt;protocol type="telnet"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
6439
  ...
6440 6441 6442 6443 6444 6445 6446
  &lt;serial type="tcp"&gt;
    &lt;source mode="bind" host="127.0.0.1" service="2445"/&gt;
    &lt;protocol type="telnet"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
6447 6448 6449 6450 6451 6452 6453 6454 6455 6456 6457 6458 6459 6460 6461 6462 6463 6464 6465

    <p>
      <span class="since">Since 2.4.0,</span> the optional attribute
      <code>tls</code> can be used to control whether a chardev
      TCP communication channel would utilize a hypervisor configured
      TLS X.509 certificate environment in order to encrypt the data
      channel. For the QEMU hypervisor, usage of a TLS environment can
      be controlled on the host by the <code>chardev_tls</code> and
      <code>chardev_tls_x509_cert_dir</code> or
      <code>default_tls_x509_cert_dir</code> settings in the file
      /etc/libvirt/qemu.conf. If <code>chardev_tls</code> is enabled,
      then unless the <code>tls</code> attribute is set to "no", libvirt
      will use the host configured TLS environment.
      If <code>chardev_tls</code> is disabled, but the <code>tls</code>
      attribute is set to "yes", then libvirt will attempt to use the
      host TLS environment if either the <code>chardev_tls_x509_cert_dir</code>
      or <code>default_tls_x509_cert_dir</code> TLS directory structure exists.
    </p>
<pre>
6466 6467 6468 6469 6470 6471 6472 6473 6474
...
&lt;devices&gt;
  &lt;serial type="tcp"&gt;
    &lt;source mode='connect' host="127.0.0.1" service="5555" tls="yes"/&gt;
    &lt;protocol type="raw"/&gt;
    &lt;target port="0"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6475

6476
    <h6><a name="elementsCharUDP">UDP network console</a></h6>
D
Daniel P. Berrange 已提交
6477 6478 6479 6480 6481 6482

    <p>
      The character device acts as a UDP netconsole service,
      sending and receiving packets. This is a lossy service.
    </p>

6483
<pre>
6484 6485 6486 6487 6488 6489 6490 6491 6492
...
&lt;devices&gt;
  &lt;serial type="udp"&gt;
    &lt;source mode="bind" host="0.0.0.0" service="2445"/&gt;
    &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6493

6494
    <h6><a name="elementsCharUNIX">UNIX domain socket client/server</a></h6>
D
Daniel P. Berrange 已提交
6495 6496 6497 6498 6499 6500

    <p>
      The character device acts as a UNIX domain socket server,
      accepting connections from local clients.
    </p>

6501
<pre>
6502 6503 6504 6505 6506 6507 6508 6509
...
&lt;devices&gt;
  &lt;serial type="unix"&gt;
    &lt;source mode="bind" path="/tmp/foo"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
D
Daniel P. Berrange 已提交
6510

6511 6512 6513 6514 6515 6516 6517
    <h6><a name="elementsCharSpiceport">Spice channel</a></h6>

    <p>
      The character device is accessible through spice connection
      under a channel name specified in the <code>channel</code>
      attribute.  <span class="since">Since 1.2.2</span>
    </p>
6518 6519 6520 6521 6522
    <p>
      Note: depending on the hypervisor, spiceports might (or might not)
      be enabled on domains with or without <a href="#elementsGraphics">spice
      graphics</a>.
    </p>
6523 6524

<pre>
6525 6526 6527 6528 6529 6530 6531 6532
...
&lt;devices&gt;
  &lt;serial type="spiceport"&gt;
    &lt;source channel="org.qemu.console.serial.0"/&gt;
    &lt;target port="1"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
6533

6534 6535 6536 6537
    <h6><a name="elementsNmdm">Nmdm device</a></h6>

    <p>
      The nmdm device driver, available on FreeBSD, provides two
C
Chen Hanxiao 已提交
6538
      tty devices connected together by a virtual null modem cable.
6539 6540 6541 6542
      <span class="since">Since 1.2.4</span>
    </p>

<pre>
6543 6544 6545 6546 6547 6548 6549
...
&lt;devices&gt;
  &lt;serial type="nmdm"&gt;
    &lt;source master="/dev/nmdm0A" slave="/dev/nmdm0B"/&gt;
  &lt;/serial&gt;
&lt;/devices&gt;
...</pre>
6550 6551 6552 6553 6554 6555 6556

    <p>
      The <code>source</code> element has these attributes:
    </p>

    <dl>
      <dt><code>master</code></dt>
6557 6558
      <dd>Master device of the pair, that is passed to the hypervisor.
      Device is specified by a fully qualified path.</dd>
6559 6560 6561

      <dt><code>slave</code></dt>
      <dd>Slave device of the pair, that is passed to the clients for connection
6562
      to the guest console. Device is specified by a fully qualified path.</dd>
6563
    </dl>
6564 6565 6566 6567 6568 6569 6570 6571

    <h4><a name="elementsSound">Sound devices</a></h4>

    <p>
      A virtual sound card can be attached to the host via the
      <code>sound</code> element. <span class="since">Since 0.4.3</span>
    </p>

6572
<pre>
6573 6574 6575 6576 6577
...
&lt;devices&gt;
  &lt;sound model='es1370'/&gt;
&lt;/devices&gt;
...</pre>
6578 6579 6580 6581 6582 6583 6584

    <dl>
      <dt><code>sound</code></dt>
      <dd>
        The <code>sound</code> element has one mandatory attribute,
        <code>model</code>, which specifies what real sound device is emulated.
        Valid values are specific to the underlying hypervisor, though typical
6585
        choices are 'es1370', 'sb16', 'ac97', 'ich6' and 'usb'.
6586
        (<span class="since">
6587 6588
         'ac97' only since 0.6.0, 'ich6' only since 0.8.8,
         'usb' only since 1.2.7</span>)
6589 6590 6591
      </dd>
    </dl>

6592 6593 6594 6595 6596 6597 6598 6599 6600 6601 6602
    <p>
      <span class="since">Since 0.9.13</span>, a sound element
      with <code>ich6</code> model can have optional
      sub-elements <code>&lt;codec&gt;</code> to attach various audio
      codecs to the audio device. If not specified, a default codec
      will be attached to allow playback and recording. Valid values
      are 'duplex' (advertise a line-in and a line-out) and 'micro'
      (advertise a speaker and a microphone).
    </p>

<pre>
6603 6604 6605 6606 6607 6608 6609
...
&lt;devices&gt;
  &lt;sound model='ich6'&gt;
    &lt;codec type='micro'/&gt;
  &lt;/sound&gt;
&lt;/devices&gt;
...</pre>
6610

E
Eric Blake 已提交
6611 6612 6613
    <p>
      Each <code>sound</code> element has an optional
      sub-element <code>&lt;address&gt;</code> which can tie the
6614 6615
      device to a particular PCI
      slot, <a href="#elementsAddress">documented above</a>.
E
Eric Blake 已提交
6616 6617
    </p>

R
Richard Jones 已提交
6618 6619 6620 6621 6622 6623 6624 6625 6626 6627 6628 6629 6630 6631 6632 6633 6634 6635 6636 6637
    <h4><a name="elementsWatchdog">Watchdog device</a></h4>

    <p>
      A virtual hardware watchdog device can be added to the guest via
      the <code>watchdog</code> element.
      <span class="since">Since 0.7.3, QEMU and KVM only</span>
    </p>

    <p>
      The watchdog device requires an additional driver and management
      daemon in the guest.  Just enabling the watchdog in the libvirt
      configuration does not do anything useful on its own.
    </p>

    <p>
      Currently libvirt does not support notification when the
      watchdog fires.  This feature is planned for a future version of
      libvirt.
    </p>

6638
<pre>
6639 6640 6641 6642 6643
...
&lt;devices&gt;
  &lt;watchdog model='i6300esb'/&gt;
&lt;/devices&gt;
...</pre>
R
Richard Jones 已提交
6644

6645 6646 6647 6648 6649 6650
<pre>
  ...
  &lt;devices&gt;
    &lt;watchdog model='i6300esb' action='poweroff'/&gt;
  &lt;/devices&gt;
&lt;/domain&gt;</pre>
R
Richard Jones 已提交
6651 6652 6653 6654

    <dl>
      <dt><code>model</code></dt>
      <dd>
M
Matthew Booth 已提交
6655
        <p>
R
Richard Jones 已提交
6656
        The required <code>model</code> attribute specifies what real
M
Matthew Booth 已提交
6657 6658 6659 6660 6661 6662 6663 6664 6665 6666
        watchdog device is emulated.  Valid values are specific to the
        underlying hypervisor.
        </p>
        <p>
        QEMU and KVM support:
        </p>
        <ul>
          <li> 'i6300esb' &mdash; the recommended device,
            emulating a PCI Intel 6300ESB </li>
          <li> 'ib700' &mdash; emulating an ISA iBase IB700 </li>
6667
          <li> 'diag288' &mdash; emulating an S390 DIAG288 device
6668
            <span class="since">Since 1.2.17</span></li>
M
Matthew Booth 已提交
6669
        </ul>
R
Richard Jones 已提交
6670 6671 6672
      </dd>
      <dt><code>action</code></dt>
      <dd>
M
Matthew Booth 已提交
6673
        <p>
R
Richard Jones 已提交
6674
        The optional <code>action</code> attribute describes what
M
Matthew Booth 已提交
6675 6676 6677 6678 6679 6680 6681 6682 6683 6684 6685 6686 6687
        action to take when the watchdog expires.  Valid values are
        specific to the underlying hypervisor.
        </p>
        <p>
        QEMU and KVM support:
        </p>
        <ul>
          <li>'reset' &mdash; default, forcefully reset the guest</li>
          <li>'shutdown' &mdash; gracefully shutdown the guest
            (not recommended) </li>
          <li>'poweroff' &mdash; forcefully power off the guest</li>
          <li>'pause' &mdash; pause the guest</li>
          <li>'none' &mdash; do nothing</li>
6688 6689
          <li>'dump' &mdash; automatically dump the guest
            <span class="since">Since 0.8.7</span></li>
6690 6691
          <li>'inject-nmi' &mdash; inject a non-maskable interrupt
            into the guest
6692
            <span class="since">Since 1.2.17</span></li>
M
Matthew Booth 已提交
6693 6694
        </ul>
        <p>
6695
        Note 1: the 'shutdown' action requires that the guest
M
Matthew Booth 已提交
6696 6697 6698 6699 6700
        is responsive to ACPI signals.  In the sort of situations
        where the watchdog has expired, guests are usually unable
        to respond to ACPI signals.  Therefore using 'shutdown'
        is not recommended.
        </p>
6701 6702 6703 6704
        <p>
        Note 2: the directory to save dump files can be configured
        by <code>auto_dump_path</code> in file /etc/libvirt/qemu.conf.
        </p>
R
Richard Jones 已提交
6705 6706 6707
      </dd>
    </dl>

6708 6709 6710 6711 6712 6713 6714 6715 6716
    <h4><a name="elementsMemBalloon">Memory balloon device</a></h4>

    <p>
      A virtual memory balloon device is added to all Xen and KVM/QEMU
      guests. It will be seen as <code>memballoon</code> element.
      It will be automatically added when appropriate, so there is no
      need to explicitly add this element in the guest XML unless a
      specific PCI slot needs to be assigned.
      <span class="since">Since 0.8.3, Xen, QEMU and KVM only</span>
6717 6718 6719
      Additionally, <span class="since">since 0.8.4</span>, if the
      memballoon device needs to be explicitly disabled,
      <code>model='none'</code> may be used.
6720 6721 6722
    </p>

    <p>
J
Ján Tomko 已提交
6723
      Example: automatically added device with KVM
6724 6725
    </p>
<pre>
6726 6727 6728 6729 6730
...
&lt;devices&gt;
  &lt;memballoon model='virtio'/&gt;
&lt;/devices&gt;
...</pre>
6731 6732

    <p>
J
Ján Tomko 已提交
6733
      Example: manually added device with static PCI slot 2 requested
6734 6735 6736 6737
    </p>
<pre>
  ...
  &lt;devices&gt;
J
Ján Tomko 已提交
6738 6739
    &lt;memballoon model='virtio'&gt;
      &lt;address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/&gt;
6740
      &lt;stats period='10'/&gt;
J
Ján Tomko 已提交
6741
    &lt;/memballoon&gt;
6742 6743 6744 6745 6746 6747 6748 6749
  &lt;/devices&gt;
&lt;/domain&gt;</pre>

    <dl>
      <dt><code>model</code></dt>
      <dd>
        <p>
          The required <code>model</code> attribute specifies what type
E
Eric Blake 已提交
6750 6751
          of balloon device is provided. Valid values are specific to
          the virtualization platform
6752 6753 6754 6755 6756 6757
        </p>
        <ul>
          <li>'virtio' &mdash; default with QEMU/KVM</li>
          <li>'xen' &mdash; default with Xen</li>
        </ul>
      </dd>
6758 6759 6760 6761 6762 6763 6764 6765 6766 6767
      <dt><code>autodeflate</code></dt>
      <dd>
        <p>
          The optional <code>autodeflate</code> attribute allows to
          enable/disable (values "on"/"off", respectively) the ability of the
          QEMU virtio memory balloon to release some memory at the last moment
          before a guest's process get killed by Out of Memory killer.
          <span class="since">Since 1.3.1, QEMU and KVM only</span>
        </p>
      </dd>
6768 6769 6770
      <dt><code>period</code></dt>
      <dd>
        <p>
6771 6772 6773 6774 6775 6776 6777 6778 6779 6780 6781
          The optional <code>period</code> allows the QEMU virtio memory balloon
          driver to provide statistics through the <code>virsh dommemstat
          [domain]</code> command. By default, collection is not enabled. In
          order to enable, use the <code>virsh dommemstat [domain] --period
          [number]</code> command or <code>virsh edit</code> command to add the
          option to the XML definition.  The <code>virsh dommemstat</code> will
          accept the options <code>--live</code>, <code>--current</code>,
          or <code>--config</code>.  If an option is not provided, the change
          for a running domain will only be made to the active guest.  If the
          QEMU driver is not at the right revision, the attempt to set the
          period will fail.  Large values (e.g. many years) might be ignored.
6782 6783 6784
          <span class='since'>Since 1.1.1, requires QEMU 1.5</span>
        </p>
      </dd>
6785
    </dl>
6786 6787 6788 6789 6790 6791 6792 6793 6794 6795 6796 6797
    <h4><a name="elementsRng">Random number generator device</a></h4>

    <p>
      The virtual random number generator device allows the host to pass
      through entropy to guest operating systems.
      <span class="since">Since 1.0.3</span>
    </p>

    <p>
      Example: usage of the RNG device:
    </p>
<pre>
6798 6799 6800 6801 6802 6803 6804 6805 6806 6807 6808 6809 6810
...
&lt;devices&gt;
  &lt;rng model='virtio'&gt;
    &lt;rate period="2000" bytes="1234"/&gt;
    &lt;backend model='random'&gt;/dev/random&lt;/backend&gt;
    &lt;!-- OR --&gt;
    &lt;backend model='egd' type='udp'&gt;
      &lt;source mode='bind' service='1234'/&gt;
      &lt;source mode='connect' host='1.2.3.4' service='1234'/&gt;
    &lt;/backend&gt;
  &lt;/rng&gt;
&lt;/devices&gt;
...
6811 6812 6813 6814 6815 6816 6817 6818 6819 6820 6821 6822 6823
</pre>
    <dl>
      <dt><code>model</code></dt>
      <dd>
        <p>
          The required <code>model</code> attribute specifies what type
          of RNG device is provided. Valid values are specific to
          the virtualization platform:
        </p>
        <ul>
          <li>'virtio' &mdash; supported by qemu and virtio-rng kernel module</li>
        </ul>
      </dd>
6824 6825 6826 6827 6828 6829 6830 6831 6832 6833 6834 6835
      <dt><code>rate</code></dt>
      <dd>
        <p>
          The optional <code>rate</code> element allows limiting the rate at
          which entropy can be consumed from the source.  The mandatory
          attribute <code>bytes</code> specifies how many bytes are permitted
          to be consumed per period.  An optional <code>period</code> attribute
          specifies the duration of a period in milliseconds; if omitted, the
          period is taken as 1000 milliseconds (1 second).
          <span class='since'>Since 1.0.4</span>
        </p>
      </dd>
6836 6837 6838 6839 6840 6841 6842
      <dt><code>backend</code></dt>
      <dd>
        <p>
          The <code>backend</code> element specifies the source of entropy
          to be used for the domain. The source model is configured using the
          <code>model</code> attribute. Supported source models are:
        </p>
6843 6844 6845 6846 6847
        <dl>
          <dt><code>random</code></dt>
          <dd>
            <p>
              This backend type expects a non-blocking character device as
6848
              input. The file name is specified as contents of the
6849 6850 6851 6852
              <code>backend</code> element. <span class='since'>Since 1.3.4</span>
              any path is accepted. Before that /dev/random and /dev/hwrng were
              the only accepted paths. When no file name is specified the hypervisor
              default is used. For qemu, the default is /dev/random
6853 6854 6855 6856 6857 6858 6859 6860 6861 6862 6863 6864
            </p>
          </dd>
          <dt><code>egd</code></dt>
          <dd>
            <p>
              This backend connects to a source using the EGD protocol.
              The source is specified as a character device. Refer to
              <a href='#elementsCharHostInterface'>character device host interface</a>
              for more information.
            </p>
          </dd>
        </dl>
6865 6866 6867
      </dd>

    </dl>
6868

6869 6870 6871 6872 6873 6874 6875 6876
    <h4><a name="elementsTpm">TPM device</a></h4>

    <p>
      The TPM device enables a QEMU guest to have access to TPM
      functionality.
    </p>
    <p>
      The TPM passthrough device type provides access to the host's TPM
6877
      for one QEMU guest. No other software may be using the TPM device,
6878 6879 6880 6881 6882 6883 6884 6885
      typically /dev/tpm0, at the time the QEMU guest is started.
      <span class="since">'passthrough' since 1.0.5</span>
    </p>

    <p>
     Example: usage of the TPM passthrough device
    </p>
<pre>
6886 6887 6888 6889 6890 6891 6892 6893 6894
...
&lt;devices&gt;
  &lt;tpm model='tpm-tis'&gt;
    &lt;backend type='passthrough'&gt;
      &lt;device path='/dev/tpm0'/&gt;
    &lt;/backend&gt;
  &lt;/tpm&gt;
&lt;/devices&gt;
...
6895 6896 6897 6898 6899 6900 6901 6902 6903 6904 6905 6906 6907 6908 6909 6910
</pre>
    <dl>
      <dt><code>model</code></dt>
      <dd>
        <p>
          The <code>model</code> attribute specifies what device
          model QEMU provides to the guest. If no model name is provided,
          <code>tpm-tis</code> will automatically be chosen.
        </p>
      </dd>
      <dt><code>backend</code></dt>
      <dd>
        <p>
          The <code>backend</code> element specifies the type of
          TPM device. The following types are supported:
        </p>
6911 6912 6913 6914 6915 6916 6917 6918 6919 6920 6921 6922 6923 6924 6925
        <dl>
          <dt><code>passthrough</code></dt>
          <dd>
            <p>
              Use the host's TPM device.
            </p>
            <p>
              This backend type requires exclusive access to a TPM device on
              the host. An example for such a device is /dev/tpm0. The fully
              qualified file name is specified by path attribute of the
              <code>source</code> element. If no file name is specified then
              /dev/tpm0 is automatically used.
            </p>
          </dd>
        </dl>
6926 6927 6928
      </dd>
    </dl>

L
Li Zhang 已提交
6929 6930 6931 6932 6933 6934 6935 6936 6937 6938 6939
    <h4><a name="elementsNVRAM">NVRAM device</a></h4>
    <p>
      nvram device is always added to pSeries guest on PPC64, and its address
      is allowed to be changed.  Element <code>nvram</code> (only valid for
      pSeries guest, <span class="since">since 1.0.5</span>) is provided to
      enable the address setting.
    </p>
    <p>
      Example: usage of NVRAM configuration
    </p>
<pre>
6940 6941 6942 6943 6944 6945 6946
...
&lt;devices&gt;
  &lt;nvram&gt;
    &lt;address type='spapr-vio' reg='0x3000'/&gt;
  &lt;/nvram&gt;
&lt;/devices&gt;
...
L
Li Zhang 已提交
6947 6948 6949 6950 6951 6952 6953 6954 6955 6956 6957 6958 6959 6960 6961 6962
</pre>
  <dl>
    <dt><code>spapr-vio</code></dt>
    <dd>
      <p>
        VIO device address type, only valid for PPC64.
      </p>
    </dd>
    <dt><code>reg</code></dt>
    <dd>
      <p>
        Device address
      </p>
    </dd>
  </dl>

H
Hu Tao 已提交
6963 6964 6965 6966 6967 6968
    <h4><a name="elementsPanic">panic device</a></h4>
    <p>
      panic device enables libvirt to receive panic notification from a QEMU
      guest.
      <span class="since">Since 1.2.1, QEMU and KVM only</span>
    </p>
6969
    <p>
6970 6971 6972 6973 6974 6975 6976 6977 6978
      This feature is always enabled for:
    </p>
    <ul>
      <li>pSeries guests, since it's implemented by the guest firmware</li>
      <li>S390 guests, since it's an integral part of the S390 architecture</li>
    </ul>
    <p>
      For the guest types listed above, libvirt automatically adds a
      <code>panic</code> element to the domain XML.
6979
    </p>
H
Hu Tao 已提交
6980 6981 6982 6983
    <p>
      Example: usage of panic configuration
    </p>
<pre>
6984 6985 6986 6987 6988 6989 6990 6991
...
&lt;devices&gt;
  &lt;panic model='hyperv'/&gt;
  &lt;panic model='isa'&gt;
    &lt;address type='isa' iobase='0x505'/&gt;
  &lt;/panic&gt;
&lt;/devices&gt;
...
H
Hu Tao 已提交
6992 6993
</pre>
  <dl>
6994 6995 6996 6997 6998 6999 7000 7001 7002 7003 7004 7005
    <dt><code>model</code></dt>
      <dd>
        <p>
          The optional <code>model</code> attribute specifies what type
          of panic device is provided. The panic model used when this attribute
          is missing depends on the hypervisor and guest arch.
        </p>
        <ul>
          <li>'isa' &mdash; for ISA pvpanic device</li>
          <li>'pseries' &mdash; default and valid only for pSeries guests.</li>
          <li>'hyperv' &mdash; for Hyper-V crash CPU feature.
            <span class="since">Since 1.3.0, QEMU and KVM only</span></li>
7006 7007
          <li>'s390' &mdash; default for S390 guests.
            <span class="since">Since 1.3.5</span></li>
7008 7009
        </ul>
      </dd>
H
Hu Tao 已提交
7010 7011 7012 7013
    <dt><code>address</code></dt>
    <dd>
      <p>
        address of panic. The default ioport is 0x505. Most users
7014
        don't need to specify an address, and doing so is forbidden
7015
        altogether for s390, pseries and hyperv models.
H
Hu Tao 已提交
7016 7017 7018 7019
      </p>
    </dd>
  </dl>

7020 7021 7022 7023 7024
  <h4><a name="elementsShmem">Shared memory device</a></h4>

    <p>
      A shared memory device allows to share a memory region between
      different virtual machines and the host.
M
Martin Kletzander 已提交
7025
      <span class="since">Since 1.2.10, QEMU and KVM only</span>
7026 7027 7028
    </p>

<pre>
7029 7030 7031 7032 7033 7034 7035 7036 7037 7038 7039 7040 7041 7042
...
&lt;devices&gt;
  &lt;shmem name='my_shmem0'&gt;
    &lt;model type='ivshmem-plain'/&gt;
    &lt;size unit='M'&gt;4&lt;/size&gt;
  &lt;/shmem&gt;
  &lt;shmem name='shmem_server'&gt;
    &lt;model type='ivshmem-doorbell'/&gt;
    &lt;size unit='M'&gt;2&lt;/size&gt;
    &lt;server path='/tmp/socket-shmem'/&gt;
    &lt;msi vectors='32' ioeventfd='on'/&gt;
  &lt;/shmem&gt;
&lt;/devices&gt;
...
7043 7044 7045 7046 7047 7048 7049 7050
</pre>

  <dl>
    <dt><code>shmem</code></dt>
    <dd>
      The <code>shmem</code> element has one mandatory attribute,
      <code>name</code> to identify the shared memory.
    </dd>
7051 7052 7053 7054
    <dt><code>model</code></dt>
    <dd>
      Attribute <code>type</code> of the optional element <code>model</code>
      specifies the model of the underlying device providing the
7055 7056 7057 7058 7059
      <code>shmem</code> device.  The models currently supported are
      <code>ivshmem</code> (supports both server and server-less shmem, but is
      deprecated by newer QEMU in favour of the -plain and -doorbell variants),
      <code>ivshmem-plain</code> (only for server-less shmem) and
      <code>ivshmem-doorbell</code> (only for shmem with the server).
7060
    </dd>
7061 7062 7063 7064 7065 7066 7067 7068 7069
    <dt><code>size</code></dt>
    <dd>
      The optional <code>size</code> element specifies the size of the shared
      memory. This must be power of 2 and greater than or equal to 1 MiB.
    </dd>
    <dt><code>server</code></dt>
    <dd>
      The optional <code>server</code> element can be used to configure a server
      socket the device is supposed to connect to.  The optional
7070 7071
      <code>path</code> attribute specifies the absolute path to the unix socket
      and defaults to <code>/var/lib/libvirt/shmem/$shmem-$name-sock</code>.
7072 7073 7074 7075 7076 7077 7078 7079 7080 7081 7082 7083
    </dd>
    <dt><code>msi</code></dt>
    <dd>
      The optional <code>msi</code> element enables/disables (values "on"/"off",
      respectively) MSI interrupts. This option can currently be used only
      together with the <code>server</code> element. The <code>vectors</code>
      attribute can be used to specify the number of interrupt
      vectors. The <code>ioeventd</code> attribute enables/disables (values
      "on"/"off", respectively) ioeventfd.
    </dd>
  </dl>

7084 7085 7086 7087 7088 7089 7090 7091 7092 7093 7094 7095 7096 7097 7098 7099 7100
    <h4><a name="elementsMemory">Memory devices</a></h4>

    <p>
        In addition to the initial memory assigned to the guest, memory devices
        allow additional memory to be assigned to the guest in the form of
        memory modules.

        A memory device can be hot-plugged or hot-unplugged depending on the
        guests' memory resource needs.

        Some hypervisors may require NUMA configured for the guest.
    </p>

    <p>
      Example: usage of the memory devices
    </p>
<pre>
7101 7102
...
&lt;devices&gt;
7103
  &lt;memory model='dimm' access='private'&gt;
7104 7105 7106 7107 7108 7109 7110 7111 7112 7113 7114 7115 7116 7117 7118
    &lt;target&gt;
      &lt;size unit='KiB'&gt;524287&lt;/size&gt;
      &lt;node&gt;0&lt;/node&gt;
    &lt;/target&gt;
  &lt;/memory&gt;
  &lt;memory model='dimm'&gt;
    &lt;source&gt;
      &lt;pagesize unit='KiB'&gt;4096&lt;/pagesize&gt;
      &lt;nodemask&gt;1-3&lt;/nodemask&gt;
    &lt;/source&gt;
    &lt;target&gt;
      &lt;size unit='KiB'&gt;524287&lt;/size&gt;
      &lt;node&gt;1&lt;/node&gt;
    &lt;/target&gt;
  &lt;/memory&gt;
M
Michal Privoznik 已提交
7119 7120 7121 7122 7123 7124 7125
  &lt;memory model='nvdimm'&gt;
    &lt;source&gt;
      &lt;path&gt;/tmp/nvdimm&lt;/path&gt;
    &lt;/source&gt;
    &lt;target&gt;
      &lt;size unit='KiB'&gt;524288&lt;/size&gt;
      &lt;node&gt;1&lt;/node&gt;
7126 7127 7128
      &lt;label&gt;
        &lt;size unit='KiB'&gt;128&lt;/size&gt;
      &lt;/label&gt;
M
Michal Privoznik 已提交
7129 7130
    &lt;/target&gt;
  &lt;/memory&gt;
7131 7132
&lt;/devices&gt;
...
7133 7134 7135 7136 7137
</pre>
    <dl>
      <dt><code>model</code></dt>
      <dd>
        <p>
M
Michal Privoznik 已提交
7138 7139 7140 7141
          Provide <code>dimm</code> to add a virtual DIMM module to the guest.
          <span class="since">Since 1.2.14</span>
          Provide <code>nvdimm</code> model adds a Non-Volatile DIMM
          module. <span class="since">Since 3.2.0</span>
7142 7143 7144
        </p>
      </dd>

7145 7146 7147 7148 7149 7150 7151 7152 7153 7154 7155 7156
      <dt><code>access</code></dt>
      <dd>
        <p>
          An optional attribute <code>access</code>
          (<span class="since">since 3.2.0</span>) that provides
          capability to fine tune mapping of the memory on per
          module basis. Values are the same as
          <a href="#elementsMemoryBacking">Memory Backing</a>:
          <code>shared</code> and <code>private</code>.
        </p>
      </dd>

7157 7158 7159
      <dt><code>source</code></dt>
      <dd>
        <p>
M
Michal Privoznik 已提交
7160 7161 7162 7163 7164
          For model <code>dimm</code> this element is optional and allows to
          fine tune the source of the memory used for the given memory device.
          If the element is not provided defaults configured via
          <code>numatune</code> are used. If <code>dimm</code> is provided,
          then the following optional elements can be provided as well:
7165 7166
        </p>

M
Michal Privoznik 已提交
7167 7168 7169 7170 7171 7172 7173 7174 7175 7176 7177 7178 7179 7180 7181 7182 7183 7184 7185 7186 7187
        <dl>
          <dt><code>pagesize</code></dt>
          <dd>
            <p>
              This element can be used to override the default
              host page size used for backing the memory device.
              The configured value must correspond to a page size
              supported by the host.
            </p>
          </dd>

          <dt><code>nodemask</code></dt>
          <dd>
            <p>
              This element can be used to override the default
              set of NUMA nodes where the memory would be
              allocated.
            </p>
          </dd>
        </dl>

7188
        <p>
M
Michal Privoznik 已提交
7189 7190 7191
          For model <code>nvdimm</code> this element is mandatory and has a
          single child element <code>path</code> that represents a path
          in the host that backs the nvdimm module in the guest.
7192 7193 7194 7195 7196 7197 7198 7199 7200 7201 7202 7203 7204 7205
        </p>
      </dd>

      <dt><code>target</code></dt>
      <dd>
        <p>
          The mandatory <code>target</code> element configures the placement and
          sizing of the added memory from the perspective of the guest.
        </p>
        <p>
          The mandatory <code>size</code> subelement configures the size of the
          added memory as a scaled integer.
        </p>
        <p>
7206 7207 7208
          The <code>node</code> subelement configures the guest NUMA node to
          attach the memory to. The element shall be used only if the guest has
          NUMA nodes configured.
7209
        </p>
7210 7211 7212 7213 7214 7215 7216 7217 7218 7219 7220 7221 7222 7223
        <p>
          For NVDIMM type devices one can optionally use
          <code>label</code> and its subelement <code>size</code>
          to configure the size of namespaces label storage
          within the NVDIMM module. The <code>size</code> element
          has usual meaning described
          <a href="#elementsMemoryAllocation">here</a>.
          For QEMU domains the following restrictions apply:
        </p>
        <ol>
          <li>the minimum label size is 128KiB,</li>
          <li>the remaining size (total-size - label-size) has to be aligned to
            4KiB</li>
        </ol>
7224 7225 7226
      </dd>
    </dl>

J
Ján Tomko 已提交
7227 7228 7229 7230 7231 7232 7233 7234 7235 7236 7237
    <h4><a name="elementsIommu">IOMMU devices</a></h4>

    <p>
      The <code>iommu</code> element can be used to add an IOMMU device.
      <span class="since">Since 2.1.0</span>
    </p>

    <p>
      Example:
    </p>
<pre>
7238 7239 7240 7241 7242
...
&lt;devices&gt;
  &lt;iommu model='intel'/&gt;
&lt;/devices&gt;
...
J
Ján Tomko 已提交
7243 7244 7245 7246 7247 7248 7249 7250 7251 7252
</pre>
    <dl>
      <dt><code>model</code></dt>
      <dd>
        <p>
          Currently only the <code>intel</code> model is supported.
        </p>
      </dd>
    </dl>

7253 7254 7255 7256
    <h3><a name="seclabel">Security label</a></h3>

    <p>
      The <code>seclabel</code> element allows control over the
7257 7258 7259 7260 7261
      operation of the security drivers. There are three basic
      modes of operation, 'dynamic' where libvirt automatically
      generates a unique security label, 'static' where the
      application/administrator chooses the labels, or 'none'
      where confinement is disabled. With dynamic
7262 7263 7264 7265 7266
      label generation, libvirt will always automatically
      relabel any resources associated with the virtual machine.
      With static label assignment, by default, the administrator
      or application must ensure labels are set correctly on any
      resources, however, automatic relabeling can be enabled
7267 7268
      if desired.  <span class="since">'dynamic' since 0.6.1, 'static'
      since 0.6.2, and 'none' since 0.9.10.</span>
7269 7270
    </p>

7271 7272 7273 7274 7275 7276 7277
    <p>
      If more than one security driver is used by libvirt, multiple
      <code>seclabel</code> tags can be used, one for each driver and
      the security driver referenced by each tag can be defined using
      the attribute <code>model</code>
    </p>

7278
    <p>
7279
      Valid input XML configurations for the top-level security label
7280 7281 7282 7283
      are:
    </p>

    <pre>
7284
&lt;seclabel type='dynamic' model='selinux'/&gt;
7285

7286 7287 7288
&lt;seclabel type='dynamic' model='selinux'&gt;
  &lt;baselabel&gt;system_u:system_r:my_svirt_t:s0&lt;/baselabel&gt;
&lt;/seclabel&gt;
7289

7290 7291 7292
&lt;seclabel type='static' model='selinux' relabel='no'&gt;
  &lt;label&gt;system_u:system_r:svirt_t:s0:c392,c662&lt;/label&gt;
&lt;/seclabel&gt;
7293

7294 7295 7296
&lt;seclabel type='static' model='selinux' relabel='yes'&gt;
  &lt;label&gt;system_u:system_r:svirt_t:s0:c392,c662&lt;/label&gt;
&lt;/seclabel&gt;
7297

7298
&lt;seclabel type='none'/&gt;
7299 7300
    </pre>

7301 7302 7303 7304 7305 7306 7307
    <p>
      If no 'type' attribute is provided in the input XML, then
      the security driver default setting will be used, which
      may be either 'none' or 'dynamic'. If a 'baselabel' is set
      but no 'type' is set, then the type is presumed to be 'dynamic'
    </p>

7308 7309 7310 7311 7312 7313 7314 7315 7316
    <p>
      When viewing the XML for a running guest with automatic
      resource relabeling active, an additional XML element,
      <code>imagelabel</code>, will be included. This is an
      output-only element, so will be ignored in user supplied
      XML documents
    </p>
    <dl>
      <dt><code>type</code></dt>
7317 7318 7319
      <dd>Either <code>static</code>, <code>dynamic</code> or <code>none</code>
        to determine whether libvirt automatically generates a unique security
        label or not.
7320 7321 7322 7323 7324 7325 7326 7327 7328 7329 7330 7331 7332
      </dd>
      <dt><code>model</code></dt>
      <dd>A valid security model name, matching the currently
        activated security model
      </dd>
      <dt><code>relabel</code></dt>
      <dd>Either <code>yes</code> or <code>no</code>. This must always
        be <code>yes</code> if dynamic label assignment is used. With
        static label assignment it will default to <code>no</code>.
      </dd>
      <dt><code>label</code></dt>
      <dd>If static labelling is used, this must specify the full
        security label to assign to the virtual domain. The format
7333 7334 7335 7336 7337 7338 7339 7340 7341 7342 7343
        of the content depends on the security driver in use:
        <ul>
          <li>SELinux: a SELinux context.</li>
          <li>AppArmor: an AppArmor profile.</li>
          <li>
            DAC: owner and group separated by colon. They can be
            defined both as user/group names or uid/gid. The driver will first
            try to parse these values as names, but a leading plus sign can
            used to force the driver to parse them as uid or gid.
          </li>
        </ul>
7344 7345 7346
      </dd>
      <dt><code>baselabel</code></dt>
      <dd>If dynamic labelling is used, this can optionally be
7347 7348 7349 7350 7351 7352 7353 7354 7355 7356
        used to specify the base security label that will be used to generate
        the actual label. The format of the content depends on the security
        driver in use.

        The SELinux driver uses only the <code>type</code> field of the
        baselabel in the generated label. Other fields are inherited from
        the parent process when using SELinux baselabels.

        (The example above demonstrates the use of <code>my_svirt_t</code>
        as the value for the <code>type</code> field.)
7357 7358 7359 7360 7361 7362 7363 7364
      </dd>
      <dt><code>imagelabel</code></dt>
      <dd>This is an output only element, which shows the
        security label used on resources associated with the virtual domain.
        The format of the content depends on the security driver in use
      </dd>
    </dl>

7365 7366 7367 7368 7369 7370 7371 7372 7373 7374
    <p>When relabeling is in effect, it is also possible to fine-tune
      the labeling done for specific source file names, by either
      disabling the labeling (useful if the file lives on NFS or other
      file system that lacks security labeling) or requesting an
      alternate label (useful when a management application creates a
      special label to allow sharing of some, but not all, resources
      between domains), <span class="since">since 0.9.9</span>.  When
      a <code>seclabel</code> element is attached to a specific path
      rather than the top-level domain assignment, only the
      attribute <code>relabel</code> or the
7375 7376 7377 7378 7379
      sub-element <code>label</code> are supported.  Additionally,
      <span class="since">since 1.1.2</span>, an output-only
      element <code>labelskip</code> will be present for active
      domains on disks where labeling was skipped due to the image
      being on a file system that lacks security labeling.
7380 7381
    </p>

7382 7383 7384 7385 7386 7387 7388 7389 7390 7391 7392 7393 7394 7395 7396 7397 7398 7399 7400 7401 7402 7403 7404 7405 7406 7407 7408 7409 7410 7411 7412 7413 7414 7415 7416 7417 7418 7419 7420
    <h3><a name="keywrap">Key Wrap</a></h3>

       <p>The content of the optional <code>keywrap</code> element specifies
        whether the guest will be allowed to perform the S390 cryptographic key
        management operations. A clear key can be protected by encrypting it
        under a unique wrapping key that is generated for each guest VM running
        on the host. Two variations of wrapping keys are generated: one version
        for encrypting protected keys using the DEA/TDEA algorithm, and another
        version for keys encrypted using the AES algorithm. If a
        <code>keywrap</code> element is not included, the guest will be granted
        access to both AES and DEA/TDEA key wrapping by default.</p>

        <pre>
&lt;domain&gt;
  ...
  &lt;keywrap&gt;
    &lt;cipher name='aes' state='off'/&gt;
  &lt;/keywrap&gt;
  ...
&lt;/domain&gt;
</pre>
    <p>
      At least one <code>cipher</code> element must be nested within the
      <code>keywrap</code> element.
    </p>
    <dl>
      <dt><code>cipher</code></dt>
      <dd>The <code>name</code> attribute identifies the algorithm
        for encrypting a protected key. The values supported for this attribute
        are <code>aes</code> for encryption under the AES wrapping key, or
        <code>dea</code> for encryption under the DEA/TDEA wrapping key. The
        <code>state</code> attribute indicates whether the cryptographic key
        management operations should be turned on for the specified encryption
        algorithm. The value can be set to <code>on</code> or <code>off</code>.
      </dd>
    </dl>

    <p>Note: DEA/TDEA is synonymous with DES/TDES.</p>

D
Daniel P. Berrange 已提交
7421
    <h2><a name="examples">Example configs</a></h2>
7422 7423 7424 7425 7426 7427 7428 7429 7430 7431 7432 7433

    <p>
      Example configurations for each driver are provide on the
      driver specific pages listed below
    </p>

    <ul>
      <li><a href="drvxen.html#xmlconfig">Xen examples</a></li>
      <li><a href="drvqemu.html#xmlconfig">QEMU/KVM examples</a></li>
    </ul>
  </body>
</html>