1. 30 1月, 2019 2 次提交
  2. 13 12月, 2018 1 次提交
  3. 20 9月, 2018 2 次提交
  4. 06 8月, 2018 1 次提交
  5. 03 11月, 2017 1 次提交
    • A
      Remove backslash alignment attempts · 3e7db8d3
      Andrea Bolognani 提交于
      Right-aligning backslashes when defining macros or using complex
      commands in Makefiles looks cute, but as soon as any changes is
      required to the code you end up with either distractingly broken
      alignment or unnecessarily big diffs where most of the changes
      are just pushing all backslashes a few characters to one side.
      
      Generated using
      
        $ git grep -El '[[:blank:]][[:blank:]]\\$' | \
          grep -E '*\.([chx]|am|mk)$$' | \
          while read f; do \
            sed -Ei 's/[[:blank:]]*[[:blank:]]\\$/ \\/g' "$f"; \
          done
      Signed-off-by: NAndrea Bolognani <abologna@redhat.com>
      3e7db8d3
  6. 04 4月, 2017 1 次提交
  7. 29 3月, 2017 1 次提交
  8. 21 2月, 2017 1 次提交
  9. 26 1月, 2017 1 次提交
  10. 08 6月, 2016 2 次提交
  11. 29 3月, 2016 1 次提交
  12. 20 1月, 2016 1 次提交
    • J
      conf: Add storage pool device attribute part_separator · 4f846170
      John Ferlan 提交于
      Add a new storage pool source device attribute 'part_separator=[yes|no]'
      in order to allow a 'disk' storage pool using a device mapper multipath
      device to not add the "p" partition separator to the generated device
      name when libvirt_parthelper is run.
      
      This will allow libvirt to find device mapper multipath devices which were
      configured in /etc/multipath.conf to use 'user_friendly_names' or custom
      'alias' names for the LUN.
      4f846170
  13. 16 6月, 2015 1 次提交
    • J
      storage: Fix the schema and add tests for cifs pool · 38c94948
      John Ferlan 提交于
      Commit id '887dd362' added support for a netfs pool format type 'cifs'
      and 'gluster' in order to add rng support for Samba and glusterfs netfs
      pools. Originally, the CIFS type support was added as part of commit
      id '61fb6979'. Eventually commit id 'b325be12' fixed the gluster rng
      definition to match expectations.
      
      As it turns out the CIFS rng needed a similar change since the directory
      path is not an absDirPath, rather just a dirPath will be required.
      38c94948
  14. 24 4月, 2015 2 次提交
  15. 19 1月, 2015 1 次提交
    • G
      Make ZFS storage pool XML tests optional · e11490e3
      Gary R Hook 提交于
      Do not run ZFS tests when ZFS is unsupported in the environment.
      
      The recent patch b4af4022 adds tests
      to storagepoolxml2xmltest for the optional ZFS feature. When ZFS is
      not included in the configuration these tests should not / cannot be
      run. Modify the test source file to check for use of the feature and
      compile in the tests accordingly.
      Signed-off-by: NGary R Hook <gary.hook@nimboxx.com>
      e11490e3
  16. 12 11月, 2014 1 次提交
    • J
      storage: Introduce 'managed' for the fchost parent · 5530f248
      John Ferlan 提交于
      https://bugzilla.redhat.com/show_bug.cgi?id=1160926
      
      Introduce a 'managed' attribute to allow libvirt to decide whether to
      delete a vHBA vport created via external means such as nodedev-create.
      The code currently decides whether to delete the vHBA based solely on
      whether the parent was provided at creation time. However, that may not
      be the desired action, so rather than delete and force someone to create
      another vHBA via an additional nodedev-create allow the configuration of
      the storage pool to decide the desired action.
      
      During createVport when libvirt does the VPORT_CREATE, set the managed
      value to YES if not already set to indicate to the deleteVport code that
      it should delete the vHBA when the pool is destroyed.
      
      If libvirtd is restarted all the memory only state was lost, so for a
      persistent storage pool, use the virStoragePoolSaveConfig in order to
      write out the managed value.
      
      Because we're now saving the current configuration, we need to be sure
      to not save the parent in the output XML if it was undefined at start.
      Saving the name would cause future starts to always use the same parent
      which is not the expected result when not providing a parent. By not
      providing a parent, libvirt is expected to find the best available
      vHBA port for each subsequent (re)start.
      
      At deleteVport, use the new managed value to decide whether to execute
      the VPORT_DELETE.  Since we no longer save the parent in memory or in
      XML when provided, if it was not provided, then we have to look it up.
      5530f248
  17. 18 9月, 2014 1 次提交
    • R
      storage: zfs: implement pool build and delete · b4af4022
      Roman Bogorodskiy 提交于
       - Provide an implementation for buildPool and deletePool operations
         for the ZFS storage backend.
       - Add VIR_STORAGE_POOL_SOURCE_DEVICE flag to ZFS pool poolOptions
         as now we can specify devices to build pool from
       - storagepool.rng: add an optional 'sourceinfodev' to 'sourcezfs' and
         add an optional 'target' to 'poolzfs' entity
       - Add a couple of tests to storagepoolxml2xmltest
      b4af4022
  18. 22 7月, 2014 1 次提交
    • O
      storage: Introduce parentaddr into virStoragePoolSourceAdapter · a4bd62ad
      Osier Yang 提交于
      Between reboots and kernel reloads, the SCSI host number used for SCSI
      storage pools may change requiring modification to the storage pool XML
      in order to use a specific SCSI host adapter.
      
      This patch introduces the "parentaddr" element and "unique_id" attribute
      for the SCSI host adapter in order to uniquely identify the adapter
      between reboots and kernel reloads. For now the goal is to only parse
      and format the XML. Both will be required to be provided in order to
      uniquely identify the desired SCSI host.
      
      The new XML is expected to be as follows:
      
        <adapter type='scsi_host'>
          <parentaddr unique_id='3'>
            <address domain='0x0000' bus='0x00' slot='0x1f' func='0x2'/>
          </parentaddr>
        </adapter>
      
      where "parentaddr" is the parent device of the SCSI host using the PCI
      address on which the device resides and the value from the unique_id file
      for the device. Both the PCI address and unique_id values will be used
      to traverse the /sys/class/scsi_host/ directories looking at each link
      to match the PCI address reformatted to the directory link format where
      "domain:bus:slot:function" is found.  Then for each matching directory
      the unique_id file for the scsi_host will be used to match the unique_id
      value in the xml.
      
      For a PCI address listed above, this will be formatted to "0000:00:1f.2"
      and the links in /sys/class/scsi_host will be used to find the host#
      to be used for the 'scsi_host' device. Each entry is a link to the
      /sys/bus/pci/devices directories, e.g.:
      
      %  ls -al /sys/class/scsi_host/host2
      lrwxrwxrwx. 1 root root 0 Jun  1 00:22 /sys/class/scsi_host/host2 -> ../../devices/pci0000:00/0000:00:1f.2/ata3/host2/scsi_host/host2
      
      % cat /sys/class/scsi_host/host2/unique_id
      3
      
      The "parentaddr" and "name" attributes are mutually exclusive to identify
      the SCSI host number. Use of the "parentaddr" element will be the preferred
      mechanism.
      
      This patch only supports to parse and format the XMLs. Later patches will
      add code to find out the scsi host number.
      a4bd62ad
  19. 25 3月, 2014 1 次提交
  20. 18 3月, 2014 1 次提交
  21. 26 11月, 2013 1 次提交
    • E
      storage: document gluster pool · ed5fa7f3
      Eric Blake 提交于
      Add support for a new <pool type='gluster'>, similar to
      RBD and Sheepdog.  Terminology wise, a gluster volume
      forms a libvirt storage pool, within the gluster volume,
      individual files are treated as libvirt storage volumes.
      
      * docs/schemas/storagepool.rng (poolgluster): New pool type.
      * docs/formatstorage.html.in: Document gluster.
      * docs/storage.html.in: Likewise, and contrast it with netfs.
      * tests/storagepoolxml2xmlin/pool-gluster.xml: New test.
      * tests/storagepoolxml2xmlout/pool-gluster.xml: Likewise.
      * tests/storagepoolxml2xmltest.c (mymain): Likewise.
      Signed-off-by: NEric Blake <eblake@redhat.com>
      ed5fa7f3
  22. 22 11月, 2013 1 次提交
    • E
      storage: use valid XML for awkward volume names · 6cc4d6a3
      Eric Blake 提交于
      $ touch /var/lib/libvirt/images/'a<b>c'
      $ virsh pool-refresh default
      $ virsh vol-dumpxml 'a<b>c' default | head -n2
      <volume>
        <name>a<b>c</name>
      
      Oops.  That's not valid XML.  And when we fix the XML
      generation, it fails RelaxNG validation.
      
      I'm also tired of seeing <key>(null)</key> in the example
      output for volume xml; while we used NULLSTR() to avoid
      a NULL deref rather than relying on glibc's printf
      extension behavior, it's even better if we avoid the issue
      in the first place.  But this requires being careful that
      we don't invalidate any storage backends that were relying
      on key being unassigned during virStoragVolCreateXML[From].
      
      I would have split this into two patches (one for escaping,
      one for avoiding <key>(null)</key>), but since they both
      end up touching a lot of the same test files, I ended up
      merging it into one.
      
      Note that this patch allows pretty much any volume name
      that can appear in a directory (excluding . and .. because
      those are special), but does nothing to change the current
      (unenforced) RelaxNG claim that pool names will consist
      only of letters, numbers, _, -, and +.  Tightening the C
      code to match RelaxNG patterns and/or relaxing the grammar
      to match the C code for pool names is a task for another
      day (but remember, we DID recently tighten C code for
      domain names to exclude a leading '.').
      
      * src/conf/storage_conf.c (virStoragePoolSourceFormat)
      (virStoragePoolDefFormat, virStorageVolTargetDefFormat)
      (virStorageVolDefFormat): Escape user-controlled strings.
      (virStorageVolDefParseXML): Parse key, for use in unit tests.
      * src/storage/storage_driver.c (storageVolCreateXML)
      (storageVolCreateXMLFrom): Ensure parsed key doesn't confuse
      volume creation.
      * docs/schemas/basictypes.rng (volName): Relax definition.
      * tests/storagepoolxml2xmltest.c (mymain): Test it.
      * tests/storagevolxml2xmltest.c (mymain): Likewise.
      * tests/storagepoolxml2xmlin/pool-dir-naming.xml: New file.
      * tests/storagepoolxml2xmlout/pool-dir-naming.xml: Likewise.
      * tests/storagevolxml2xmlin/vol-file-naming.xml: Likewise.
      * tests/storagevolxml2xmlout/vol-file-naming.xml: Likewise.
      * tests/storagevolxml2xmlout/vol-*.xml: Fix fallout.
      Signed-off-by: NEric Blake <eblake@redhat.com>
      6cc4d6a3
  23. 14 11月, 2013 1 次提交
    • E
      storage: fix RNG validation of gluster via netfs · 887dd362
      Eric Blake 提交于
      While trying to compare netfs against my new gluster pool, I
      discovered two things:
      
      virt-xml-validate chokes on valid xml produced by 'virsh pool-dumpxml'
      [yet another reason that ALL patches that add new xml should be adding
      corresponding tests]
      
      When using glusterfs FUSE mounts, you cannot access a subdirectory
      of a gluster volume.  The recommended workaround in the gluster
      community is to mount the volume to an intermediate location, then
      bind-mount the desired subdirectory to the final location.  Maybe
      we should teach libvirt to do bind-mounting, but for now I chose to
      just document the limitation.
      
      * docs/storage.html.in: Improve documentation.
      * docs/schemas/storagepool.rng (sourcefmtnetfs): Allow all
      formats, and drop redundant info-vendor.
      * tests/storagepoolxml2xmltest.c (mymain): New test.
      * tests/storagepoolxml2xmlin/pool-netfs-gluster.xml: New file.
      * tests/storagepoolxml2xmlout/pool-netfs-gluster.xml: Likewise.
      Signed-off-by: NEric Blake <eblake@redhat.com>
      887dd362
  24. 08 10月, 2013 1 次提交
  25. 16 7月, 2013 1 次提交
  26. 10 7月, 2013 1 次提交
    • M
      Introduce OOM reporting to virAsprintf · dc6f2dad
      Michal Privoznik 提交于
      Actually, I'm turning this function into a macro as filename,
      function name and line number needs to be passed. The new
      function virAsprintfInternal is introduced with the extended set
      of arguments.
      dc6f2dad
  27. 02 5月, 2013 1 次提交
    • M
      virutil: Move string related functions to virstring.c · 7c9a2d88
      Michal Privoznik 提交于
      The source code base needs to be adapted as well. Some files
      include virutil.h just for the string related functions (here,
      the include is substituted to match the new file), some include
      virutil.h without any need (here, the include is removed), and
      some require both.
      7c9a2d88
  28. 08 4月, 2013 1 次提交
    • O
      New XML attributes for storage pool source adapter · 9f781da6
      Osier Yang 提交于
      This introduces 4 new attributes for storage pool source adapter.
      E.g.
      
      <adapter type='fc_host' parent='scsi_host5' wwnn='20000000c9831b4b' wwpn='10000000c9831b4b'/>
      
      Attribute 'type' can be either 'scsi_host' or 'fc_host', and defaults
      to 'scsi_host' if attribute 'name' is specified. I.e. It's optional
      for 'scsi_host' adapter, for back-compat reason. However, mandatory
      for 'fc_host' adapter and any new future adapter types. Attribute
      'parent' is to specify the parent for the fc_host adapter.
      
      * docs/formatstorage.html.in:
        - Add documents for the 4 new attrs
      * docs/schemas/storagepool.rng:
        - Add RNG schema
      * src/conf/storage_conf.c:
        - Parse and format the new XMLs
      * src/conf/storage_conf.h:
        - New struct virStoragePoolSourceAdapter, replace "char *adapter" with it;
        - New enum virStoragePoolSourceAdapterType
      * src/libvirt_private.syms:
        - Export TypeToString and TypeFromString
      * src/phyp/phyp_driver.c:
        - Replace "adapter" with "adapter.data.name", which is member of the union
          of the new struct virStoragePoolSourceAdapter now. Later patch will
          add the checking, as "adapter.data.name" is only valid for "scsi_host"
          adapter.
      * src/storage/storage_backend_scsi.c:
        - Like above
      * tests/storagepoolxml2xmlin/pool-scsi-type-scsi-host.xml:
      * tests/storagepoolxml2xmlin/pool-scsi-type-fc-host.xml:
        - New test for 'fc_host' and "scsi_host" adapter
      * tests/storagepoolxml2xmlout/pool-scsi.xml:
        - Change the expected output, as the 'type' defaults to 'scsi_host' if 'name"
          specified now
      * tests/storagepoolxml2xmlout/pool-scsi-type-scsi-host.xml:
      * tests/storagepoolxml2xmlout/pool-scsi-type-fc-host.xml:
        - New test
      * tests/storagepoolxml2xmltest.c:
        - Include the test
      9f781da6
  29. 19 7月, 2012 1 次提交
    • S
      Add a sheepdog backend for the storage driver · 29bc4fe6
      Sebastian Wiedenroth 提交于
      This patch brings support to manage sheepdog pools and volumes to libvirt.
      It uses the "collie" command-line utility that comes with sheepdog for that.
      
      A sheepdog pool in libvirt maps to a sheepdog cluster.
      It needs a host and port to connect to, which in most cases
      is just going to be the default of localhost on port 7000.
      
      A sheepdog volume in libvirt maps to a sheepdog vdi.
      To create one specify the pool, a name and the capacity.
      Volumes can also be resized later.
      
      In the volume XML the vdi name has to be put into the <target><path>.
      To use the volume as a disk source for virtual machines specify
      the vdi name as "name" attribute of the <source>.
      The host and port information from the pool are specified inside the host tag.
      
        <disk type='network'>
          ...
          <source protocol="sheepdog" name="vdi_name">
            <host name="localhost" port="7000"/>
          </source>
        </disk>
      
      To work right this patch parses the output of collie,
      so it relies on the raw output option. There recently was a bug which caused
      size information to be reported wrong. This is fixed upstream already and
      will be in the next release.
      Signed-off-by: NSebastian Wiedenroth <wiedi@frubar.net>
      29bc4fe6
  30. 27 3月, 2012 1 次提交
    • M
      Cleanup for a return statement in source files · 9943276f
      Martin Kletzander 提交于
      Return statements with parameter enclosed in parentheses were modified
      and parentheses were removed. The whole change was scripted, here is how:
      
      List of files was obtained using this command:
      git grep -l -e '\<return\s*([^()]*\(([^()]*)[^()]*\)*)\s*;' |             \
      grep -e '\.[ch]$' -e '\.py$'
      
      Found files were modified with this command:
      sed -i -e                                                                 \
      's_^\(.*\<return\)\s*(\(\([^()]*([^()]*)[^()]*\)*\))\s*\(;.*$\)_\1 \2\4_' \
      -e 's_^\(.*\<return\)\s*(\([^()]*\))\s*\(;.*$\)_\1 \2\3_'
      
      Then checked for nonsense.
      
      The whole command looks like this:
      git grep -l -e '\<return\s*([^()]*\(([^()]*)[^()]*\)*)\s*;' |             \
      grep -e '\.[ch]$' -e '\.py$' | xargs sed -i -e                            \
      's_^\(.*\<return\)\s*(\(\([^()]*([^()]*)[^()]*\)*\))\s*\(;.*$\)_\1 \2\4_' \
      -e 's_^\(.*\<return\)\s*(\([^()]*\))\s*\(;.*$\)_\1 \2\3_'
      9943276f
  31. 04 2月, 2012 1 次提交
    • E
      build: expand rule to cover testsuite · 8fe454ce
      Eric Blake 提交于
      The bulk of this patch was done with:
      
      sed -i 's/\(\bfree *(/VIR_FREE(/g' tests/*.c
      
      followed by fixing the few compile errors that resulted.
      
      * cfg.mk (exclude_file_name_regexp--sc_prohibit_raw_allocation):
      Remove tests from exemption.
      * tests/testutils.h: Add common header.
      * tests/commandhelper.c: Fix offenders.
      * tests/cputest.c: Likewise.
      * tests/domainsnapshotxml2xmltest.c: Likewise.
      * tests/interfacexml2xmltest.c: Likewise.
      * tests/networkxml2argvtest.c: Likewise.
      * tests/networkxml2xmltest.c: Likewise.
      * tests/nodedevxml2xmltest.c: Likewise.
      * tests/nodeinfotest.c: Likewise.
      * tests/nwfilterxml2xmltest.c: Likewise.
      * tests/qemuargv2xmltest.c: Likewise.
      * tests/qemuxml2argvtest.c: Likewise.
      * tests/qemuxml2xmltest.c: Likewise.
      * tests/qemuxmlnstest.c: Likewise.
      * tests/qparamtest.c: Likewise.
      * tests/sexpr2xmltest.c: Likewise.
      * tests/storagepoolxml2xmltest.c: Likewise.
      * tests/storagevolxml2xmltest.c: Likewise.
      * tests/testutils.c: Likewise.
      * tests/virshtest.c: Likewise.
      * tests/xencapstest.c: Likewise.
      * tests/xmconfigtest.c: Likewise.
      * tests/xml2sexprtest.c: Likewise.
      8fe454ce
  32. 01 5月, 2011 1 次提交
    • M
      tests: Lower stack usage below 4096 bytes · 9ba4eb3c
      Matthias Bolte 提交于
      Make virtTestLoadFile allocate the buffer to read the file into.
      
      Fix logic error in virtTestLoadFile, stop reading on the first empty line.
      
      Use virFileReadLimFD in virtTestCaptureProgramOutput to avoid manual
      buffer handling.
      9ba4eb3c
  33. 30 4月, 2011 1 次提交
    • E
      tests: simplify common setup · 20986e58
      Eric Blake 提交于
      A few of the tests were missing basic sanity checks, while most
      of them were doing copy-and-paste initialization (in fact, some
      of them pasted the argc > 1 check more than once!).  It's much
      nicer to do things in one common place, and minimizes the size of
      the next patch that fixes getcwd usage.
      
      * tests/testutils.h (EXIT_AM_HARDFAIL): New define.
      (progname, abs_srcdir): Define for all tests.
      (VIRT_TEST_MAIN): Change callback signature.
      * tests/testutils.c (virtTestMain): Do more common init.
      * tests/commandtest.c (mymain): Simplify.
      * tests/cputest.c (mymain): Likewise.
      * tests/esxutilstest.c (mymain): Likewise.
      * tests/eventtest.c (mymain): Likewise.
      * tests/hashtest.c (mymain): Likewise.
      * tests/networkxml2xmltest.c (mymain): Likewise.
      * tests/nodedevxml2xmltest.c (myname): Likewise.
      * tests/nodeinfotest.c (mymain): Likewise.
      * tests/nwfilterxml2xmltest.c (mymain): Likewise.
      * tests/qemuargv2xmltest.c (mymain): Likewise.
      * tests/qemuhelptest.c (mymain): Likewise.
      * tests/qemuxml2argvtest.c (mymain): Likewise.
      * tests/qemuxml2xmltest.c (mymain): Likewise.
      * tests/qparamtest.c (mymain): Likewise.
      * tests/sexpr2xmltest.c (mymain): Likewise.
      * tests/sockettest.c (mymain): Likewise.
      * tests/statstest.c (mymain): Likewise.
      * tests/storagepoolxml2xmltest.c (mymain): Likewise.
      * tests/storagevolxml2xmltest.c (mymain): Likewise.
      * tests/virbuftest.c (mymain): Likewise.
      * tests/virshtest.c (mymain): Likewise.
      * tests/vmx2xmltest.c (mymain): Likewise.
      * tests/xencapstest.c (mymain): Likewise.
      * tests/xmconfigtest.c (mymain): Likewise.
      * tests/xml2sexprtest.c (mymain): Likewise.
      * tests/xml2vmxtest.c (mymain): Likewise.
      20986e58
  34. 20 8月, 2010 1 次提交
    • P
      storage: add support for Vendor and Model in XML · 20be699e
      Patrick Dignan 提交于
      I wrote a patch to add support for listing the Vendor and Model of a
      storage pool in the storage pool XML.  This would allow vendor
      extensions of specific devices.  The patch includes a test for the new
      attributes as well.
      
      Patrick Dignan
      20be699e
  35. 09 6月, 2010 1 次提交
  36. 10 2月, 2010 1 次提交
    • D
      Remove virConnectPtr from storage APIs & driver · 03136638
      Daniel P. Berrange 提交于
      The virConnectPtr is no longer required for error reporting since
      that is recorded in a thread local. Remove use of virConnectPtr
      from all APIs in storage_conf.{h,c} and storage_encryption_conf.{h,c}
      and update all callers to match
      03136638