Generic Thermal Sysfs driver How To
2
===================================
Z
Zhang Rui 已提交
3 4 5 6 7 8 9 10 11 12

Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>

Updated: 2 January 2008

Copyright (c)  2008 Intel Corporation


0. Introduction

13 14 15
The generic thermal sysfs provides a set of interfaces for thermal zone
devices (sensors) and thermal cooling devices (fan, processor...) to register
with the thermal management solution and to be a part of it.
Z
Zhang Rui 已提交
16

17 18 19 20
This how-to focuses on enabling new thermal zone and cooling devices to
participate in thermal management.
This solution is platform independent and any type of thermal zone devices
and cooling devices should be able to make use of the infrastructure.
Z
Zhang Rui 已提交
21

22 23 24 25 26
The main task of the thermal sysfs driver is to expose thermal zone attributes
as well as cooling device attributes to the user space.
An intelligent thermal management application can make decisions based on
inputs from thermal zone attributes (the current temperature and trip point
temperature) and throttle appropriate devices.
Z
Zhang Rui 已提交
27 28 29 30 31 32 33

[0-*]	denotes any positive number starting from 0
[1-*]	denotes any positive number starting from 1

1. thermal sysfs driver interface functions

1.1 thermal zone device interface
34
1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
35
		int trips, int mask, void *devdata,
36 37 38
		struct thermal_zone_device_ops *ops,
		const struct thermal_zone_params *tzp,
		int passive_delay, int polling_delay))
39 40 41 42 43

    This interface function adds a new thermal zone device (sensor) to
    /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
    thermal cooling devices registered at the same time.

44
    type: the thermal zone type.
45
    trips: the total number of trip points this thermal zone supports.
46
    mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
47 48 49 50 51
    devdata: device private data
    ops: thermal zone device call-backs.
	.bind: bind the thermal zone device with a thermal cooling device.
	.unbind: unbind the thermal zone device with a thermal cooling device.
	.get_temp: get the current temperature of the thermal zone.
52 53 54
	.set_trips: set the trip points window. Whenever the current temperature
		    is updated, the trip points immediately below and above the
		    current temperature are found.
Z
Zhang Rui 已提交
55 56 57
	.get_mode: get the current mode (enabled/disabled) of the thermal zone.
	    - "enabled" means the kernel thermal management is enabled.
	    - "disabled" will prevent kernel thermal driver action upon trip points
58
	      so that user applications can take charge of thermal management.
Z
Zhang Rui 已提交
59
	.set_mode: set the mode (enabled/disabled) of the thermal zone.
60 61 62
	.get_trip_type: get the type of certain trip point.
	.get_trip_temp: get the temperature above which the certain trip point
			will be fired.
63 64
	.set_emul_temp: set the emulation temperature which helps in debugging
			different threshold temperature points.
65 66 67 68 69 70
    tzp: thermal zone platform parameters.
    passive_delay: number of milliseconds to wait between polls when
	performing passive cooling.
    polling_delay: number of milliseconds to wait between polls when checking
	whether trip points have been crossed (0 for interrupt driven systems).

Z
Zhang Rui 已提交
71 72 73

1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)

74
    This interface function removes the thermal zone device.
75 76
    It deletes the corresponding entry from /sys/class/thermal folder and
    unbinds all the thermal cooling devices it uses.
Z
Zhang Rui 已提交
77

78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100
1.1.3 struct thermal_zone_device *thermal_zone_of_sensor_register(
		struct device *dev, int sensor_id, void *data,
		const struct thermal_zone_of_device_ops *ops)

	This interface adds a new sensor to a DT thermal zone.
	This function will search the list of thermal zones described in
	device tree and look for the zone that refer to the sensor device
	pointed by dev->of_node as temperature providers. For the zone
	pointing to the sensor node, the sensor will be added to the DT
	thermal zone device.

	The parameters for this interface are:
	dev:		Device node of sensor containing valid node pointer in
			dev->of_node.
	sensor_id:	a sensor identifier, in case the sensor IP has more
			than one sensors
	data:		a private pointer (owned by the caller) that will be
			passed back, when a temperature reading is needed.
	ops:		struct thermal_zone_of_device_ops *.

			get_temp:	a pointer to a function that reads the
					sensor temperature. This is mandatory
					callback provided by sensor driver.
101 102 103 104
			set_trips:      a pointer to a function that sets a
					temperature window. When this window is
					left the driver must inform the thermal
					core via thermal_zone_device_update.
105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126
			get_trend: 	a pointer to a function that reads the
					sensor temperature trend.
			set_emul_temp:	a pointer to a function that sets
					sensor emulated temperature.
	The thermal zone temperature is provided by the get_temp() function
	pointer of thermal_zone_of_device_ops. When called, it will
	have the private pointer @data back.

	It returns error pointer if fails otherwise valid thermal zone device
	handle. Caller should check the return handle with IS_ERR() for finding
	whether success or not.

1.1.4 void thermal_zone_of_sensor_unregister(struct device *dev,
		struct thermal_zone_device *tzd)

	This interface unregisters a sensor from a DT thermal zone which was
	successfully added by interface thermal_zone_of_sensor_register().
	This function removes the sensor callbacks and private data from the
	thermal zone device registered with thermal_zone_of_sensor_register()
	interface. It will also silent the zone by remove the .get_temp() and
	get_trend() thermal zone device callbacks.

127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149
1.1.5 struct thermal_zone_device *devm_thermal_zone_of_sensor_register(
		struct device *dev, int sensor_id,
		void *data, const struct thermal_zone_of_device_ops *ops)

	This interface is resource managed version of
	thermal_zone_of_sensor_register().
	All details of thermal_zone_of_sensor_register() described in
	section 1.1.3 is applicable here.
	The benefit of using this interface to register sensor is that it
	is not require to explicitly call thermal_zone_of_sensor_unregister()
	in error path or during driver unbinding as this is done by driver
	resource manager.

1.1.6 void devm_thermal_zone_of_sensor_unregister(struct device *dev,
		struct thermal_zone_device *tzd)

	This interface is resource managed version of
	thermal_zone_of_sensor_unregister().
	All details of thermal_zone_of_sensor_unregister() described in
	section 1.1.4 is applicable here.
	Normally this function will not need to be called and the resource
	management code will ensure that the resource is freed.

150 151 152 153 154 155 156 157 158 159 160 161
1.1.7 int thermal_zone_get_slope(struct thermal_zone_device *tz)

	This interface is used to read the slope attribute value
	for the thermal zone device, which might be useful for platform
	drivers for temperature calculations.

1.1.8 int thermal_zone_get_offset(struct thermal_zone_device *tz)

	This interface is used to read the offset attribute value
	for the thermal zone device, which might be useful for platform
	drivers for temperature calculations.

Z
Zhang Rui 已提交
162 163
1.2 thermal cooling device interface
1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
164 165 166 167
		void *devdata, struct thermal_cooling_device_ops *)

    This interface function adds a new thermal cooling device (fan/processor/...)
    to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
168
    to all the thermal zone devices registered at the same time.
169 170 171 172
    name: the cooling device name.
    devdata: device private data.
    ops: thermal cooling devices call-backs.
	.get_max_state: get the Maximum throttle state of the cooling device.
173
	.get_cur_state: get the Currently requested throttle state of the cooling device.
174
	.set_cur_state: set the Current throttle state of the cooling device.
Z
Zhang Rui 已提交
175 176 177

1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)

178 179 180
    This interface function removes the thermal cooling device.
    It deletes the corresponding entry from /sys/class/thermal folder and
    unbinds itself from all the thermal zone devices using it.
Z
Zhang Rui 已提交
181 182 183

1.3 interface for binding a thermal zone device with a thermal cooling device
1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
Z
Zhang Rui 已提交
184
	int trip, struct thermal_cooling_device *cdev,
185
	unsigned long upper, unsigned long lower, unsigned int weight);
Z
Zhang Rui 已提交
186

187
    This interface function binds a thermal cooling device to a particular trip
188 189 190 191
    point of a thermal zone device.
    This function is usually called in the thermal zone device .bind callback.
    tz: the thermal zone device
    cdev: thermal cooling device
192 193
    trip: indicates which trip point in this thermal zone the cooling device
          is associated with.
Z
Zhang Rui 已提交
194 195 196 197 198 199
    upper:the Maximum cooling state for this trip point.
          THERMAL_NO_LIMIT means no upper limit,
	  and the cooling device can be in max_state.
    lower:the Minimum cooling state can be used for this trip point.
          THERMAL_NO_LIMIT means no lower limit,
	  and the cooling device can be in cooling state 0.
200 201
    weight: the influence of this cooling device in this thermal
            zone.  See 1.4.1 below for more information.
Z
Zhang Rui 已提交
202 203

1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
204
		int trip, struct thermal_cooling_device *cdev);
Z
Zhang Rui 已提交
205

206
    This interface function unbinds a thermal cooling device from a particular
207 208 209 210
    trip point of a thermal zone device. This function is usually called in
    the thermal zone device .unbind callback.
    tz: the thermal zone device
    cdev: thermal cooling device
211 212
    trip: indicates which trip point in this thermal zone the cooling device
          is associated with.
Z
Zhang Rui 已提交
213

214 215 216 217 218
1.4 Thermal Zone Parameters
1.4.1 struct thermal_bind_params
    This structure defines the following parameters that are used to bind
    a zone with a cooling device for a particular trip point.
    .cdev: The cooling device pointer
219 220 221 222 223 224 225 226 227
    .weight: The 'influence' of a particular cooling device on this
             zone. This is relative to the rest of the cooling
             devices. For example, if all cooling devices have a
             weight of 1, then they all contribute the same. You can
             use percentages if you want, but it's not mandatory. A
             weight of 0 means that this cooling device doesn't
             contribute to the cooling of this zone unless all cooling
             devices have a weight of 0. If all weights are 0, then
             they all contribute the same.
228 229 230 231
    .trip_mask:This is a bit mask that gives the binding relation between
               this thermal zone and cdev, for a particular trip point.
               If nth bit is set, then the cdev and thermal zone are bound
               for trip point n.
232 233 234 235 236 237 238
    .binding_limits: This is an array of cooling state limits. Must have
                     exactly 2 * thermal_zone.number_of_trip_points. It is an
                     array consisting of tuples <lower-state upper-state> of
                     state limits. Each trip will be associated with one state
                     limit tuple when binding. A NULL pointer means
                     <THERMAL_NO_LIMITS THERMAL_NO_LIMITS> on all trips.
                     These limits are used when binding a cdev to a trip point.
239 240 241 242 243 244 245 246
    .match: This call back returns success(0) if the 'tz and cdev' need to
	    be bound, as per platform data.
1.4.2 struct thermal_zone_params
    This structure defines the platform level parameters for a thermal zone.
    This data, for each thermal zone should come from the platform layer.
    This is an optional feature where some platforms can choose not to
    provide this data.
    .governor_name: Name of the thermal governor used for this zone
247 248 249 250 251
    .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
               is required. when no_hwmon == false, a hwmon sysfs interface
               will be created. when no_hwmon == true, nothing will be done.
               In case the thermal_zone_params is NULL, the hwmon interface
               will be created (for backward compatibility).
252 253 254
    .num_tbps: Number of thermal_bind_params entries for this zone
    .tbp: thermal_bind_params entries

Z
Zhang Rui 已提交
255 256 257
2. sysfs attributes structure

RO	read only value
258
WO	write only value
Z
Zhang Rui 已提交
259 260
RW	read/write value

Z
Zhang Rui 已提交
261 262 263
Thermal sysfs attributes will be represented under /sys/class/thermal.
Hwmon sysfs I/F extension is also available under /sys/class/hwmon
if hwmon is compiled in or built as a module.
Z
Zhang Rui 已提交
264 265

Thermal zone device sys I/F, created once it's registered:
Z
Zhang Rui 已提交
266
/sys/class/thermal/thermal_zone[0-*]:
267 268 269
    |---type:			Type of the thermal zone
    |---temp:			Current temperature
    |---mode:			Working mode of the thermal zone
270
    |---policy:			Thermal governor used for this zone
271
    |---available_policies:	Available thermal governors for this zone
272 273
    |---trip_point_[0-*]_temp:	Trip point temperature
    |---trip_point_[0-*]_type:	Trip point type
D
Durgadoss R 已提交
274
    |---trip_point_[0-*]_hyst:	Hysteresis value for this trip point
275
    |---emul_temp:		Emulated temperature set node
276 277 278 279 280 281
    |---sustainable_power:      Sustainable dissipatable power
    |---k_po:                   Proportional term during temperature overshoot
    |---k_pu:                   Proportional term during temperature undershoot
    |---k_i:                    PID's integral term in the power allocator gov
    |---k_d:                    PID's derivative term in the power allocator
    |---integral_cutoff:        Offset above which errors are accumulated
282 283
    |---slope:                  Slope constant applied as linear extrapolation
    |---offset:                 Offset constant applied as linear extrapolation
Z
Zhang Rui 已提交
284 285

Thermal cooling device sys I/F, created once it's registered:
Z
Zhang Rui 已提交
286
/sys/class/thermal/cooling_device[0-*]:
287 288 289
    |---type:			Type of the cooling device(processor/fan/...)
    |---max_state:		Maximum cooling state of the cooling device
    |---cur_state:		Current cooling state of the cooling device
290 291 292 293 294
    |---stats:			Directory containing cooling device's statistics
    |---stats/reset:		Writing any value resets the statistics
    |---stats/time_in_state_ms:	Time (msec) spent in various cooling states
    |---stats/total_trans:	Total number of times cooling state is changed
    |---stats/trans_table:	Cooing state transition table
Z
Zhang Rui 已提交
295 296


297 298 299 300
Then next two dynamic attributes are created/removed in pairs. They represent
the relationship between a thermal zone and its associated cooling device.
They are created/removed for each successful execution of
thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
Z
Zhang Rui 已提交
301

302 303 304
/sys/class/thermal/thermal_zone[0-*]:
    |---cdev[0-*]:		[0-*]th cooling device in current thermal zone
    |---cdev[0-*]_trip_point:	Trip point that cdev[0-*] is associated with
J
Javi Merino 已提交
305 306
    |---cdev[0-*]_weight:       Influence of the cooling device in
                                this thermal zone
Z
Zhang Rui 已提交
307

Z
Zhang Rui 已提交
308
Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
309 310 311 312 313
the generic thermal driver also creates a hwmon sysfs I/F for each _type_
of thermal zone device. E.g. the generic thermal driver registers one hwmon
class device and build the associated hwmon sysfs I/F for all the registered
ACPI thermal zones.

Z
Zhang Rui 已提交
314
/sys/class/hwmon/hwmon[0-*]:
315 316 317 318
    |---name:			The type of the thermal zone devices
    |---temp[1-*]_input:	The current temperature of thermal zone [1-*]
    |---temp[1-*]_critical:	The critical trip point of thermal zone [1-*]

319
Please read Documentation/hwmon/sysfs-interface.rst for additional information.
Z
Zhang Rui 已提交
320 321 322 323 324

***************************
* Thermal zone attributes *
***************************

325 326 327 328 329 330 331 332 333 334 335 336 337 338
type
	Strings which represent the thermal zone type.
	This is given by thermal zone driver as part of registration.
	E.g: "acpitz" indicates it's an ACPI thermal device.
	In order to keep it consistent with hwmon sys attribute; this should
	be a short, lowercase string, not containing spaces nor dashes.
	RO, Required

temp
	Current temperature as reported by thermal zone (sensor).
	Unit: millidegree Celsius
	RO, Required

mode
Z
Zhang Rui 已提交
339
	One of the predefined values in [enabled, disabled].
340 341 342
	This file gives information about the algorithm that is currently
	managing the thermal zone. It can be either default kernel based
	algorithm or user space application.
Z
Zhang Rui 已提交
343 344 345 346
	enabled		= enable Kernel Thermal management.
	disabled	= Preventing kernel thermal zone driver actions upon
			  trip points so that user application can take full
			  charge of the thermal management.
347 348
	RW, Optional

349 350 351 352
policy
	One of the various thermal governors used for a particular zone.
	RW, Required

353 354 355 356
available_policies
	Available thermal governors which can be used for a particular zone.
	RO, Required

357 358 359 360 361 362 363 364 365 366 367
trip_point_[0-*]_temp
	The temperature above which trip point will be fired.
	Unit: millidegree Celsius
	RO, Optional

trip_point_[0-*]_type
	Strings which indicate the type of the trip point.
	E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
	thermal zone.
	RO, Optional

D
Durgadoss R 已提交
368 369 370 371 372
trip_point_[0-*]_hyst
	The hysteresis value for a trip point, represented as an integer
	Unit: Celsius
	RW, Optional

373 374 375 376 377 378
cdev[0-*]
	Sysfs link to the thermal cooling device node where the sys I/F
	for cooling device throttling control represents.
	RO, Optional

cdev[0-*]_trip_point
379 380
	The trip point in this thermal zone which cdev[0-*] is associated
	with; -1 means the cooling device is not associated with any trip
381 382
	point.
	RO, Optional
383

J
Javi Merino 已提交
384 385 386 387 388 389 390 391
cdev[0-*]_weight
        The influence of cdev[0-*] in this thermal zone. This value
        is relative to the rest of cooling devices in the thermal
        zone. For example, if a cooling device has a weight double
        than that of other, it's twice as effective in cooling the
        thermal zone.
        RW, Optional

392 393 394 395 396 397 398
passive
	Attribute is only present for zones in which the passive cooling
	policy is not supported by native thermal driver. Default is zero
	and can be set to a temperature (in millidegrees) to enable a
	passive trip point for the zone. Activation is done by polling with
	an interval of 1 second.
	Unit: millidegrees Celsius
399
	Valid values: 0 (disabled) or greater than 1000
400
	RW, Optional
401

402 403 404 405 406 407 408 409 410 411
emul_temp
	Interface to set the emulated temperature method in thermal zone
	(sensor). After setting this temperature, the thermal zone may pass
	this temperature to platform emulation function if registered or
	cache it locally. This is useful in debugging different temperature
	threshold and its associated cooling action. This is write only node
	and writing 0 on this node should disable emulation.
	Unit: millidegree Celsius
	WO, Optional

412 413 414 415
	  WARNING: Be careful while enabling this option on production systems,
	  because userland can easily disable the thermal policy by simply
	  flooding this sysfs node with low temperature values.

416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459
sustainable_power
	An estimate of the sustained power that can be dissipated by
	the thermal zone. Used by the power allocator governor. For
	more information see Documentation/thermal/power_allocator.txt
	Unit: milliwatts
	RW, Optional

k_po
	The proportional term of the power allocator governor's PID
	controller during temperature overshoot. Temperature overshoot
	is when the current temperature is above the "desired
	temperature" trip point. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

k_pu
	The proportional term of the power allocator governor's PID
	controller during temperature undershoot. Temperature undershoot
	is when the current temperature is below the "desired
	temperature" trip point. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

k_i
	The integral term of the power allocator governor's PID
	controller. This term allows the PID controller to compensate
	for long term drift. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

k_d
	The derivative term of the power allocator governor's PID
	controller. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

integral_cutoff
	Temperature offset from the desired temperature trip point
	above which the integral term of the power allocator
	governor's PID controller starts accumulating errors. For
	example, if integral_cutoff is 0, then the integral term only
	accumulates error when temperature is above the desired
	temperature trip point. For more information see
	Documentation/thermal/power_allocator.txt
460
	Unit: millidegree Celsius
461 462
	RW, Optional

463 464 465 466 467 468 469 470 471 472 473 474 475 476
slope
	The slope constant used in a linear extrapolation model
	to determine a hotspot temperature based off the sensor's
	raw readings. It is up to the device driver to determine
	the usage of these values.
	RW, Optional

offset
	The offset constant used in a linear extrapolation model
	to determine a hotspot temperature based off the sensor's
	raw readings. It is up to the device driver to determine
	the usage of these values.
	RW, Optional

477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497
*****************************
* Cooling device attributes *
*****************************

type
	String which represents the type of device, e.g:
	- for generic ACPI: should be "Fan", "Processor" or "LCD"
	- for memory controller device on intel_menlow platform:
	  should be "Memory controller".
	RO, Required

max_state
	The maximum permissible cooling state of this cooling device.
	RO, Required

cur_state
	The current cooling state of this cooling device.
	The value can any integer numbers between 0 and max_state:
	- cur_state == 0 means no cooling
	- cur_state == max_state means the maximum cooling.
	RW, Required
Z
Zhang Rui 已提交
498

499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523
stats/reset
	Writing any value resets the cooling device's statistics.
	WO, Required

stats/time_in_state_ms:
	The amount of time spent by the cooling device in various cooling
	states. The output will have "<state> <time>" pair in each line, which
	will mean this cooling device spent <time> msec of time at <state>.
	Output will have one line for each of the supported states.  usertime
	units here is 10mS (similar to other time exported in /proc).
	RO, Required

stats/total_trans:
	A single positive value showing the total number of times the state of a
	cooling device is changed.
	RO, Required

stats/trans_table:
	This gives fine grained information about all the cooling state
	transitions. The cat output here is a two dimensional matrix, where an
	entry <i,j> (row i, column j) represents the number of transitions from
	State_i to State_j. If the transition table is bigger than PAGE_SIZE,
	reading this will return an -EFBIG error.
	RO, Required

Z
Zhang Rui 已提交
524 525
3. A simple implementation

526 527 528 529 530
ACPI thermal zone may support multiple trip points like critical, hot,
passive, active. If an ACPI thermal zone supports critical, passive,
active[0] and active[1] at the same time, it may register itself as a
thermal_zone_device (thermal_zone1) with 4 trip points in all.
It has one processor and one fan, which are both registered as
J
Javi Merino 已提交
531 532
thermal_cooling_device. Both are considered to have the same
effectiveness in cooling the thermal zone.
533 534 535

If the processor is listed in _PSL method, and the fan is listed in _AL0
method, the sys I/F structure will be built like this:
Z
Zhang Rui 已提交
536 537 538 539

/sys/class/thermal:

|thermal_zone1:
540 541
    |---type:			acpitz
    |---temp:			37000
Z
Zhang Rui 已提交
542
    |---mode:			enabled
543
    |---policy:			step_wise
544
    |---available_policies:	step_wise fair_share
545 546 547 548 549 550 551 552 553 554
    |---trip_point_0_temp:	100000
    |---trip_point_0_type:	critical
    |---trip_point_1_temp:	80000
    |---trip_point_1_type:	passive
    |---trip_point_2_temp:	70000
    |---trip_point_2_type:	active0
    |---trip_point_3_temp:	60000
    |---trip_point_3_type:	active1
    |---cdev0:			--->/sys/class/thermal/cooling_device0
    |---cdev0_trip_point:	1	/* cdev0 can be used for passive */
J
Javi Merino 已提交
555
    |---cdev0_weight:           1024
556 557
    |---cdev1:			--->/sys/class/thermal/cooling_device3
    |---cdev1_trip_point:	2	/* cdev1 can be used for active[0]*/
J
Javi Merino 已提交
558
    |---cdev1_weight:           1024
Z
Zhang Rui 已提交
559 560

|cooling_device0:
561 562 563
    |---type:			Processor
    |---max_state:		8
    |---cur_state:		0
Z
Zhang Rui 已提交
564 565

|cooling_device3:
566 567 568
    |---type:			Fan
    |---max_state:		2
    |---cur_state:		0
Z
Zhang Rui 已提交
569 570 571 572

/sys/class/hwmon:

|hwmon0:
573 574 575
    |---name:			acpitz
    |---temp1_input:		37000
    |---temp1_crit:		100000
576 577 578 579 580 581

4. Event Notification

The framework includes a simple notification mechanism, in the form of a
netlink event. Netlink socket initialization is done during the _init_
of the framework. Drivers which intend to use the notification mechanism
582
just need to call thermal_generate_netlink_event() with two arguments viz
583 584 585
(originator, event). The originator is a pointer to struct thermal_zone_device
from where the event has been originated. An integer which represents the
thermal zone device will be used in the message to identify the zone. The
586 587 588
event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
crosses any of the configured thresholds.
589 590 591 592 593 594 595 596 597 598 599 600 601 602 603

5. Export Symbol APIs:

5.1: get_tz_trend:
This function returns the trend of a thermal zone, i.e the rate of change
of temperature of the thermal zone. Ideally, the thermal sensor drivers
are supposed to implement the callback. If they don't, the thermal
framework calculated the trend by comparing the previous and the current
temperature values.

5.2:get_thermal_instance:
This function returns the thermal_instance corresponding to a given
{thermal_zone, cooling_device, trip_point} combination. Returns NULL
if such an instance does not exist.

604
5.3:thermal_notify_framework:
605 606 607 608 609 610 611 612 613 614 615
This function handles the trip events from sensor drivers. It starts
throttling the cooling devices according to the policy configured.
For CRITICAL and HOT trip points, this notifies the respective drivers,
and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
The throttling policy is based on the configured platform data; if no
platform data is provided, this uses the step_wise throttling policy.

5.4:thermal_cdev_update:
This function serves as an arbitrator to set the state of a cooling
device. It sets the cooling device to the deepest cooling state if
possible.
616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636

6. thermal_emergency_poweroff:

On an event of critical trip temperature crossing. Thermal framework
allows the system to shutdown gracefully by calling orderly_poweroff().
In the event of a failure of orderly_poweroff() to shut down the system
we are in danger of keeping the system alive at undesirably high
temperatures. To mitigate this high risk scenario we program a work
queue to fire after a pre-determined number of seconds to start
an emergency shutdown of the device using the kernel_power_off()
function. In case kernel_power_off() fails then finally
emergency_restart() is called in the worst case.

The delay should be carefully profiled so as to give adequate time for
orderly_poweroff(). In case of failure of an orderly_poweroff() the
emergency poweroff kicks in after the delay has elapsed and shuts down
the system.

If set to 0 emergency poweroff will not be supported. So a carefully
profiled non-zero positive value is a must for emergerncy poweroff to be
triggered.