sysfs-api.txt 19.4 KB
Newer Older
Z
Zhang Rui 已提交
1
Generic Thermal Sysfs driver How To
2
===================================
Z
Zhang Rui 已提交
3 4 5 6 7 8 9 10 11 12

Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>

Updated: 2 January 2008

Copyright (c)  2008 Intel Corporation


0. Introduction

13 14 15
The generic thermal sysfs provides a set of interfaces for thermal zone
devices (sensors) and thermal cooling devices (fan, processor...) to register
with the thermal management solution and to be a part of it.
Z
Zhang Rui 已提交
16

17 18 19 20
This how-to focuses on enabling new thermal zone and cooling devices to
participate in thermal management.
This solution is platform independent and any type of thermal zone devices
and cooling devices should be able to make use of the infrastructure.
Z
Zhang Rui 已提交
21

22 23 24 25 26
The main task of the thermal sysfs driver is to expose thermal zone attributes
as well as cooling device attributes to the user space.
An intelligent thermal management application can make decisions based on
inputs from thermal zone attributes (the current temperature and trip point
temperature) and throttle appropriate devices.
Z
Zhang Rui 已提交
27 28 29 30 31 32 33

[0-*]	denotes any positive number starting from 0
[1-*]	denotes any positive number starting from 1

1. thermal sysfs driver interface functions

1.1 thermal zone device interface
34
1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
35
		int trips, int mask, void *devdata,
36 37 38
		struct thermal_zone_device_ops *ops,
		const struct thermal_zone_params *tzp,
		int passive_delay, int polling_delay))
39 40 41 42 43

    This interface function adds a new thermal zone device (sensor) to
    /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
    thermal cooling devices registered at the same time.

44
    type: the thermal zone type.
45
    trips: the total number of trip points this thermal zone supports.
46
    mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
47 48 49 50 51
    devdata: device private data
    ops: thermal zone device call-backs.
	.bind: bind the thermal zone device with a thermal cooling device.
	.unbind: unbind the thermal zone device with a thermal cooling device.
	.get_temp: get the current temperature of the thermal zone.
Z
Zhang Rui 已提交
52 53 54
	.get_mode: get the current mode (enabled/disabled) of the thermal zone.
	    - "enabled" means the kernel thermal management is enabled.
	    - "disabled" will prevent kernel thermal driver action upon trip points
55
	      so that user applications can take charge of thermal management.
Z
Zhang Rui 已提交
56
	.set_mode: set the mode (enabled/disabled) of the thermal zone.
57 58 59
	.get_trip_type: get the type of certain trip point.
	.get_trip_temp: get the temperature above which the certain trip point
			will be fired.
60 61
	.set_emul_temp: set the emulation temperature which helps in debugging
			different threshold temperature points.
62 63 64 65 66 67
    tzp: thermal zone platform parameters.
    passive_delay: number of milliseconds to wait between polls when
	performing passive cooling.
    polling_delay: number of milliseconds to wait between polls when checking
	whether trip points have been crossed (0 for interrupt driven systems).

Z
Zhang Rui 已提交
68 69 70

1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)

71 72 73
    This interface function removes the thermal zone device.
    It deletes the corresponding entry form /sys/class/thermal folder and
    unbind all the thermal cooling devices it uses.
Z
Zhang Rui 已提交
74 75 76

1.2 thermal cooling device interface
1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
77 78 79 80 81 82 83 84 85 86 87
		void *devdata, struct thermal_cooling_device_ops *)

    This interface function adds a new thermal cooling device (fan/processor/...)
    to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
    to all the thermal zone devices register at the same time.
    name: the cooling device name.
    devdata: device private data.
    ops: thermal cooling devices call-backs.
	.get_max_state: get the Maximum throttle state of the cooling device.
	.get_cur_state: get the Current throttle state of the cooling device.
	.set_cur_state: set the Current throttle state of the cooling device.
Z
Zhang Rui 已提交
88 89 90

1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)

91 92 93
    This interface function remove the thermal cooling device.
    It deletes the corresponding entry form /sys/class/thermal folder and
    unbind itself from all the thermal zone devices using it.
Z
Zhang Rui 已提交
94 95 96

1.3 interface for binding a thermal zone device with a thermal cooling device
1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
Z
Zhang Rui 已提交
97
	int trip, struct thermal_cooling_device *cdev,
98
	unsigned long upper, unsigned long lower, unsigned int weight);
Z
Zhang Rui 已提交
99

100 101 102 103 104 105 106
    This interface function bind a thermal cooling device to the certain trip
    point of a thermal zone device.
    This function is usually called in the thermal zone device .bind callback.
    tz: the thermal zone device
    cdev: thermal cooling device
    trip: indicates which trip point the cooling devices is associated with
	  in this thermal zone.
Z
Zhang Rui 已提交
107 108 109 110 111 112
    upper:the Maximum cooling state for this trip point.
          THERMAL_NO_LIMIT means no upper limit,
	  and the cooling device can be in max_state.
    lower:the Minimum cooling state can be used for this trip point.
          THERMAL_NO_LIMIT means no lower limit,
	  and the cooling device can be in cooling state 0.
113 114
    weight: the influence of this cooling device in this thermal
            zone.  See 1.4.1 below for more information.
Z
Zhang Rui 已提交
115 116

1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
117
		int trip, struct thermal_cooling_device *cdev);
Z
Zhang Rui 已提交
118

119 120 121 122 123 124 125
    This interface function unbind a thermal cooling device from the certain
    trip point of a thermal zone device. This function is usually called in
    the thermal zone device .unbind callback.
    tz: the thermal zone device
    cdev: thermal cooling device
    trip: indicates which trip point the cooling devices is associated with
	  in this thermal zone.
Z
Zhang Rui 已提交
126

127 128 129 130 131
1.4 Thermal Zone Parameters
1.4.1 struct thermal_bind_params
    This structure defines the following parameters that are used to bind
    a zone with a cooling device for a particular trip point.
    .cdev: The cooling device pointer
132 133 134 135 136 137 138 139 140
    .weight: The 'influence' of a particular cooling device on this
             zone. This is relative to the rest of the cooling
             devices. For example, if all cooling devices have a
             weight of 1, then they all contribute the same. You can
             use percentages if you want, but it's not mandatory. A
             weight of 0 means that this cooling device doesn't
             contribute to the cooling of this zone unless all cooling
             devices have a weight of 0. If all weights are 0, then
             they all contribute the same.
141 142 143 144
    .trip_mask:This is a bit mask that gives the binding relation between
               this thermal zone and cdev, for a particular trip point.
               If nth bit is set, then the cdev and thermal zone are bound
               for trip point n.
145 146 147 148 149 150 151
    .limits: This is an array of cooling state limits. Must have exactly
         2 * thermal_zone.number_of_trip_points. It is an array consisting
         of tuples <lower-state upper-state> of state limits. Each trip
         will be associated with one state limit tuple when binding.
         A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
         on all trips. These limits are used when binding a cdev to a
         trip point.
152 153 154 155 156 157 158 159
    .match: This call back returns success(0) if the 'tz and cdev' need to
	    be bound, as per platform data.
1.4.2 struct thermal_zone_params
    This structure defines the platform level parameters for a thermal zone.
    This data, for each thermal zone should come from the platform layer.
    This is an optional feature where some platforms can choose not to
    provide this data.
    .governor_name: Name of the thermal governor used for this zone
160 161 162 163 164
    .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
               is required. when no_hwmon == false, a hwmon sysfs interface
               will be created. when no_hwmon == true, nothing will be done.
               In case the thermal_zone_params is NULL, the hwmon interface
               will be created (for backward compatibility).
165 166 167
    .num_tbps: Number of thermal_bind_params entries for this zone
    .tbp: thermal_bind_params entries

Z
Zhang Rui 已提交
168 169 170 171 172
2. sysfs attributes structure

RO	read only value
RW	read/write value

Z
Zhang Rui 已提交
173 174 175
Thermal sysfs attributes will be represented under /sys/class/thermal.
Hwmon sysfs I/F extension is also available under /sys/class/hwmon
if hwmon is compiled in or built as a module.
Z
Zhang Rui 已提交
176 177

Thermal zone device sys I/F, created once it's registered:
Z
Zhang Rui 已提交
178
/sys/class/thermal/thermal_zone[0-*]:
179 180 181
    |---type:			Type of the thermal zone
    |---temp:			Current temperature
    |---mode:			Working mode of the thermal zone
182
    |---policy:			Thermal governor used for this zone
183 184
    |---trip_point_[0-*]_temp:	Trip point temperature
    |---trip_point_[0-*]_type:	Trip point type
D
Durgadoss R 已提交
185
    |---trip_point_[0-*]_hyst:	Hysteresis value for this trip point
186
    |---emul_temp:		Emulated temperature set node
187 188 189 190 191 192
    |---sustainable_power:      Sustainable dissipatable power
    |---k_po:                   Proportional term during temperature overshoot
    |---k_pu:                   Proportional term during temperature undershoot
    |---k_i:                    PID's integral term in the power allocator gov
    |---k_d:                    PID's derivative term in the power allocator
    |---integral_cutoff:        Offset above which errors are accumulated
Z
Zhang Rui 已提交
193 194

Thermal cooling device sys I/F, created once it's registered:
Z
Zhang Rui 已提交
195
/sys/class/thermal/cooling_device[0-*]:
196 197 198
    |---type:			Type of the cooling device(processor/fan/...)
    |---max_state:		Maximum cooling state of the cooling device
    |---cur_state:		Current cooling state of the cooling device
Z
Zhang Rui 已提交
199 200


201 202 203 204
Then next two dynamic attributes are created/removed in pairs. They represent
the relationship between a thermal zone and its associated cooling device.
They are created/removed for each successful execution of
thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
Z
Zhang Rui 已提交
205

206 207 208
/sys/class/thermal/thermal_zone[0-*]:
    |---cdev[0-*]:		[0-*]th cooling device in current thermal zone
    |---cdev[0-*]_trip_point:	Trip point that cdev[0-*] is associated with
J
Javi Merino 已提交
209 210
    |---cdev[0-*]_weight:       Influence of the cooling device in
                                this thermal zone
Z
Zhang Rui 已提交
211

Z
Zhang Rui 已提交
212
Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
213 214 215 216 217
the generic thermal driver also creates a hwmon sysfs I/F for each _type_
of thermal zone device. E.g. the generic thermal driver registers one hwmon
class device and build the associated hwmon sysfs I/F for all the registered
ACPI thermal zones.

Z
Zhang Rui 已提交
218
/sys/class/hwmon/hwmon[0-*]:
219 220 221 222
    |---name:			The type of the thermal zone devices
    |---temp[1-*]_input:	The current temperature of thermal zone [1-*]
    |---temp[1-*]_critical:	The critical trip point of thermal zone [1-*]

Z
Zhang Rui 已提交
223
Please read Documentation/hwmon/sysfs-interface for additional information.
Z
Zhang Rui 已提交
224 225 226 227 228

***************************
* Thermal zone attributes *
***************************

229 230 231 232 233 234 235 236 237 238 239 240 241 242
type
	Strings which represent the thermal zone type.
	This is given by thermal zone driver as part of registration.
	E.g: "acpitz" indicates it's an ACPI thermal device.
	In order to keep it consistent with hwmon sys attribute; this should
	be a short, lowercase string, not containing spaces nor dashes.
	RO, Required

temp
	Current temperature as reported by thermal zone (sensor).
	Unit: millidegree Celsius
	RO, Required

mode
Z
Zhang Rui 已提交
243
	One of the predefined values in [enabled, disabled].
244 245 246
	This file gives information about the algorithm that is currently
	managing the thermal zone. It can be either default kernel based
	algorithm or user space application.
Z
Zhang Rui 已提交
247 248 249 250
	enabled		= enable Kernel Thermal management.
	disabled	= Preventing kernel thermal zone driver actions upon
			  trip points so that user application can take full
			  charge of the thermal management.
251 252
	RW, Optional

253 254 255 256
policy
	One of the various thermal governors used for a particular zone.
	RW, Required

257 258 259 260 261 262 263 264 265 266 267
trip_point_[0-*]_temp
	The temperature above which trip point will be fired.
	Unit: millidegree Celsius
	RO, Optional

trip_point_[0-*]_type
	Strings which indicate the type of the trip point.
	E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
	thermal zone.
	RO, Optional

D
Durgadoss R 已提交
268 269 270 271 272
trip_point_[0-*]_hyst
	The hysteresis value for a trip point, represented as an integer
	Unit: Celsius
	RW, Optional

273 274 275 276 277 278 279 280 281 282
cdev[0-*]
	Sysfs link to the thermal cooling device node where the sys I/F
	for cooling device throttling control represents.
	RO, Optional

cdev[0-*]_trip_point
	The trip point with which cdev[0-*] is associated in this thermal
	zone; -1 means the cooling device is not associated with any trip
	point.
	RO, Optional
283

J
Javi Merino 已提交
284 285 286 287 288 289 290 291
cdev[0-*]_weight
        The influence of cdev[0-*] in this thermal zone. This value
        is relative to the rest of cooling devices in the thermal
        zone. For example, if a cooling device has a weight double
        than that of other, it's twice as effective in cooling the
        thermal zone.
        RW, Optional

292 293 294 295 296 297 298
passive
	Attribute is only present for zones in which the passive cooling
	policy is not supported by native thermal driver. Default is zero
	and can be set to a temperature (in millidegrees) to enable a
	passive trip point for the zone. Activation is done by polling with
	an interval of 1 second.
	Unit: millidegrees Celsius
299
	Valid values: 0 (disabled) or greater than 1000
300
	RW, Optional
301

302 303 304 305 306 307 308 309 310 311
emul_temp
	Interface to set the emulated temperature method in thermal zone
	(sensor). After setting this temperature, the thermal zone may pass
	this temperature to platform emulation function if registered or
	cache it locally. This is useful in debugging different temperature
	threshold and its associated cooling action. This is write only node
	and writing 0 on this node should disable emulation.
	Unit: millidegree Celsius
	WO, Optional

312 313 314 315
	  WARNING: Be careful while enabling this option on production systems,
	  because userland can easily disable the thermal policy by simply
	  flooding this sysfs node with low temperature values.

316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361
sustainable_power
	An estimate of the sustained power that can be dissipated by
	the thermal zone. Used by the power allocator governor. For
	more information see Documentation/thermal/power_allocator.txt
	Unit: milliwatts
	RW, Optional

k_po
	The proportional term of the power allocator governor's PID
	controller during temperature overshoot. Temperature overshoot
	is when the current temperature is above the "desired
	temperature" trip point. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

k_pu
	The proportional term of the power allocator governor's PID
	controller during temperature undershoot. Temperature undershoot
	is when the current temperature is below the "desired
	temperature" trip point. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

k_i
	The integral term of the power allocator governor's PID
	controller. This term allows the PID controller to compensate
	for long term drift. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

k_d
	The derivative term of the power allocator governor's PID
	controller. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

integral_cutoff
	Temperature offset from the desired temperature trip point
	above which the integral term of the power allocator
	governor's PID controller starts accumulating errors. For
	example, if integral_cutoff is 0, then the integral term only
	accumulates error when temperature is above the desired
	temperature trip point. For more information see
	Documentation/thermal/power_allocator.txt
	RW, Optional

362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382
*****************************
* Cooling device attributes *
*****************************

type
	String which represents the type of device, e.g:
	- for generic ACPI: should be "Fan", "Processor" or "LCD"
	- for memory controller device on intel_menlow platform:
	  should be "Memory controller".
	RO, Required

max_state
	The maximum permissible cooling state of this cooling device.
	RO, Required

cur_state
	The current cooling state of this cooling device.
	The value can any integer numbers between 0 and max_state:
	- cur_state == 0 means no cooling
	- cur_state == max_state means the maximum cooling.
	RW, Required
Z
Zhang Rui 已提交
383 384 385

3. A simple implementation

386 387 388 389 390
ACPI thermal zone may support multiple trip points like critical, hot,
passive, active. If an ACPI thermal zone supports critical, passive,
active[0] and active[1] at the same time, it may register itself as a
thermal_zone_device (thermal_zone1) with 4 trip points in all.
It has one processor and one fan, which are both registered as
J
Javi Merino 已提交
391 392
thermal_cooling_device. Both are considered to have the same
effectiveness in cooling the thermal zone.
393 394 395

If the processor is listed in _PSL method, and the fan is listed in _AL0
method, the sys I/F structure will be built like this:
Z
Zhang Rui 已提交
396 397 398 399

/sys/class/thermal:

|thermal_zone1:
400 401
    |---type:			acpitz
    |---temp:			37000
Z
Zhang Rui 已提交
402
    |---mode:			enabled
403
    |---policy:			step_wise
404 405 406 407 408 409 410 411 412 413
    |---trip_point_0_temp:	100000
    |---trip_point_0_type:	critical
    |---trip_point_1_temp:	80000
    |---trip_point_1_type:	passive
    |---trip_point_2_temp:	70000
    |---trip_point_2_type:	active0
    |---trip_point_3_temp:	60000
    |---trip_point_3_type:	active1
    |---cdev0:			--->/sys/class/thermal/cooling_device0
    |---cdev0_trip_point:	1	/* cdev0 can be used for passive */
J
Javi Merino 已提交
414
    |---cdev0_weight:           1024
415 416
    |---cdev1:			--->/sys/class/thermal/cooling_device3
    |---cdev1_trip_point:	2	/* cdev1 can be used for active[0]*/
J
Javi Merino 已提交
417
    |---cdev1_weight:           1024
Z
Zhang Rui 已提交
418 419

|cooling_device0:
420 421 422
    |---type:			Processor
    |---max_state:		8
    |---cur_state:		0
Z
Zhang Rui 已提交
423 424

|cooling_device3:
425 426 427
    |---type:			Fan
    |---max_state:		2
    |---cur_state:		0
Z
Zhang Rui 已提交
428 429 430 431

/sys/class/hwmon:

|hwmon0:
432 433 434
    |---name:			acpitz
    |---temp1_input:		37000
    |---temp1_crit:		100000
435 436 437 438 439 440

4. Event Notification

The framework includes a simple notification mechanism, in the form of a
netlink event. Netlink socket initialization is done during the _init_
of the framework. Drivers which intend to use the notification mechanism
441
just need to call thermal_generate_netlink_event() with two arguments viz
442 443 444
(originator, event). The originator is a pointer to struct thermal_zone_device
from where the event has been originated. An integer which represents the
thermal zone device will be used in the message to identify the zone. The
445 446 447
event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
crosses any of the configured thresholds.
448 449 450 451 452 453 454 455 456 457 458 459 460 461 462

5. Export Symbol APIs:

5.1: get_tz_trend:
This function returns the trend of a thermal zone, i.e the rate of change
of temperature of the thermal zone. Ideally, the thermal sensor drivers
are supposed to implement the callback. If they don't, the thermal
framework calculated the trend by comparing the previous and the current
temperature values.

5.2:get_thermal_instance:
This function returns the thermal_instance corresponding to a given
{thermal_zone, cooling_device, trip_point} combination. Returns NULL
if such an instance does not exist.

463
5.3:thermal_notify_framework:
464 465 466 467 468 469 470 471 472 473 474
This function handles the trip events from sensor drivers. It starts
throttling the cooling devices according to the policy configured.
For CRITICAL and HOT trip points, this notifies the respective drivers,
and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
The throttling policy is based on the configured platform data; if no
platform data is provided, this uses the step_wise throttling policy.

5.4:thermal_cdev_update:
This function serves as an arbitrator to set the state of a cooling
device. It sets the cooling device to the deepest cooling state if
possible.