Kconfig 12.6 KB
Newer Older
L
Linus Torvalds 已提交
1 2 3 4
#
# Block device driver configuration
#

J
Jan Engelhardt 已提交
5
menuconfig MD
L
Linus Torvalds 已提交
6
	bool "Multiple devices driver support (RAID and LVM)"
J
Jan Engelhardt 已提交
7
	depends on BLOCK
L
Linus Torvalds 已提交
8 9 10 11
	help
	  Support multiple physical spindles through a single logical device.
	  Required for RAID and logical volume management.

J
Jan Engelhardt 已提交
12 13
if MD

L
Linus Torvalds 已提交
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
config BLK_DEV_MD
	tristate "RAID support"
	---help---
	  This driver lets you combine several hard disk partitions into one
	  logical block device. This can be used to simply append one
	  partition to another one or to combine several redundant hard disks
	  into a RAID1/4/5 device so as to provide protection against hard
	  disk failures. This is called "Software RAID" since the combining of
	  the partitions is done by the kernel. "Hardware RAID" means that the
	  combining is done by a dedicated controller; if you have such a
	  controller, you do not need to say Y here.

	  More information about Software RAID on Linux is contained in the
	  Software RAID mini-HOWTO, available from
	  <http://www.tldp.org/docs.html#howto>. There you will also learn
	  where to get the supporting user space utilities raidtools.

	  If unsure, say N.

33 34
config MD_AUTODETECT
	bool "Autodetect RAID arrays during kernel boot"
35
	depends on BLK_DEV_MD=y
36 37 38 39 40 41 42 43 44 45 46
	default y
	---help---
	  If you say Y here, then the kernel will try to autodetect raid
	  arrays as part of its boot process. 

	  If you don't use raid and say Y, this autodetection can cause 
	  a several-second delay in the boot time due to various
	  synchronisation steps that are part of this step.

	  If unsure, say Y.

L
Linus Torvalds 已提交
47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102
config MD_LINEAR
	tristate "Linear (append) mode"
	depends on BLK_DEV_MD
	---help---
	  If you say Y here, then your multiple devices driver will be able to
	  use the so-called linear mode, i.e. it will combine the hard disk
	  partitions by simply appending one to the other.

	  To compile this as a module, choose M here: the module
	  will be called linear.

	  If unsure, say Y.

config MD_RAID0
	tristate "RAID-0 (striping) mode"
	depends on BLK_DEV_MD
	---help---
	  If you say Y here, then your multiple devices driver will be able to
	  use the so-called raid0 mode, i.e. it will combine the hard disk
	  partitions into one logical device in such a fashion as to fill them
	  up evenly, one chunk here and one chunk there. This will increase
	  the throughput rate if the partitions reside on distinct disks.

	  Information about Software RAID on Linux is contained in the
	  Software-RAID mini-HOWTO, available from
	  <http://www.tldp.org/docs.html#howto>. There you will also
	  learn where to get the supporting user space utilities raidtools.

	  To compile this as a module, choose M here: the module
	  will be called raid0.

	  If unsure, say Y.

config MD_RAID1
	tristate "RAID-1 (mirroring) mode"
	depends on BLK_DEV_MD
	---help---
	  A RAID-1 set consists of several disk drives which are exact copies
	  of each other.  In the event of a mirror failure, the RAID driver
	  will continue to use the operational mirrors in the set, providing
	  an error free MD (multiple device) to the higher levels of the
	  kernel.  In a set with N drives, the available space is the capacity
	  of a single drive, and the set protects against a failure of (N - 1)
	  drives.

	  Information about Software RAID on Linux is contained in the
	  Software-RAID mini-HOWTO, available from
	  <http://www.tldp.org/docs.html#howto>.  There you will also
	  learn where to get the supporting user space utilities raidtools.

	  If you want to use such a RAID-1 set, say Y.  To compile this code
	  as a module, choose M here: the module will be called raid1.

	  If unsure, say Y.

config MD_RAID10
103 104
	tristate "RAID-10 (mirrored striping) mode"
	depends on BLK_DEV_MD
L
Linus Torvalds 已提交
105 106
	---help---
	  RAID-10 provides a combination of striping (RAID-0) and
107
	  mirroring (RAID-1) with easier configuration and more flexible
L
Linus Torvalds 已提交
108 109 110 111 112 113 114 115 116 117 118 119 120
	  layout.
	  Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
	  be the same size (or at least, only as much as the smallest device
	  will be used).
	  RAID-10 provides a variety of layouts that provide different levels
	  of redundancy and performance.

	  RAID-10 requires mdadm-1.7.0 or later, available at:

	  ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/

	  If unsure, say Y.

121 122
config MD_RAID456
	tristate "RAID-4/RAID-5/RAID-6 mode"
L
Linus Torvalds 已提交
123
	depends on BLK_DEV_MD
124
	select RAID6_PQ
D
Dan Williams 已提交
125 126
	select ASYNC_MEMCPY
	select ASYNC_XOR
127 128
	select ASYNC_PQ
	select ASYNC_RAID6_RECOV
L
Linus Torvalds 已提交
129 130 131 132 133 134 135 136 137
	---help---
	  A RAID-5 set of N drives with a capacity of C MB per drive provides
	  the capacity of C * (N - 1) MB, and protects against a failure
	  of a single drive. For a given sector (row) number, (N - 1) drives
	  contain data sectors, and one drive contains the parity protection.
	  For a RAID-4 set, the parity blocks are present on a single drive,
	  while a RAID-5 set distributes the parity across the drives in one
	  of the available parity distribution methods.

138 139 140 141 142 143 144 145
	  A RAID-6 set of N drives with a capacity of C MB per drive
	  provides the capacity of C * (N - 2) MB, and protects
	  against a failure of any two drives. For a given sector
	  (row) number, (N - 2) drives contain data sectors, and two
	  drives contains two independent redundancy syndromes.  Like
	  RAID-5, RAID-6 distributes the syndromes across the drives
	  in one of the available parity distribution methods.

L
Linus Torvalds 已提交
146 147 148 149 150
	  Information about Software RAID on Linux is contained in the
	  Software-RAID mini-HOWTO, available from
	  <http://www.tldp.org/docs.html#howto>. There you will also
	  learn where to get the supporting user space utilities raidtools.

151
	  If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To
L
Linus Torvalds 已提交
152
	  compile this code as a module, choose M here: the module
153
	  will be called raid456.
L
Linus Torvalds 已提交
154 155 156

	  If unsure, say Y.

157 158 159 160 161 162 163 164 165 166
config MULTICORE_RAID456
	bool "RAID-4/RAID-5/RAID-6 Multicore processing (EXPERIMENTAL)"
	depends on MD_RAID456
	depends on SMP
	depends on EXPERIMENTAL
	---help---
	  Enable the raid456 module to dispatch per-stripe raid operations to a
	  thread pool.

	  If unsure, say N.
167

L
Linus Torvalds 已提交
168 169 170 171
config MD_MULTIPATH
	tristate "Multipath I/O support"
	depends on BLK_DEV_MD
	help
172 173 174 175
	  MD_MULTIPATH provides a simple multi-path personality for use
	  the MD framework.  It is not under active development.  New
	  projects should consider using DM_MULTIPATH which has more
	  features and more testing.
L
Linus Torvalds 已提交
176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202

	  If unsure, say N.

config MD_FAULTY
	tristate "Faulty test module for MD"
	depends on BLK_DEV_MD
	help
	  The "faulty" module allows for a block device that occasionally returns
	  read or write errors.  It is useful for testing.

	  In unsure, say N.

config BLK_DEV_DM
	tristate "Device mapper support"
	---help---
	  Device-mapper is a low level volume manager.  It works by allowing
	  people to specify mappings for ranges of logical sectors.  Various
	  mapping types are available, in addition people may write their own
	  modules containing custom mappings if they wish.

	  Higher level volume managers such as LVM2 use this driver.

	  To compile this as a module, choose M here: the module will be
	  called dm-mod.

	  If unsure, say N.

B
Bryn Reeves 已提交
203 204
config DM_DEBUG
	boolean "Device mapper debugging support"
205
	depends on BLK_DEV_DM
B
Bryn Reeves 已提交
206 207 208 209 210
	---help---
	  Enable this for messages that may help debug device-mapper problems.

	  If unsure, say N.

M
Mikulas Patocka 已提交
211 212 213 214 215 216 217 218
config DM_BUFIO
       tristate
       depends on BLK_DEV_DM && EXPERIMENTAL
       ---help---
	 This interface allows you to do buffered I/O on a device and acts
	 as a cache, holding recently-read blocks in memory and performing
	 delayed writes.

J
Joe Thornber 已提交
219 220
source "drivers/md/persistent-data/Kconfig"

L
Linus Torvalds 已提交
221 222
config DM_CRYPT
	tristate "Crypt target support"
223
	depends on BLK_DEV_DM
L
Linus Torvalds 已提交
224
	select CRYPTO
H
Herbert Xu 已提交
225
	select CRYPTO_CBC
L
Linus Torvalds 已提交
226 227 228 229 230 231 232 233 234 235 236 237 238 239 240
	---help---
	  This device-mapper target allows you to create a device that
	  transparently encrypts the data on it. You'll need to activate
	  the ciphers you're going to use in the cryptoapi configuration.

	  Information on how to use dm-crypt can be found on

	  <http://www.saout.de/misc/dm-crypt/>

	  To compile this code as a module, choose M here: the module will
	  be called dm-crypt.

	  If unsure, say N.

config DM_SNAPSHOT
241 242
       tristate "Snapshot target"
       depends on BLK_DEV_DM
L
Linus Torvalds 已提交
243
       ---help---
244
         Allow volume managers to take writable snapshots of a device.
L
Linus Torvalds 已提交
245

J
Joe Thornber 已提交
246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262
config DM_THIN_PROVISIONING
       tristate "Thin provisioning target (EXPERIMENTAL)"
       depends on BLK_DEV_DM && EXPERIMENTAL
       select DM_PERSISTENT_DATA
       ---help---
         Provides thin provisioning and snapshots that share a data store.

config DM_DEBUG_BLOCK_STACK_TRACING
	boolean "Keep stack trace of thin provisioning block lock holders"
	depends on STACKTRACE_SUPPORT && DM_THIN_PROVISIONING
	select STACKTRACE
	---help---
	  Enable this for messages that may help debug problems with the
	  block manager locking used by thin provisioning.

	  If unsure, say N.

L
Linus Torvalds 已提交
263
config DM_MIRROR
264 265
       tristate "Mirror target"
       depends on BLK_DEV_DM
L
Linus Torvalds 已提交
266 267 268 269
       ---help---
         Allow volume managers to mirror logical volumes, also
         needed for live data migration tools such as 'pvmove'.

N
NeilBrown 已提交
270
config DM_RAID
271
       tristate "RAID 1/4/5/6/10 target"
272
       depends on BLK_DEV_DM
273
       select MD_RAID1
274
       select MD_RAID10
N
NeilBrown 已提交
275 276 277
       select MD_RAID456
       select BLK_DEV_MD
       ---help---
278
	 A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings
N
NeilBrown 已提交
279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295

	 A RAID-5 set of N drives with a capacity of C MB per drive provides
	 the capacity of C * (N - 1) MB, and protects against a failure
	 of a single drive. For a given sector (row) number, (N - 1) drives
	 contain data sectors, and one drive contains the parity protection.
	 For a RAID-4 set, the parity blocks are present on a single drive,
	 while a RAID-5 set distributes the parity across the drives in one
	 of the available parity distribution methods.

	 A RAID-6 set of N drives with a capacity of C MB per drive
	 provides the capacity of C * (N - 2) MB, and protects
	 against a failure of any two drives. For a given sector
	 (row) number, (N - 2) drives contain data sectors, and two
	 drives contains two independent redundancy syndromes.  Like
	 RAID-5, RAID-6 distributes the syndromes across the drives
	 in one of the available parity distribution methods.

J
Jonthan Brassow 已提交
296 297 298 299 300 301 302 303 304 305 306
config DM_LOG_USERSPACE
	tristate "Mirror userspace logging (EXPERIMENTAL)"
	depends on DM_MIRROR && EXPERIMENTAL && NET
	select CONNECTOR
	---help---
	  The userspace logging module provides a mechanism for
	  relaying the dm-dirty-log API to userspace.  Log designs
	  which are more suited to userspace implementation (e.g.
	  shared storage logs) or experimental logs can be implemented
	  by leveraging this framework.

L
Linus Torvalds 已提交
307
config DM_ZERO
308 309
	tristate "Zero target"
	depends on BLK_DEV_DM
L
Linus Torvalds 已提交
310 311 312 313 314
	---help---
	  A target that discards writes, and returns all zeroes for
	  reads.  Useful in some recovery situations.

config DM_MULTIPATH
315 316
	tristate "Multipath target"
	depends on BLK_DEV_DM
317 318 319 320 321
	# nasty syntax but means make DM_MULTIPATH independent
	# of SCSI_DH if the latter isn't defined but if
	# it is, DM_MULTIPATH must depend on it.  We get a build
	# error if SCSI_DH=m and DM_MULTIPATH=y
	depends on SCSI_DH || !SCSI_DH
L
Linus Torvalds 已提交
322 323 324
	---help---
	  Allow volume managers to support multipath hardware.

325 326 327 328 329 330 331 332 333
config DM_MULTIPATH_QL
	tristate "I/O Path Selector based on the number of in-flight I/Os"
	depends on DM_MULTIPATH
	---help---
	  This path selector is a dynamic load balancer which selects
	  the path with the least number of in-flight I/Os.

	  If unsure, say N.

334 335 336 337 338 339 340 341 342 343
config DM_MULTIPATH_ST
	tristate "I/O Path Selector based on the service time"
	depends on DM_MULTIPATH
	---help---
	  This path selector is a dynamic load balancer which selects
	  the path expected to complete the incoming I/O in the shortest
	  time.

	  If unsure, say N.

H
Heinz Mauelshagen 已提交
344 345 346 347 348 349 350 351 352
config DM_DELAY
	tristate "I/O delaying target (EXPERIMENTAL)"
	depends on BLK_DEV_DM && EXPERIMENTAL
	---help---
	A target that delays reads and/or writes and can send
	them to different devices.  Useful for testing.

	If unsure, say N.

M
Mike Anderson 已提交
353
config DM_UEVENT
354 355
	bool "DM uevents"
	depends on BLK_DEV_DM
M
Mike Anderson 已提交
356 357 358
	---help---
	Generate udev events for DM events.

J
Josef Bacik 已提交
359 360 361 362 363 364
config DM_FLAKEY
       tristate "Flakey target (EXPERIMENTAL)"
       depends on BLK_DEV_DM && EXPERIMENTAL
       ---help---
         A target that intermittently fails I/O for debugging purposes.

M
Mikulas Patocka 已提交
365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384
config DM_VERITY
	tristate "Verity target support (EXPERIMENTAL)"
	depends on BLK_DEV_DM && EXPERIMENTAL
	select CRYPTO
	select CRYPTO_HASH
	select DM_BUFIO
	---help---
	  This device-mapper target creates a read-only device that
	  transparently validates the data on one underlying device against
	  a pre-generated tree of cryptographic checksums stored on a second
	  device.

	  You'll need to activate the digests you're going to use in the
	  cryptoapi configuration.

	  To compile this code as a module, choose M here: the module will
	  be called dm-verity.

	  If unsure, say N.

J
Jan Engelhardt 已提交
385
endif # MD