# Generic thermal sysfs drivers configuration
#

menuconfig THERMAL
6
	tristate "Generic Thermal sysfs driver"
Z
Zhang Rui 已提交
7 8 9 10
	help
	  Generic Thermal Sysfs driver offers a generic mechanism for
	  thermal management. Usually it's made up of one or more thermal
	  zone and cooling device.
11
	  Each thermal zone contains its own temperature, trip points,
Z
Zhang Rui 已提交
12 13
	  cooling devices.
	  All platforms with ACPI thermal support can use this driver.
14
	  If you want this support, you should say Y or M here.
15

Z
Zhang Rui 已提交
16 17
if THERMAL

18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
config THERMAL_EMERGENCY_POWEROFF_DELAY_MS
	int "Emergency poweroff delay in milli-seconds"
	depends on THERMAL
	default 0
	help
	  Thermal subsystem will issue a graceful shutdown when
	  critical temperatures are reached using orderly_poweroff(). In
	  case of failure of an orderly_poweroff(), the thermal emergency
	  poweroff kicks in after a delay has elapsed and shuts down the system.
	  This config is number of milliseconds to delay before emergency
	  poweroff kicks in. Similarly to the critical trip point,
	  the delay should be carefully profiled so as to give adequate
	  time for orderly_poweroff() to finish on regular execution.
	  If set to 0 emergency poweroff will not be supported.

	  In doubt, leave as 0.

35
config THERMAL_HWMON
36
	bool
37
	prompt "Expose thermal sensors as hwmon device"
38
	depends on HWMON=y || HWMON=THERMAL
39
	default y
40 41 42 43 44 45 46 47
	help
	  In case a sensor is registered with the thermal
	  framework, this option will also register it
	  as a hwmon. The sensor will then have the common
	  hwmon sysfs interface.

	  Say 'Y' here if you want all thermal sensors to
	  have hwmon sysfs interface too.
48

49 50 51 52 53 54 55 56 57 58 59 60 61
config THERMAL_OF
	bool
	prompt "APIs to parse thermal data out of device tree"
	depends on OF
	default y
	help
	  This options provides helpers to add the support to
	  read and parse thermal data definitions out of the
	  device tree blob.

	  Say 'Y' here if you need to build thermal infrastructure
	  based on device tree.

62 63 64 65 66 67 68 69 70 71 72
config THERMAL_WRITABLE_TRIPS
	bool "Enable writable trip points"
	help
	  This option allows the system integrator to choose whether
	  trip temperatures can be changed from userspace. The
	  writable trips need to be specified when setting up the
	  thermal zone but the choice here takes precedence.

	  Say 'Y' here if you would like to allow userspace tools to
	  change trip temperatures.

Z
Zhang Rui 已提交
73 74 75 76 77 78 79 80 81
choice
	prompt "Default Thermal governor"
	default THERMAL_DEFAULT_GOV_STEP_WISE
	help
	  This option sets which thermal governor shall be loaded at
	  startup. If in doubt, select 'step_wise'.

config THERMAL_DEFAULT_GOV_STEP_WISE
	bool "step_wise"
82
	select THERMAL_GOV_STEP_WISE
Z
Zhang Rui 已提交
83 84 85 86 87 88
	help
	  Use the step_wise governor as default. This throttles the
	  devices one step at a time.

config THERMAL_DEFAULT_GOV_FAIR_SHARE
	bool "fair_share"
89
	select THERMAL_GOV_FAIR_SHARE
Z
Zhang Rui 已提交
90 91 92 93 94 95 96
	help
	  Use the fair_share governor as default. This throttles the
	  devices based on their 'contribution' to a zone. The
	  contribution should be provided through platform data.

config THERMAL_DEFAULT_GOV_USER_SPACE
	bool "user_space"
97
	select THERMAL_GOV_USER_SPACE
Z
Zhang Rui 已提交
98 99
	help
	  Select this if you want to let the user space manage the
100
	  platform thermals.
Z
Zhang Rui 已提交
101

102 103 104 105 106 107 108 109
config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
	bool "power_allocator"
	select THERMAL_GOV_POWER_ALLOCATOR
	help
	  Select this if you want to control temperature based on
	  system and device power allocation. This governor can only
	  operate on cooling devices that implement the power API.

Z
Zhang Rui 已提交
110 111
endchoice

112
config THERMAL_GOV_FAIR_SHARE
Z
Zhang Rui 已提交
113 114 115 116
	bool "Fair-share thermal governor"
	help
	  Enable this to manage platform thermals using fair-share governor.

117
config THERMAL_GOV_STEP_WISE
Z
Zhang Rui 已提交
118 119 120
	bool "Step_wise thermal governor"
	help
	  Enable this to manage platform thermals using a simple linear
L
Luka Perkov 已提交
121
	  governor.
Z
Zhang Rui 已提交
122

123 124 125 126 127 128 129 130 131 132
config THERMAL_GOV_BANG_BANG
	bool "Bang Bang thermal governor"
	default n
	help
	  Enable this to manage platform thermals using bang bang governor.

	  Say 'Y' here if you want to use two point temperature regulation
	  used for fans without throttling.  Some fan drivers depend on this
	  governor to be enabled (e.g. acerhdf).

133
config THERMAL_GOV_USER_SPACE
Z
Zhang Rui 已提交
134 135 136 137
	bool "User_space thermal governor"
	help
	  Enable this to let the user space manage the platform thermals.

138 139 140 141 142 143
config THERMAL_GOV_POWER_ALLOCATOR
	bool "Power allocator thermal governor"
	help
	  Enable this to manage platform thermals by dynamically
	  allocating and limiting power to devices.

144
config CPU_THERMAL
145
	bool "generic cpu cooling support"
Z
Zhang Rui 已提交
146
	depends on CPU_FREQ
147
	depends on THERMAL_OF
148 149
	help
	  This implements the generic cpu cooling mechanism through frequency
150 151
	  reduction. An ACPI version of this already exists
	  (drivers/acpi/processor_thermal.c).
152 153
	  This will be useful for platforms using the generic thermal interface
	  and not the ACPI interface.
154

155 156
	  If you want this support, you should say Y here.

157 158 159 160 161 162 163 164 165 166
config CLOCK_THERMAL
	bool "Generic clock cooling support"
	depends on COMMON_CLK
	depends on PM_OPP
	help
	  This entry implements the generic clock cooling mechanism through
	  frequency clipping. Typically used to cool off co-processors. The
	  device that is configured to use this cooling mechanism will be
	  controlled to reduce clock frequency whenever temperature is high.

Ø
Ørjan Eide 已提交
167 168 169 170 171 172 173 174 175 176 177 178 179 180
config DEVFREQ_THERMAL
	bool "Generic device cooling support"
	depends on PM_DEVFREQ
	depends on PM_OPP
	help
	  This implements the generic devfreq cooling mechanism through
	  frequency reduction for devices using devfreq.

	  This will throttle the device by limiting the maximum allowed DVFS
	  frequency corresponding to the cooling level.

	  In order to use the power extensions of the cooling device,
	  devfreq should use the simple_ondemand governor.

181 182
	  If you want this support, you should say Y here.

183 184 185 186 187 188 189 190
config THERMAL_EMULATION
	bool "Thermal emulation mode support"
	help
	  Enable this option to make a emul_temp sysfs node in thermal zone
	  directory to support temperature emulation. With emulation sysfs node,
	  user can manually input temperature and test the different trip
	  threshold behaviour for simulation purpose.

191 192 193 194
	  WARNING: Be careful while enabling this option on production systems,
	  because userland can easily disable the thermal policy by simply
	  flooding this sysfs node with low temperature values.

195 196
config HISI_THERMAL
	tristate "Hisilicon thermal driver"
L
Leo Yan 已提交
197
	depends on ARCH_HISI || COMPILE_TEST
198
	depends on HAS_IOMEM
L
Leo Yan 已提交
199 200
	depends on OF
	default y
201 202 203 204 205
	help
	  Enable this to plug hisilicon's thermal sensor driver into the Linux
	  thermal framework. cpufreq is used as the cooling device to throttle
	  CPUs when the passive trip is crossed.

206 207
config IMX_THERMAL
	tristate "Temperature sensor driver for Freescale i.MX SoCs"
208
	depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
209 210 211 212 213 214 215 216
	depends on MFD_SYSCON
	depends on OF
	help
	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
	  It supports one critical trip point and one passive trip point.  The
	  cpufreq is used as the cooling device to throttle CPUs when the
	  passive trip is crossed.

217 218 219 220 221 222 223 224 225 226
config MAX77620_THERMAL
	tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
	depends on MFD_MAX77620
	depends on OF
	help
	  Support for die junction temperature warning alarm for Maxim
	  Semiconductor PMIC MAX77620 device. Device generates two alarm
	  interrupts when PMIC die temperature cross the threshold of
	  120 degC and 140 degC.

227 228 229 230 231 232 233 234 235 236
config QORIQ_THERMAL
	tristate "QorIQ Thermal Monitoring Unit"
	depends on THERMAL_OF
	depends on HAS_IOMEM
	help
	  Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
	  It supports one critical trip point and one passive trip point. The
	  cpufreq is used as the cooling device to throttle CPUs when the
	  passive trip is crossed.

237
config SPEAR_THERMAL
238
	tristate "SPEAr thermal sensor driver"
239
	depends on PLAT_SPEAR || COMPILE_TEST
240
	depends on HAS_IOMEM
241
	depends on OF
242 243
	help
	  Enable this to plug the SPEAr thermal sensor driver into the Linux
L
Luka Perkov 已提交
244
	  thermal framework.
245

246 247
config ROCKCHIP_THERMAL
	tristate "Rockchip thermal driver"
248
	depends on ARCH_ROCKCHIP || COMPILE_TEST
249
	depends on RESET_CONTROLLER
250
	depends on HAS_IOMEM
251 252 253 254 255 256
	help
	  Rockchip thermal driver provides support for Temperature sensor
	  ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
	  trip point. Cpufreq is used as the cooling device and will throttle
	  CPUs when the Temperature crosses the passive trip point.

257 258
config RCAR_THERMAL
	tristate "Renesas R-Car thermal driver"
S
Simon Horman 已提交
259
	depends on ARCH_RENESAS || COMPILE_TEST
260
	depends on HAS_IOMEM
261 262
	help
	  Enable this to plug the R-Car thermal sensor driver into the Linux
L
Luka Perkov 已提交
263
	  thermal framework.
264

265 266 267 268 269 270 271 272 273
config RCAR_GEN3_THERMAL
	tristate "Renesas R-Car Gen3 thermal driver"
	depends on ARCH_RENESAS || COMPILE_TEST
	depends on HAS_IOMEM
	depends on OF
	help
	  Enable this to plug the R-Car Gen3 thermal sensor driver into the Linux
	  thermal framework.

274 275
config KIRKWOOD_THERMAL
	tristate "Temperature sensor on Marvell Kirkwood SoCs"
276
	depends on MACH_KIRKWOOD || COMPILE_TEST
277
	depends on HAS_IOMEM
278 279 280 281 282
	depends on OF
	help
	  Support for the Kirkwood thermal sensor driver into the Linux thermal
	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.

283 284
config DOVE_THERMAL
	tristate "Temperature sensor on Marvell Dove SoCs"
285
	depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
286
	depends on HAS_IOMEM
287 288 289 290 291
	depends on OF
	help
	  Support for the Dove thermal sensor driver in the Linux thermal
	  framework.

292
config DB8500_THERMAL
293 294
	tristate "DB8500 thermal management"
	depends on MFD_DB8500_PRCMU
295 296 297 298 299 300 301
	default y
	help
	  Adds DB8500 thermal management implementation according to the thermal
	  management framework. A thermal zone with several trip points will be
	  created. Cooling devices can be bound to the trip points to cool this
	  thermal zone if trip points reached.

302 303
config ARMADA_THERMAL
	tristate "Armada 370/XP thermal management"
304
	depends on ARCH_MVEBU || COMPILE_TEST
305
	depends on HAS_IOMEM
306 307 308 309 310
	depends on OF
	help
	  Enable this option if you want to have support for thermal management
	  controller present in Armada 370 and Armada XP SoC.

311 312 313 314 315 316 317 318 319 320
config DA9062_THERMAL
	tristate "DA9062/DA9061 Dialog Semiconductor thermal driver"
	depends on MFD_DA9062 || COMPILE_TEST
	depends on OF
	help
	  Enable this for the Dialog Semiconductor thermal sensor driver.
	  This will report PMIC junction over-temperature for one thermal trip
	  zone.
	  Compatible with the DA9062 and DA9061 PMICs.

321 322 323 324 325 326 327 328 329 330
config INTEL_POWERCLAMP
	tristate "Intel PowerClamp idle injection driver"
	depends on THERMAL
	depends on X86
	depends on CPU_SUP_INTEL
	help
	  Enable this to enable Intel PowerClamp idle injection driver. This
	  enforce idle time which results in more package C-state residency. The
	  user interface is exposed via generic thermal framework.

331 332
config X86_PKG_TEMP_THERMAL
	tristate "X86 package temperature thermal driver"
333
	depends on X86_THERMAL_VECTOR
334
	select THERMAL_GOV_USER_SPACE
335
	select THERMAL_WRITABLE_TRIPS
336 337 338 339 340 341 342
	default m
	help
	  Enable this to register CPU digital sensor for package temperature as
	  thermal zone. Each package will have its own thermal zone. There are
	  two trip points which can be set by user to get notifications via thermal
	  notification methods.

343 344
config INTEL_SOC_DTS_IOSF_CORE
	tristate
345
	depends on X86 && PCI
346 347 348 349 350 351 352
	select IOSF_MBI
	help
	  This is becoming a common feature for Intel SoCs to expose the additional
	  digital temperature sensors (DTSs) using side band interface (IOSF). This
	  implements the common set of helper functions to register, get temperature
	  and get/set thresholds on DTSs.

353 354
config INTEL_SOC_DTS_THERMAL
	tristate "Intel SoCs DTS thermal driver"
355
	depends on X86 && PCI
356
	select INTEL_SOC_DTS_IOSF_CORE
357
	select THERMAL_WRITABLE_TRIPS
358 359 360 361 362 363 364 365 366
	help
	  Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
	  temperature sensor (DTS). These SoCs have two additional DTSs in
	  addition to DTSs on CPU cores. Each DTS will be registered as a
	  thermal zone. There are two trip points. One of the trip point can
	  be set by user mode programs to get notifications via Linux thermal
	  notification methods.The other trip is a critical trip point, which
	  was set by the driver based on the TJ MAX temperature.

367 368 369 370 371 372 373 374 375 376
config INTEL_QUARK_DTS_THERMAL
	tristate "Intel Quark DTS thermal driver"
	depends on X86_INTEL_QUARK
	help
	  Enable this to register Intel Quark SoC (e.g. X1000) platform digital
	  temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
	  The DTS will be registered as a thermal zone. There are two trip points:
	  hot & critical. The critical trip point default value is set by
	  underlying BIOS/Firmware.

377 378 379
menu "ACPI INT340X thermal drivers"
source drivers/thermal/int340x_thermal/Kconfig
endmenu
380

381 382
config INTEL_BXT_PMIC_THERMAL
	tristate "Intel Broxton PMIC thermal driver"
383
	depends on X86 && INTEL_SOC_PMIC_BXTWC && REGMAP
384 385 386 387 388 389 390
	help
	  Select this driver for Intel Broxton PMIC with ADC channels monitoring
	  system temperature measurements and alerts.
	  This driver is used for monitoring the ADC channels of PMIC and handles
	  the alert trip point interrupts and notifies the thermal framework with
	  the trip point and temperature details of the zone.

391 392 393 394 395 396 397 398
config INTEL_PCH_THERMAL
	tristate "Intel PCH Thermal Reporting Driver"
	depends on X86 && PCI
	help
	  Enable this to support thermal reporting on certain intel PCHs.
	  Thermal reporting device will provide temperature reading,
	  programmable trip points and other information.

399 400 401
config MTK_THERMAL
	tristate "Temperature sensor driver for mediatek SoCs"
	depends on ARCH_MEDIATEK || COMPILE_TEST
402
	depends on HAS_IOMEM
403
	depends on NVMEM || NVMEM=n
404
	depends on RESET_CONTROLLER
405 406 407 408 409
	default y
	help
	  Enable this option if you want to have support for thermal management
	  controller present in Mediatek SoCs

410
menu "Broadcom thermal drivers"
411
depends on ARCH_BCM || ARCH_BCM2835 || COMPILE_TEST
412 413 414
source "drivers/thermal/broadcom/Kconfig"
endmenu

415
menu "Texas Instruments thermal drivers"
416
depends on ARCH_HAS_BANDGAP || COMPILE_TEST
417
depends on HAS_IOMEM
418 419
source "drivers/thermal/ti-soc-thermal/Kconfig"
endmenu
420

421
menu "Samsung thermal drivers"
422
depends on ARCH_EXYNOS || COMPILE_TEST
423 424 425
source "drivers/thermal/samsung/Kconfig"
endmenu

426 427 428 429 430
menu "STMicroelectronics thermal drivers"
depends on ARCH_STI && OF
source "drivers/thermal/st/Kconfig"
endmenu

431 432 433 434 435 436 437 438 439
config TANGO_THERMAL
	tristate "Tango thermal management"
	depends on ARCH_TANGO || COMPILE_TEST
	help
	  Enable the Tango thermal driver, which supports the primitive
	  temperature sensor embedded in Tango chips since the SMP8758.
	  This sensor only generates a 1-bit signal to indicate whether
	  the die temperature exceeds a programmable threshold.

440 441
source "drivers/thermal/tegra/Kconfig"

442 443
config QCOM_SPMI_TEMP_ALARM
	tristate "Qualcomm SPMI PMIC Temperature Alarm"
444
	depends on OF && SPMI && IIO
445 446 447 448 449 450 451 452
	select REGMAP_SPMI
	help
	  This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
	  PMIC devices. It shows up in sysfs as a thermal sensor with multiple
	  trip points. The temperature reported by the thermal sensor reflects the
	  real time die temperature if an ADC is present or an estimate of the
	  temperature based upon the over temperature stage value.

453 454 455 456 457 458 459 460 461 462
config GENERIC_ADC_THERMAL
	tristate "Generic ADC based thermal sensor"
	depends on IIO
	help
	  This enabled a thermal sysfs driver for the temperature sensor
	  which is connected to the General Purpose ADC. The ADC channel
	  is read via IIO framework and the channel information is provided
	  to this driver. This driver reports the temperature by reading ADC
	  channel and converts it to temperature based on lookup table.

463 464 465 466 467
menu "Qualcomm thermal drivers"
depends on (ARCH_QCOM && OF) || COMPILE_TEST
source "drivers/thermal/qcom/Kconfig"
endmenu

468 469 470 471 472 473 474 475
config ZX2967_THERMAL
	tristate "Thermal sensors on zx2967 SoC"
	depends on ARCH_ZX || COMPILE_TEST
	help
	  Enable the zx2967 thermal sensors driver, which supports
	  the primitive temperature sensor embedded in zx2967 SoCs.
	  This sensor generates the real time die temperature.

476 477 478 479 480 481 482 483
config UNIPHIER_THERMAL
	tristate "Socionext UniPhier thermal driver"
	depends on ARCH_UNIPHIER || COMPILE_TEST
	depends on THERMAL_OF && MFD_SYSCON
	help
	  Enable this to plug in UniPhier on-chip PVT thermal driver into the
	  thermal framework. The driver supports CPU thermal zone temperature
	  reporting and a couple of trip points.
Z
Zhang Rui 已提交
484
endif