# Generic thermal sysfs drivers configuration
#

menuconfig THERMAL
6
	tristate "Generic Thermal sysfs driver"
Z
Zhang Rui 已提交
7 8 9 10
	help
	  Generic Thermal Sysfs driver offers a generic mechanism for
	  thermal management. Usually it's made up of one or more thermal
	  zone and cooling device.
11
	  Each thermal zone contains its own temperature, trip points,
Z
Zhang Rui 已提交
12 13
	  cooling devices.
	  All platforms with ACPI thermal support can use this driver.
14
	  If you want this support, you should say Y or M here.
15

Z
Zhang Rui 已提交
16 17
if THERMAL

18
config THERMAL_HWMON
19
	bool
20
	prompt "Expose thermal sensors as hwmon device"
21
	depends on HWMON=y || HWMON=THERMAL
22
	default y
23 24 25 26 27 28 29 30
	help
	  In case a sensor is registered with the thermal
	  framework, this option will also register it
	  as a hwmon. The sensor will then have the common
	  hwmon sysfs interface.

	  Say 'Y' here if you want all thermal sensors to
	  have hwmon sysfs interface too.
31

32 33 34 35 36 37 38 39 40 41 42 43 44
config THERMAL_OF
	bool
	prompt "APIs to parse thermal data out of device tree"
	depends on OF
	default y
	help
	  This options provides helpers to add the support to
	  read and parse thermal data definitions out of the
	  device tree blob.

	  Say 'Y' here if you need to build thermal infrastructure
	  based on device tree.

Z
Zhang Rui 已提交
45 46 47 48 49 50 51 52 53
choice
	prompt "Default Thermal governor"
	default THERMAL_DEFAULT_GOV_STEP_WISE
	help
	  This option sets which thermal governor shall be loaded at
	  startup. If in doubt, select 'step_wise'.

config THERMAL_DEFAULT_GOV_STEP_WISE
	bool "step_wise"
54
	select THERMAL_GOV_STEP_WISE
Z
Zhang Rui 已提交
55 56 57 58 59 60
	help
	  Use the step_wise governor as default. This throttles the
	  devices one step at a time.

config THERMAL_DEFAULT_GOV_FAIR_SHARE
	bool "fair_share"
61
	select THERMAL_GOV_FAIR_SHARE
Z
Zhang Rui 已提交
62 63 64 65 66 67 68
	help
	  Use the fair_share governor as default. This throttles the
	  devices based on their 'contribution' to a zone. The
	  contribution should be provided through platform data.

config THERMAL_DEFAULT_GOV_USER_SPACE
	bool "user_space"
69
	select THERMAL_GOV_USER_SPACE
Z
Zhang Rui 已提交
70 71
	help
	  Select this if you want to let the user space manage the
72
	  platform thermals.
Z
Zhang Rui 已提交
73

74 75 76 77 78 79 80 81
config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
	bool "power_allocator"
	select THERMAL_GOV_POWER_ALLOCATOR
	help
	  Select this if you want to control temperature based on
	  system and device power allocation. This governor can only
	  operate on cooling devices that implement the power API.

Z
Zhang Rui 已提交
82 83
endchoice

84
config THERMAL_GOV_FAIR_SHARE
Z
Zhang Rui 已提交
85 86 87 88
	bool "Fair-share thermal governor"
	help
	  Enable this to manage platform thermals using fair-share governor.

89
config THERMAL_GOV_STEP_WISE
Z
Zhang Rui 已提交
90 91 92
	bool "Step_wise thermal governor"
	help
	  Enable this to manage platform thermals using a simple linear
L
Luka Perkov 已提交
93
	  governor.
Z
Zhang Rui 已提交
94

95 96 97 98 99 100 101 102 103 104
config THERMAL_GOV_BANG_BANG
	bool "Bang Bang thermal governor"
	default n
	help
	  Enable this to manage platform thermals using bang bang governor.

	  Say 'Y' here if you want to use two point temperature regulation
	  used for fans without throttling.  Some fan drivers depend on this
	  governor to be enabled (e.g. acerhdf).

105
config THERMAL_GOV_USER_SPACE
Z
Zhang Rui 已提交
106 107 108 109
	bool "User_space thermal governor"
	help
	  Enable this to let the user space manage the platform thermals.

110 111 112 113 114 115 116
config THERMAL_GOV_POWER_ALLOCATOR
	bool "Power allocator thermal governor"
	select THERMAL_POWER_ACTOR
	help
	  Enable this to manage platform thermals by dynamically
	  allocating and limiting power to devices.

117
config CPU_THERMAL
118
	bool "generic cpu cooling support"
Z
Zhang Rui 已提交
119
	depends on CPU_FREQ
120
	depends on THERMAL_OF
121 122
	help
	  This implements the generic cpu cooling mechanism through frequency
123 124
	  reduction. An ACPI version of this already exists
	  (drivers/acpi/processor_thermal.c).
125 126
	  This will be useful for platforms using the generic thermal interface
	  and not the ACPI interface.
127

128 129
	  If you want this support, you should say Y here.

130 131 132 133 134 135 136 137 138 139 140 141
config CLOCK_THERMAL
	bool "Generic clock cooling support"
	depends on COMMON_CLK
	depends on PM_OPP
	help
	  This entry implements the generic clock cooling mechanism through
	  frequency clipping. Typically used to cool off co-processors. The
	  device that is configured to use this cooling mechanism will be
	  controlled to reduce clock frequency whenever temperature is high.

	  If you want this support, you should say Y here.

142 143 144 145 146 147 148 149
config THERMAL_EMULATION
	bool "Thermal emulation mode support"
	help
	  Enable this option to make a emul_temp sysfs node in thermal zone
	  directory to support temperature emulation. With emulation sysfs node,
	  user can manually input temperature and test the different trip
	  threshold behaviour for simulation purpose.

150 151 152 153
	  WARNING: Be careful while enabling this option on production systems,
	  because userland can easily disable the thermal policy by simply
	  flooding this sysfs node with low temperature values.

154 155 156 157 158 159 160 161 162 163 164
config IMX_THERMAL
	tristate "Temperature sensor driver for Freescale i.MX SoCs"
	depends on CPU_THERMAL
	depends on MFD_SYSCON
	depends on OF
	help
	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
	  It supports one critical trip point and one passive trip point.  The
	  cpufreq is used as the cooling device to throttle CPUs when the
	  passive trip is crossed.

165 166 167
config SPEAR_THERMAL
	bool "SPEAr thermal sensor driver"
	depends on PLAT_SPEAR
168
	depends on OF
169 170
	help
	  Enable this to plug the SPEAr thermal sensor driver into the Linux
L
Luka Perkov 已提交
171
	  thermal framework.
172

173 174 175 176 177 178 179 180 181 182
config ROCKCHIP_THERMAL
	tristate "Rockchip thermal driver"
	depends on ARCH_ROCKCHIP
	depends on RESET_CONTROLLER
	help
	  Rockchip thermal driver provides support for Temperature sensor
	  ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
	  trip point. Cpufreq is used as the cooling device and will throttle
	  CPUs when the Temperature crosses the passive trip point.

183 184
config RCAR_THERMAL
	tristate "Renesas R-Car thermal driver"
185
	depends on ARCH_SHMOBILE || COMPILE_TEST
186
	depends on HAS_IOMEM
187 188
	help
	  Enable this to plug the R-Car thermal sensor driver into the Linux
L
Luka Perkov 已提交
189
	  thermal framework.
190

191 192
config KIRKWOOD_THERMAL
	tristate "Temperature sensor on Marvell Kirkwood SoCs"
193
	depends on MACH_KIRKWOOD
194 195 196 197 198
	depends on OF
	help
	  Support for the Kirkwood thermal sensor driver into the Linux thermal
	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.

199 200
config DOVE_THERMAL
	tristate "Temperature sensor on Marvell Dove SoCs"
201
	depends on ARCH_DOVE || MACH_DOVE
202 203 204 205 206
	depends on OF
	help
	  Support for the Dove thermal sensor driver in the Linux thermal
	  framework.

207 208 209 210 211 212 213 214 215 216
config DB8500_THERMAL
	bool "DB8500 thermal management"
	depends on ARCH_U8500
	default y
	help
	  Adds DB8500 thermal management implementation according to the thermal
	  management framework. A thermal zone with several trip points will be
	  created. Cooling devices can be bound to the trip points to cool this
	  thermal zone if trip points reached.

217 218 219 220 221 222 223 224
config ARMADA_THERMAL
	tristate "Armada 370/XP thermal management"
	depends on ARCH_MVEBU
	depends on OF
	help
	  Enable this option if you want to have support for thermal management
	  controller present in Armada 370 and Armada XP SoC.

225 226 227 228 229 230 231 232 233 234
config TEGRA_SOCTHERM
	tristate "Tegra SOCTHERM thermal management"
	depends on ARCH_TEGRA
	help
	  Enable this option for integrated thermal management support on NVIDIA
	  Tegra124 systems-on-chip. The driver supports four thermal zones
	  (CPU, GPU, MEM, PLLX). Cooling devices can be bound to the thermal
	  zones to manage temperatures. This option is also required for the
	  emergency thermal reset (thermtrip) feature to function.

235 236 237 238 239 240 241 242 243 244
config DB8500_CPUFREQ_COOLING
	tristate "DB8500 cpufreq cooling"
	depends on ARCH_U8500
	depends on CPU_THERMAL
	default y
	help
	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
	  bound to thermal zone trip points. When a trip point reached, the
	  bound cpufreq cooling device turns active to set CPU frequency low to
	  cool down the CPU.
245

246 247 248 249 250 251 252 253 254 255
config INTEL_POWERCLAMP
	tristate "Intel PowerClamp idle injection driver"
	depends on THERMAL
	depends on X86
	depends on CPU_SUP_INTEL
	help
	  Enable this to enable Intel PowerClamp idle injection driver. This
	  enforce idle time which results in more package C-state residency. The
	  user interface is exposed via generic thermal framework.

256 257
config X86_PKG_TEMP_THERMAL
	tristate "X86 package temperature thermal driver"
258
	depends on X86_THERMAL_VECTOR
259 260 261 262 263 264 265 266
	select THERMAL_GOV_USER_SPACE
	default m
	help
	  Enable this to register CPU digital sensor for package temperature as
	  thermal zone. Each package will have its own thermal zone. There are
	  two trip points which can be set by user to get notifications via thermal
	  notification methods.

267 268 269 270 271 272 273 274 275 276 277 278
config INTEL_SOC_DTS_THERMAL
	tristate "Intel SoCs DTS thermal driver"
	depends on X86 && IOSF_MBI
	help
	  Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
	  temperature sensor (DTS). These SoCs have two additional DTSs in
	  addition to DTSs on CPU cores. Each DTS will be registered as a
	  thermal zone. There are two trip points. One of the trip point can
	  be set by user mode programs to get notifications via Linux thermal
	  notification methods.The other trip is a critical trip point, which
	  was set by the driver based on the TJ MAX temperature.

279
config INT340X_THERMAL
280
	tristate "ACPI INT340X thermal drivers"
281
	depends on X86 && ACPI
282
	select THERMAL_GOV_USER_SPACE
283
	select ACPI_THERMAL_REL
284
	select ACPI_FAN
285 286 287 288 289 290 291 292 293 294 295 296 297 298
	help
	  Newer laptops and tablets that use ACPI may have thermal sensors and
	  other devices with thermal control capabilities outside the core
	  CPU/SOC, for thermal safety reasons.
	  They are exposed for the OS to use via the INT3400 ACPI device object
	  as the master, and INT3401~INT340B ACPI device objects as the slaves.
	  Enable this to expose the temperature information and cooling ability
	  from these objects to userspace via the normal thermal framework.
	  This means that a wide range of applications and GUI widgets can show
	  the information to the user or use this information for making
	  decisions. For example, the Intel Thermal Daemon can use this
	  information to allow the user to select his laptop to run without
	  turning on the fans.

299 300 301 302
config ACPI_THERMAL_REL
	tristate
	depends on ACPI

303 304 305
menu "Texas Instruments thermal drivers"
source "drivers/thermal/ti-soc-thermal/Kconfig"
endmenu
306

307
menu "Samsung thermal drivers"
308
depends on ARCH_EXYNOS
309 310 311
source "drivers/thermal/samsung/Kconfig"
endmenu

312 313 314 315 316
menu "STMicroelectronics thermal drivers"
depends on ARCH_STI && OF
source "drivers/thermal/st/Kconfig"
endmenu

317 318 319 320 321 322 323 324 325 326 327
config QCOM_SPMI_TEMP_ALARM
	tristate "Qualcomm SPMI PMIC Temperature Alarm"
	depends on OF && SPMI && IIO
	select REGMAP_SPMI
	help
	  This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
	  PMIC devices. It shows up in sysfs as a thermal sensor with multiple
	  trip points. The temperature reported by the thermal sensor reflects the
	  real time die temperature if an ADC is present or an estimate of the
	  temperature based upon the over temperature stage value.

Z
Zhang Rui 已提交
328
endif