1. 10 12月, 2009 2 次提交
  2. 03 12月, 2009 1 次提交
    • D
      x86, Calgary IOMMU quirk: Find nearest matching Calgary while walking up the PCI tree · 4528752f
      Darrick J. Wong 提交于
      On a multi-node x3950M2 system, there's a slight oddity in the
      PCI device tree for all secondary nodes:
      
       30:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1)
        \-33:00.0 PCI bridge: IBM CalIOC2 PCI-E Root Port (rev 01)
           \-34:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 1078 (rev 04)
      
      ...as compared to the primary node:
      
       00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1)
        \-01:00.0 VGA compatible controller: ATI Technologies Inc ES1000 (rev 02)
       03:00.0 PCI bridge: IBM CalIOC2 PCI-E Root Port (rev 01)
        \-04:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 1078 (rev 04)
      
      In both nodes, the LSI RAID controller hangs off a CalIOC2
      device, but on the secondary nodes, the BIOS hides the VGA
      device and substitutes the device tree ending with the disk
      controller.
      
      It would seem that Calgary devices don't necessarily appear at
      the top of the PCI tree, which means that the current code to
      find the Calgary IOMMU that goes with a particular device is
      buggy.
      
      Rather than walk all the way to the top of the PCI
      device tree and try to match bus number with Calgary descriptor,
      the code needs to examine each parent of the particular device;
      if it encounters a Calgary with a matching bus number, simply
      use that.
      
      Otherwise, we BUG() when the bus number of the Calgary doesn't
      match the bus number of whatever's at the top of the device tree.
      
      Extra note: This patch appears to work correctly for the x3950
      that came before the x3950 M2.
      Signed-off-by: NDarrick J. Wong <djwong@us.ibm.com>
      Acked-by: NMuli Ben-Yehuda <muli@il.ibm.com>
      Cc: FUJITA Tomonori <fujita.tomonori@lab.ntt.co.jp>
      Cc: Joerg Roedel <joerg.roedel@amd.com>
      Cc: Yinghai Lu <yhlu.kernel@gmail.com>
      Cc: Jon D. Mason <jdmason@kudzu.us>
      Cc: Corinna Schultz <coschult@us.ibm.com>
      Cc: <stable@kernel.org>
      LKML-Reference: <20091202230556.GG10295@tux1.beaverton.ibm.com>
      Signed-off-by: NIngo Molnar <mingo@elte.hu>
      4528752f
  3. 27 11月, 2009 35 次提交
  4. 25 11月, 2009 1 次提交
  5. 23 11月, 2009 1 次提交
    • J
      x86/amd-iommu: attach devices to pre-allocated domains early · be831297
      Joerg Roedel 提交于
      For some devices the ACPI table may define unity map
      requirements which must me met when the IOMMU is enabled. So
      we need to attach devices to their domains as early as
      possible so that these mappings are in place when needed.
      This patch assigns the domains right after they are
      allocated. Otherwise this can result in I/O page faults
      before a driver binds to a device and BIOS is still using
      it.
      
      Cc: stable@kernel.org
      Signed-off-by: NJoerg Roedel <joerg.roedel@amd.com>
      be831297