scripts/record_bag.py: change the default stop signal from SIGTERM to SIGINT
* when SIGTERM is used the last record file is incomplete and error is shown when trying to play or show info on it: E1026 16:23:16.325891 40186 record_file_reader.cc:88] [cyber_recorder] Record file is not complete. * instead of changing every record_bag.py --stop call: docs/howto/how_to_run_MSF_localization_module_on_your_local_computer.md:python /apollo/scripts/record_bag.py --stop docs/howto/how_to_run_MSF_localization_module_on_your_local_computer_cn.md:python /apollo/scripts/record_bag.py --stop docs/howto/how_to_run_NDT_localization_module_on_your_local_computer_cn.md:python ./scripts/record_bag.py --stop modules/dreamview/conf/hmi_modes/ipc1_mkz_close_loop.pb.txt: stop_command: "/apollo/scripts/record_bag.py --stop" modules/dreamview/conf/hmi_modes/ipc1_mkz_standard_debug.pb.txt: stop_command: "/apollo/scripts/record_bag.py --stop" modules/dreamview/conf/hmi_modes/mkz_close_loop.pb.txt: stop_command: "/apollo/scripts/record_bag.py --stop" modules/dreamview/conf/hmi_modes/mkz_standard_debug.pb.txt: stop_command: "/apollo/scripts/record_bag.py --stop" modules/dreamview/conf/hmi_modes/navigation.pb.txt: stop_command: "/apollo/scripts/record_bag.py --stop" modules/dreamview/conf/hmi_modes/rtk.pb.txt: stop_command: "/apollo/scripts/record_bag.py --stop" modules/dreamview/conf/hmi_modes/vehicle_calibration.pb.txt: stop_command: "/apollo/scripts/record_bag.py --stop --stop_signal SIGINT" like upstream did for some of them in: commit 4d428a30 Author: SeasoulChris <274224843@qq.com> Date: Wed Jul 15 20:43:49 2020 +0800 change recorder stop_signal to SIGINT lets change the default value, as it's not clear why SIGTERM was used in first place
Showing