提交 cb3c66e7 编写于 作者: D Damien George

stm32/adc: Increase sample time for internal sensors on L4 MCUs.

They need time (around 4us for VREFINT) to obtain accurate results.

Fixes issue #4022.
上级 3220cedc
......@@ -304,7 +304,13 @@ STATIC void adc_config_channel(ADC_HandleTypeDef *adc_handle, uint32_t channel)
sConfig.OffsetRightShift = DISABLE;
sConfig.OffsetSignedSaturation = DISABLE;
#elif defined(STM32L4)
sConfig.SamplingTime = ADC_SAMPLETIME_12CYCLES_5;
if (channel == ADC_CHANNEL_VREFINT
|| channel == ADC_CHANNEL_TEMPSENSOR
|| channel == ADC_CHANNEL_VBAT) {
sConfig.SamplingTime = ADC_SAMPLETIME_247CYCLES_5;
} else {
sConfig.SamplingTime = ADC_SAMPLETIME_12CYCLES_5;
}
sConfig.SingleDiff = ADC_SINGLE_ENDED;
sConfig.OffsetNumber = ADC_OFFSET_NONE;
sConfig.Offset = 0;
......