- Each data in `field_set` must be self-descriptive for its data type. For example 1.2f32 means a value 1.2 of float type. Without the "f" type suffix, it will be treated as type double.
- Multiple kinds of precision can be used for the `timestamp` field. Time precision can be from nanosecond (ns) to hour (h).
- The child table name is created automatically in a rule to guarantee its uniqueness. But you can configure `smlChildTableName` in taos.cfg to specify a tag value as the table names if the tag value is unique globally. For example, if a tag is called `tname` and you set `smlChildTableName=tname` in taos.cfg, when you insert `st,tname=cpu1,t1=4 c1=3 1626006833639000000`, the child table `cpu1` will be created automatically. Note that if multiple rows have the same tname but different tag_set values, the tag_set of the first row is used to create the table and the others are ignored.
- It is assumed that the order of field_set in a supertable is consistent, meaning that the first record contains all fields and subsequent records store fields in the same order. If the order is not consistent, set smlDataFormat in taos.cfg to false. Otherwise, data will be written out of order and a database error will occur.(smlDataFormat in taos.cfg default to false after version of 3.0.1.3, smlDataFormat is discarded since 3.0.3)
- It is assumed that the order of field_set in a supertable is consistent, meaning that the first record contains all fields and subsequent records store fields in the same order. If the order is not consistent, set smlDataFormat in taos.cfg to false. Otherwise, data will be written out of order and a database error will occur.(smlDataFormat in taos.cfg default to false after version of 3.0.1.3, smlDataFormat is discarded since 3.0.3.0)
:::
For more details please refer to [InfluxDB Line Protocol](https://docs.influxdata.com/influxdb/v2.0/reference/syntax/line-protocol/) and [TDengine Schemaless](/reference/schemaless/#Schemaless-Line-Protocol)
@@ -80,7 +80,7 @@ You can configure smlChildTableName in taos.cfg to specify table names, for exam
NULL.
6. For BINARY or NCHAR columns, if the length of the value provided in a data row exceeds the column type limit, the maximum length of characters allowed to be stored in the column is automatically increased (only incremented and not decremented) to ensure complete preservation of the data.
7. Errors encountered throughout the processing will interrupt the writing process and return an error code.
8. It is assumed that the order of field_set in a supertable is consistent, meaning that the first record contains all fields and subsequent records store fields in the same order. If the order is not consistent, set smlDataFormat in taos.cfg to false. Otherwise, data will be written out of order and a database error will occur.(smlDataFormat in taos.cfg default to false after version of 3.0.1.3, discarded since 3.0.3)
8. It is assumed that the order of field_set in a supertable is consistent, meaning that the first record contains all fields and subsequent records store fields in the same order. If the order is not consistent, set smlDataFormat in taos.cfg to false. Otherwise, data will be written out of order and a database error will occur.(smlDataFormat in taos.cfg default to false after version of 3.0.1.3, discarded since 3.0.3.0)
:::tip
All processing logic of schemaless will still follow TDengine's underlying restrictions on data structures, such as the total length of each row of data cannot exceed