提交 b714c1ce 编写于 作者: E ester.zhou

Update doc (14924)

Signed-off-by: Nester.zhou <ester.zhou@huawei.com>
上级 85bbe60a
......@@ -4,44 +4,45 @@
## Mini and Small Systems
### "Error: Opening COMxx: Access denied" Displayed When I Start Burning
### "Error: Opening COMxx: Access denied" Is Displayed When I Start Burning
- **Symptom**
After I click **Burn** and select a serial port, **Error: Opening COMxx: Access denied** is displayed.
**Figure 1** Access denied error
![failed-to-open-the-serial-port](figures/failed-to-open-the-serial-port.png)
- **Possible Causes**
- **Possible Causes**
The serial port is in use.
- **Solution**
1. Search for the terminal using serial-xx from the drop-down list in the **TERMINAL** panel.
**Figure 2** Checking whether the serial port is in use
![en-us_image_0000001243481989](figures/en-us_image_0000001243481989.png)
![en-us_image_0000001243481989](figures/en-us_image_0000001243481989.png)
2. Click the dustbin icon as shown below to disable the terminal using the serial port.
**Figure 3** Disabling the terminal using the serial port
![en-us_image_0000001243082093](figures/en-us_image_0000001243082093.png)
3. Click **Burn**, select the serial port, and start burning images again.
**Figure 4** Restarting the burning task
![en-us_image_0000001198322224](figures/en-us_image_0000001198322224.png)
### The Image Failed To Be Burnt
- **Symptom**
The image failed to be burnt over a serial port.
- **Possible Causes**
......@@ -87,29 +88,28 @@
>
> Hi3518E V300: **device\hisilicon\hispark_aries\sdk_liteos\uboot\out\boot\u-boot-hi3518ev300.bin**
2. Burn the U-Boot file by following the procedures for burning a U-Boot file over USB.
Select the U-Boot files of the corresponding development board for burning by referring to [Burning an Image](../quick-start/quickstart-ide-3516-burn.md).
2. Burn the U-Boot file.
Select the U-Boot files of the corresponding development board for burning. For details, see [Burning an Image](../quick-start/quickstart-ide-3516-burn.md).
3. Log in to the serial port after the burning is complete.
3. Log in to the serial port after the burning is complete.
**Figure 5** Information displayed through the serial port after the U-Boot file is burnt
**Figure 5** Information displayed through the serial port after the U-Boot file is burnt
![en-us_image_0000001243484907](figures/en-us_image_0000001243484907.png)
![en-us_image_0000001243484907](figures/en-us_image_0000001243484907.png)
### Windows-based PC Failed to Be Connected to the Board
- **Symptom**
The file image cannot be obtained after clicking **Burn** and selecting a serial port.
**Figure 6** Failed to obtain the file image due to network disconnection
![en-us_image_0000001198322428](figures/en-us_image_0000001198322428.png)
- **Possible Causes**
The board is disconnected from the Windows-based PC.
......@@ -117,23 +117,55 @@
- **Solution**
1. Check whether the network cable is properly connected.
2. Click **Windows Firewall**.
1. Make sure the network cable is properly connected.
**Figure 7** Setting the firewall
2. Click **Windows Firewall**.
**Figure 7** Setting the firewall
![en-us_image_0000001198162584](figures/en-us_image_0000001198162584.png)
3. Click **Firewall & network protection**. On the displayed page, click **Allow an app through the firewall**.
**Figure 8** Firewall & network protection
![en-us_image_0000001198323146](figures/en-us_image_0000001198323146.png)
4. Select Visual Studio Code.
**Figure 9** Selecting Visual Studio Code
![en-us_image_0000001198003232](figures/en-us_image_0000001198003232.png)
5. Select the **Private** and **Public** network access rights for Visual Studio Code.
**Figure 10** Allowing Visual Studio Code to access the network
![en-us_image_0000001243084579](figures/en-us_image_0000001243084579.png)
\ No newline at end of file
![en-us_image_0000001243084579](figures/en-us_image_0000001243084579.png)
### The Development Board Failed to Be Identified by the Burning Tool
- **Symptom**
During image burning, the burning tool displays a message indicating that no device is found.
- **Possible Causes**
The cable between the Windows computer and the development board is not connected. (The cable required varies. In this example, the USB cable is used.)
The driver corresponding to the cable between the Windows computer and the development board is not installed.
- **Solution**
1. Make sure the cable between the Windows computer and the development board is connected.
2. Open Device Manager in Windows.
3. Open the Universal Serial Bus controllers list.
4. Check whether the USB device driver has been installed. If an alarm is displayed, the driver has not been installed.
5. Depending on the Windows environment, install the desired USB device driver, such as FT23R USB UART Driver. Then try again.
6. If any other issue occurs, consult the relevant FAQ entry.
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册