1. 22 5月, 2014 1 次提交
    • G
      hwmon: (lm77) Do not preserve hysteresis when updating critical temp limit · 50bf4650
      Guenter Roeck 提交于
      Updating the hysteresis value when updating the critical temperature limit
      was following the rule of 'least surprise'. However, it had the undesirable
      side effect of changing the hysteresis for all other attributes, which
      defeats the purpose of least surprise. In addition, it could result in
      invalid hysteresis values if the resulting hysteresis was too large. In such
      cases the resulting hysteresis ended up changed anyway, which again defeats
      the purpose. So drop that code and document the new behavior.
      Reviewed-by: NJean Delvare <jdelvare@suse.de>
      Signed-off-by: NGuenter Roeck <linux@roeck-us.net>
      50bf4650
  2. 12 7月, 2005 1 次提交
  3. 22 6月, 2005 1 次提交