phy: marvell: Do not reset phy after negotiation
The patch "net: phy: do not read configuration register on reset" (sha1: a058052c) was causing regression on zynq zc702 board where Marwell 88e1118 phy was resetted after negotiation was setup. Phy reset is done pretty early in phy_connect_dev() and doens't need to be called again in phy code. Signed-off-by: NMichal Simek <michal.simek@xilinx.com>