由 Philipp Tomsich 提交于
To send a parametrized command to the PHY over MDIO, we should write the data first, the trigger the execution by the command register write. Fix the access pattern in our MDIO write routine. Apparently this doesn't really matter with the Realtek PHY on the Pine64, but other PHYs (which require more setup) will choke on the wrong order. [Andre: add commit message] Signed-off-by: NPhilipp Tomsich <philipp.tomsich@theobroma-systems.com> Signed-off-by: NAndre Przywara <andre.przywara@arm.com> Acked-by: NJagan Teki <jagan@openedev.com>
1deeecb6