1. 25 8月, 2008 9 次提交
  2. 15 8月, 2008 2 次提交
  3. 14 8月, 2008 1 次提交
  4. 13 8月, 2008 7 次提交
  5. 06 8月, 2008 3 次提交
  6. 01 8月, 2008 1 次提交
  7. 30 7月, 2008 1 次提交
  8. 28 7月, 2008 2 次提交
  9. 21 7月, 2008 2 次提交
  10. 30 9月, 2008 1 次提交
  11. 02 9月, 2008 2 次提交
  12. 01 9月, 2008 1 次提交
  13. 29 8月, 2008 1 次提交
    • C
      ALSA: oxygen: fix distorted output on AK4396-based cards · df91bc23
      Clemens Ladisch 提交于
      When changing the sample rate, the CMI8788's master clock output becomes
      unstable for a short time.  The AK4396 needs the master clock to do SPI
      writes, so writing to an AK4396 control register directly after a sample
      rate change will garble the value.  In our case, this leads to the DACs
      being misconfigured to I2S sample format, which results in a wrong
      output level and horrible distortions on samples louder than -6 dB.
      
      To fix this, we need to wait until the new master clock signal has
      become stable before doing SPI writes.
      Signed-off-by: NClemens Ladisch <clemens@ladisch.de>
      Signed-off-by: NTakashi Iwai <tiwai@suse.de>
      df91bc23
  14. 27 8月, 2008 1 次提交
  15. 26 8月, 2008 2 次提交
  16. 25 8月, 2008 1 次提交
  17. 22 8月, 2008 1 次提交
  18. 21 8月, 2008 1 次提交
  19. 17 8月, 2008 1 次提交