提交 d4c7e649 编写于 作者: H Hendrik Brueckner 提交者: Martin Schwidefsky

s390/cpum_sf: load program parameter at sampler enablement

The lpp instruction is used to place the PID of the current
task in the program-parameter (PP) register.  The register
contents is then included in the sampling data entries.

The lpp instruction loads the PP register only when at least
one sampling function is enabled.  Otherwise it is executed
as a no-op.

Linux calls lpp at context switch.  If the context switch
happens before the sampler is enabled, the PP register is
empty.  That means, the PID of the task that is sampled is
not stored in sampling data until the next context switch.

Hence, always call lpp when enabling the sampler.
Signed-off-by: NHendrik Brueckner <brueckner@linux.vnet.ibm.com>
Signed-off-by: NMartin Schwidefsky <schwidefsky@de.ibm.com>
上级 de9954b7
......@@ -144,6 +144,12 @@ struct hws_trailer_entry {
unsigned long long progusage2; /* */
} __packed;
/* Load program parameter */
static inline void lpp(void *pp)
{
asm volatile(".insn s,0xb2800000,0(%0)\n":: "a" (pp) : "memory");
}
/* Query counter information */
static inline int qctri(struct cpumf_ctr_info *info)
{
......
......@@ -848,6 +848,9 @@ static void cpumsf_pmu_enable(struct pmu *pmu)
return;
}
/* Load current program parameter */
lpp(&S390_lowcore.lpp);
debug_sprintf_event(sfdbg, 6, "pmu_enable: es=%i cs=%i ed=%i cd=%i "
"tear=%p dear=%p\n", cpuhw->lsctl.es, cpuhw->lsctl.cs,
cpuhw->lsctl.ed, cpuhw->lsctl.cd,
......