提交 22ae47e6 编写于 作者: M Mathias Nyman 提交者: Greg Kroah-Hartman

xhci: Return correct number of tranferred bytes for stalled control endpoints

Fix the xhci driver from bluntly setting the transferred length to 0 if
we get a STALL on anything else than the data stage of a control transfer.
Signed-off-by: NMathias Nyman <mathias.nyman@linux.intel.com>
Signed-off-by: NGreg Kroah-Hartman <gregkh@linuxfoundation.org>
上级 41485a90
...@@ -1934,7 +1934,7 @@ static int process_ctrl_td(struct xhci_hcd *xhci, struct xhci_td *td, ...@@ -1934,7 +1934,7 @@ static int process_ctrl_td(struct xhci_hcd *xhci, struct xhci_td *td,
td->urb->actual_length = td->urb->actual_length =
td->urb->transfer_buffer_length - td->urb->transfer_buffer_length -
EVENT_TRB_LEN(le32_to_cpu(event->transfer_len)); EVENT_TRB_LEN(le32_to_cpu(event->transfer_len));
else else if (!td->urb_length_set)
td->urb->actual_length = 0; td->urb->actual_length = 0;
return finish_td(xhci, td, event_trb, event, ep, status, false); return finish_td(xhci, td, event_trb, event, ep, status, false);
......