由 Heiko Stübner 提交于
The hym8563 datasheet describes the clock output control-bit as "when set to logic 0, the square wave output is enable, when set to logic 1, the CLKOUT output is inhibited". But in reality the setting is exactly opposite. Before now, the clock output was not really used, but on the rk3288 soc this generated clock is used to supply the temperature sensor block and the swapped bit value prevented it from working. With the corrected value, the tsadc now reports correct values. Signed-off-by: NHeiko Stuebner <heiko@sntech.de> Acked-by: NAlexandre Belloni <alexandre.belloni@free-electrons.com> Cc: Alessandro Zummo <a.zummo@towertech.it> Signed-off-by: NAndrew Morton <akpm@linux-foundation.org> Signed-off-by: NLinus Torvalds <torvalds@linux-foundation.org>
f539a8ac