1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108
# FAQ on Hi3518<a name="EN-US_TOPIC_0000001058898620"></a>

-   [What should I do when the images failed to be burnt over the selected serial port?](#section1498892119619)
-   [What should I do when Windows-based PC failed to be connected to the board?](#section8512971816)
-   [What should I do when the image failed to be burnt?](#section1767804111198)
-   [What should I do when the message indicating Python cannot be found is displayed during compilation and building?](#en-us_topic_0000001053466255_section1039835245619)
-   [What should I do when no command output is displayed?](#en-us_topic_0000001053466255_section14871149155911)

## What should I do when the images failed to be burnt over the selected serial port?<a name="section1498892119619"></a>

-   **Symptom**

    **Error: Opening COMxx: Access denied**  is displayed after clicking  **Burn**  and selecting a serial port.

    **Figure  1**  Failed to open the serial port<a name="en-us_topic_0000001053466255_fig066333283916"></a>  
    ![](figures/failed-to-open-the-serial-port.png "failed-to-open-the-serial-port")

-   **Possible Causes**

    The serial port has been used.

-   **Solutions**

1.  Search for the terminal using serial-xx from the drop-down list in the  **TERMINAL**  panel.

    **Figure  2**  Checking whether the serial port is used<a name="en-us_topic_0000001053466255_fig165994164420"></a>  
    ![](figures/checking-whether-the-serial-port-is-used.png "checking-whether-the-serial-port-is-used")

2.  Click the dustbin icon as shown in the following figure to disable the terminal using the serial port.

    **Figure  3**  Disabling the terminal using the serial port<a name="en-us_topic_0000001053466255_fig7911282453"></a>  
    ![](figures/disabling-the-terminal-using-the-serial-port.png "disabling-the-terminal-using-the-serial-port")

3.  Click  **Burn**, select the serial port, and start burning images again.

    **Figure  4**  Restarting burning<a name="en-us_topic_0000001053466255_fig1138624316485"></a>  
    

    ![](figures/changjian1.png)


## What should I do when Windows-based PC failed to be connected to the board?<a name="section8512971816"></a>

-   **Symptom**

    The file image cannot be obtained after clicking  **Burn**  and selecting a serial port.

    **Figure  5**  Failed to obtain the image file due to unavailable connection<a name="en-us_topic_0000001053466255_fig5218920223"></a>  
    ![](figures/failed-to-obtain-the-image-file-due-to-unavailable-connection.png "failed-to-obtain-the-image-file-due-to-unavailable-connection")

-   **Possible Causes**

    The board is disconnected from the Windows-based PC.

    Windows Firewall does not allow Visual Studio Code to access the network.

-   **Solutions**

1.  Check whether the network cable is properly connected.
2.  Click  **Windows Firewall**.

    **Figure  6**  Network and firewall setting<a name="en-us_topic_0000001053466255_fig62141417794"></a>  
    ![](figures/network-and-firewall-setting.png "network-and-firewall-setting")

3.  Click  **Firewall & network protection**, and on the displayed page, click  **Allow applications to communicate through Windows Firewall**.

    **Figure  7**  Firewall and network protection<a name="en-us_topic_0000001053466255_fig20703151111116"></a>  
    ![](figures/firewall-and-network-protection.png "firewall-and-network-protection")

4.  Select the Visual Studio Code application

    **Figure  8**  Selecting the Visual Studio Code application<a name="en-us_topic_0000001053466255_fig462316612165"></a>  
    ![](figures/selecting-the-visual-studio-code-application.png "selecting-the-visual-studio-code-application")

5.  Select the  **Private**  and  **Public**  network access rights for the Visual Studio Code application.

    **Figure  9**  Allowing the Visual Studio Code application to access the network<a name="en-us_topic_0000001053466255_fig132725269184"></a>  
    ![](figures/allowing-the-visual-studio-code-application-to-access-the-network.png "allowing-the-visual-studio-code-application-to-access-the-network")


## What should I do when the image failed to be burnt?<a name="section1767804111198"></a>

-   **Symptom**

    The burning status is not displayed after clicking  **Burn**  and selecting a serial port.

-   **Possible Causes**

    The IDE is not restarted after the DevEco plug-in is installed.

-   **Solutions**

    Restart the IDE.


## What should I do when the message indicating Python cannot be found is displayed during compilation and building?<a name="en-us_topic_0000001053466255_section1039835245619"></a>

-   **Symptom**

    ![](figures/en-us_image_0000001058781525.png)


-   **Possible Cause 1**

    Python is not installed.

-   **Solutions**

N
NEEN 已提交
109
    Install the Python environment by referring to  [Installing a Python Environment](basic-os-environment-setup.md#section11255767343).
Y
yangni 已提交
110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162

-   **Possible Cause 2**

    ![](figures/en-us_image_0000001058939672.png)

-   **Solutions**

    Run the following commands:

    ```
    # cd /usr/bin/
    # which python3
    # ln -s /usr/local/bin/python3 python
    # python --version
    ```

    Example:

    ![](figures/en-us_image_0000001058781464.png)


## What should I do when no command output is displayed?<a name="en-us_topic_0000001053466255_section14871149155911"></a>

-   **Symptom**

    The serial port shows that the connection has been established. After the board is restarted, nothing is displayed when you press  **Enter**.

-   **Possible Cause 1**

    The serial port is connected incorrectly.

-   **Solutions**

    Change the serial port number.

    Start  **Device Manager**  to check whether the serial port connected to the board is the same as that connected to the terminal device. If the serial ports are different, perform step  [1](developing-the-first-example-program-running-on-hi3518.md#li744118533233)  in the  **Running an Image**  section to change the serial port number.


-   **Possible Cause 2**

    The U-boot of the board is damaged.

-   **Solutions**

    Burn the U-boot.

    If the fault persists after you perform the preceding operations, the U-boot of the board may be damaged. You can burn the U-boot by performing the following steps:


1.  Obtain the U-boot file.

    >![](public_sys-resources/icon-notice.gif) **NOTICE:** 
    >The U-boot file of the two boards can be obtained from the following paths, respectively.
N
NEEN 已提交
163 164
    >Hi3516D V300:  **device\\hisilicon\\hispark\_taurus\\sdk\_liteos\\uboot\\out\\boot\\u-boot-hi3516dv300.bin**
    >Hi3518E V300:  **device\\hisilicon\\hispark\_aries\\sdk\_liteos\\uboot\\out\\boot\\u-boot-hi3518ev300.bin**
Y
yangni 已提交
165 166 167 168 169 170 171 172 173 174

2.  Burn the U-boot file by following the procedures for burning a U-boot file over USB.

    Select the U-boot files of corresponding development boards for burning by referring to  [Programming Flash Memory on the Hi3516](https://device.harmonyos.com/en/docs/ide/user-guides/hi3516_upload-0000001052148681)/[Programming Flash Memory on the Hi3518](https://device.harmonyos.com/en/docs/ide/user-guides/hi3518_upload-0000001057313128)

3.  Log in to the serial port after the burning is complete.

    ![](figures/en-us_image_0000001058719409.png)