1. 03 2月, 2012 2 次提交
    • A
      rbd: fix safety of rbd_put_client() · d23a4b3f
      Alex Elder 提交于
      The rbd_client structure uses a kref to arrange for cleaning up and
      freeing an instance when its last reference is dropped.  The cleanup
      routine is rbd_client_release(), and one of the things it does is
      delete the rbd_client from rbd_client_list.  It acquires node_lock
      to do so, but the way it is done is still not safe.
      
      The problem is that when attempting to reuse an existing rbd_client,
      the structure found might already be in the process of getting
      destroyed and cleaned up.
      
      Here's the scenario, with "CLIENT" representing an existing
      rbd_client that's involved in the race:
      
       Thread on CPU A                | Thread on CPU B
       ---------------                | ---------------
       rbd_put_client(CLIENT)         | rbd_get_client()
         kref_put()                   |   (acquires node_lock)
           kref->refcount becomes 0   |   __rbd_client_find() returns CLIENT
           calls rbd_client_release() |   kref_get(&CLIENT->kref);
                                      |   (releases node_lock)
             (acquires node_lock)     |
             deletes CLIENT from list | ...and starts using CLIENT...
             (releases node_lock)     |
             and frees CLIENT         | <-- but CLIENT gets freed here
      
      Fix this by having rbd_put_client() acquire node_lock.  The result
      could still be improved, but at least it avoids this problem.
      Signed-off-by: NAlex Elder <elder@dreamhost.com>
      Signed-off-by: NSage Weil <sage@newdream.net>
      d23a4b3f
    • A
      rbd: fix a memory leak in rbd_get_client() · 97bb59a0
      Alex Elder 提交于
      If an existing rbd client is found to be suitable for use in
      rbd_get_client(), the rbd_options structure is not being
      freed as it should.  Fix that.
      Signed-off-by: NAlex Elder <elder@dreamhost.com>
      Signed-off-by: NSage Weil <sage@newdream.net>
      97bb59a0
  2. 02 2月, 2012 4 次提交
  3. 01 2月, 2012 8 次提交
  4. 31 1月, 2012 3 次提交
    • T
      RDMA/nes: Copyright update · c5488c57
      Tatyana Nikolova 提交于
      Update copyright information in the source files.
      Signed-off-by: NTatyana Nikolova <Tatyana.E.Nikolova@intel.com>
      Signed-off-by: NFaisal Latif <Faisal.Latif@intel.com>
      Signed-off-by: NRoland Dreier <roland@purestorage.com>
      c5488c57
    • J
      IB/mlx4: pass SMP vendor-specific attribute MADs to firmware · a6f7feae
      Jack Morgenstein 提交于
      In the current code, vendor-specific MADs (e.g with the FDR-10
      attribute) are silently dropped by the driver, resulting in timeouts
      at the sending side and inability to query/configure the relevant
      feature.  However, the ConnectX firmware is able to handle such MADs.
      For unsupported attributes, the firmware returns a GET_RESPONSE MAD
      containing an error status.
      
      For example, for a FDR-10 node with LID 11:
      
          # ibstat mlx4_0 1
      
          CA: 'mlx4_0'
          Port 1:
          State: Active
          Physical state: LinkUp
          Rate: 40 (FDR10)
          Base lid: 11
          LMC: 0
          SM lid: 24
          Capability mask: 0x02514868
          Port GUID: 0x0002c903002e65d1
          Link layer: InfiniBand
      
      Extended Port Query (EPI) vendor mad timeouts before the patch:
      
          # smpquery MEPI 11 -d
      
          ibwarn: [4196] smp_query_via: attr 0xff90 mod 0x0 route Lid 11
          ibwarn: [4196] _do_madrpc: retry 1 (timeout 1000 ms)
          ibwarn: [4196] _do_madrpc: retry 2 (timeout 1000 ms)
          ibwarn: [4196] _do_madrpc: timeout after 3 retries, 3000 ms
          ibwarn: [4196] mad_rpc: _do_madrpc failed; dport (Lid 11)
          smpquery: iberror: [pid 4196] main: failed: operation EPI: ext port info query failed
      
      EPI query works OK with the patch:
      
          # smpquery MEPI 11 -d
      
          ibwarn: [6548] smp_query_via: attr 0xff90 mod 0x0 route Lid 11
          ibwarn: [6548] mad_rpc: data offs 64 sz 64
          mad data
          0000 0000 0000 0001 0000 0001 0000 0001
          0000 0000 0000 0000 0000 0000 0000 0000
          0000 0000 0000 0000 0000 0000 0000 0000
          0000 0000 0000 0000 0000 0000 0000 0000
          # Ext Port info: Lid 11 port 0
          StateChangeEnable:...............0x00
          LinkSpeedSupported:..............0x01
          LinkSpeedEnabled:................0x01
          LinkSpeedActive:.................0x01
      Signed-off-by: NJack Morgenstein <jackm@mellanox.com>
      Signed-off-by: NOr Gerlitz <ogerlitz@mellanox.com>
      Acked-by: NIra Weiny <weiny2@llnl.gov>
      Cc: <stable@vger.kernel.org>
      Signed-off-by: NRoland Dreier <roland@purestorage.com>
      a6f7feae
    • S
      firewire: ohci: disable MSI on Ricoh controllers · 320cfa6c
      Stefan Richter 提交于
      The PCIe device
      
          FireWire (IEEE 1394) [0c00]: Ricoh Co Ltd FireWire Host Controller
          [1180:e832] (prog-if 10 [OHCI])
      
      is unable to access attached FireWire devices when MSI is enabled but
      works if MSI is disabled.
      http://www.mail-archive.com/alsa-user@lists.sourceforge.net/msg28251.html
      
      Hence add the "disable MSI" quirks flag for this device, or in fact for
      safety and simplicity for all current (R5U230, R5U231, R5U240) and
      future Ricoh PCIe 1394 controllers.
      Reported-by: NStefan Thomas <kontrapunktstefan@googlemail.com>
      Cc: 2.6.36+ <stable@vger.kernel.org>
      Signed-off-by: NStefan Richter <stefanr@s5r6.in-berlin.de>
      320cfa6c