- 25 10月, 2011 3 次提交
-
-
由 Guenter Roeck 提交于
At least one PMBus chip supports peak attributes for READ_TEMPERATURE2. Add virtual registers to be able to report it to the user. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
由 Guenter Roeck 提交于
Driver remove functions have an error return value, but rarely return an error in practice. If a driver does return an error from its remove function, the driver won't be unloaded and is expected to stay alive. pmbus_do_remove() is defined as returning an int, but always returns 0 (no error). Calling code passes that return value on to high level driver remove functions, but does not evaluate it and removes driver data even if pmbus_do_remove() returned an error (which it in practice never does). Even if this code could never cause a real problem, it is nevertheless conceptually wrong. To reduce confusion and simplify the code, change pmbus_do_remove() to be a void function, and have PMBus client drivers always return zero in their driver remove functions. Reported-by: NJean Delvare <khali@linux-fr.org> Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Acked-by: NJean Delvare <khali@linux-fr.org>
-
由 Guenter Roeck 提交于
Return values for functions reading/writing manufacturer specific registers are poorly explained. Add comments to improve documentation. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Acked-by: NJean Delvare <khali@linux-fr.org>
-
- 12 8月, 2011 1 次提交
-
-
由 Guenter Roeck 提交于
With virtual pages and to be able to handle more chips, it is necessary to virtualise pmbus_write_byte(). Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
- 29 7月, 2011 6 次提交
-
-
由 Guenter Roeck 提交于
PMBus client driver supporting National Semiconductor LM25066, LM5064, and LM5066. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
由 Guenter Roeck 提交于
Most PMBus devices provide manufacturer specific commands to read low and/or high peak values for some or all of its sensors. To support providing those values as lowest/highest attributes to the user, introduce virtual PMBus commands. Those commands reside outside the normal command set and have to be implemented in device specific code, which map the virtual commands to device specific commands. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
由 Guenter Roeck 提交于
Some PMBus chips have non-standard sensor registers. An easy way to support such sensors is to introduce virtual pages and map the non-standard registers into standard registers on an extra page. For this to work, the code verifying if the configured number of pages exists has to be removed. Since a wrong number of pages can only be configured in a front-end driver, this should not have a practical impact since the resulting errors should be found during development and testing. Also, functions to read the chip status while checking if a command register exists must be modified to no longer set the page register before reading the status, since the physical page associated with the checked register may not exist. This does not make a functional difference since the page was already set when the attempt to read the register was made. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
由 Guenter Roeck 提交于
Some PMBus devices use non-standard registers for some of the sensors and/or limits. To support such devices, add code to support reading and writing of word size registers in device specific code. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
由 Guenter Roeck 提交于
In VID mode, output voltages are measured and reported as VID values, and have to be converted to voltages using VID conversion tables or functions. Support is added for VR11 only at this time. This patch enables support for PMBus devices supporting VID VR11 based output voltage selection such as NCP4200 and NCP4208. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
由 Guenter Roeck 提交于
Since the number of PMBus drivers is getting large, move them into directory drivers/hwmon/pmbus to improve readability and scalability. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
- 19 5月, 2011 1 次提交
-
-
由 Guenter Roeck 提交于
Some devices use non-standard registers to access various functionality. This does not only affect status registers, but other registers as well. Rename local get_status function to get_byte_data to reflect this requirement. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NTom Grennan <tom.grennan@ericsson.com>
-
- 15 3月, 2011 1 次提交
-
-
由 Guenter Roeck 提交于
This driver adds support for hardware monitoring features of various PMBus devices. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Acked-by: NJonathan Cameron <jic23@cam.ac.uk>
-