1. 09 6月, 2014 10 次提交
  2. 08 6月, 2014 8 次提交
  3. 06 6月, 2014 8 次提交
  4. 05 6月, 2014 6 次提交
  5. 29 5月, 2014 4 次提交
  6. 24 5月, 2014 1 次提交
    • S
      net-next:v4: Add support to configure SR-IOV VF minimum and maximum Tx rate through ip tool. · ed616689
      Sucheta Chakraborty 提交于
      o min_tx_rate puts lower limit on the VF bandwidth. VF is guaranteed
        to have a bandwidth of at least this value.
        max_tx_rate puts cap on the VF bandwidth. VF can have a bandwidth
        of up to this value.
      
      o A new handler set_vf_rate for attr IFLA_VF_RATE has been introduced
        which takes 4 arguments:
        netdev, VF number, min_tx_rate, max_tx_rate
      
      o ndo_set_vf_rate replaces ndo_set_vf_tx_rate handler.
      
      o Drivers that currently implement ndo_set_vf_tx_rate should now call
        ndo_set_vf_rate instead and reject attempt to set a minimum bandwidth
        greater than 0 for IFLA_VF_TX_RATE when IFLA_VF_RATE is not yet
        implemented by driver.
      
      o If user enters only one of either min_tx_rate or max_tx_rate, then,
        userland should read back the other value from driver and set both
        for IFLA_VF_RATE.
        Drivers that have not yet implemented IFLA_VF_RATE should always
        return min_tx_rate as 0 when read from ip tool.
      
      o If both IFLA_VF_TX_RATE and IFLA_VF_RATE options are specified, then
        IFLA_VF_RATE should override.
      
      o Idea is to have consistent display of rate values to user.
      
      o Usage example: -
      
        ./ip link set p4p1 vf 0 rate 900
      
        ./ip link show p4p1
        32: p4p1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode
        DEFAULT qlen 1000
          link/ether 00:0e:1e:08:b0:f0 brd ff:ff:ff:ff:ff:ff
          vf 0 MAC 3e:a0:ca:bd:ae:5a, tx rate 900 (Mbps), max_tx_rate 900Mbps
          vf 1 MAC f6:c6:7c:3f:3d:6c
          vf 2 MAC 56:32:43:98:d7:71
          vf 3 MAC d6:be:c3:b5:85:ff
          vf 4 MAC ee:a9:9a:1e:19:14
          vf 5 MAC 4a:d0:4c:07:52:18
          vf 6 MAC 3a:76:44:93:62:f9
          vf 7 MAC 82:e9:e7:e3:15:1a
      
        ./ip link set p4p1 vf 0 max_tx_rate 300 min_tx_rate 200
      
        ./ip link show p4p1
        32: p4p1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode
        DEFAULT qlen 1000
          link/ether 00:0e:1e:08:b0:f0 brd ff:ff:ff:ff:ff:ff
          vf 0 MAC 3e:a0:ca:bd:ae:5a, tx rate 300 (Mbps), max_tx_rate 300Mbps,
          min_tx_rate 200Mbps
          vf 1 MAC f6:c6:7c:3f:3d:6c
          vf 2 MAC 56:32:43:98:d7:71
          vf 3 MAC d6:be:c3:b5:85:ff
          vf 4 MAC ee:a9:9a:1e:19:14
          vf 5 MAC 4a:d0:4c:07:52:18
          vf 6 MAC 3a:76:44:93:62:f9
          vf 7 MAC 82:e9:e7:e3:15:1a
      
        ./ip link set p4p1 vf 0 max_tx_rate 600 rate 300
      
        ./ip link show p4p1
        32: p4p1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode
        DEFAULT qlen 1000
          link/ether 00:0e:1e:08:b0:f brd ff:ff:ff:ff:ff:ff
          vf 0 MAC 3e:a0:ca:bd:ae:5, tx rate 600 (Mbps), max_tx_rate 600Mbps,
          min_tx_rate 200Mbps
          vf 1 MAC f6:c6:7c:3f:3d:6c
          vf 2 MAC 56:32:43:98:d7:71
          vf 3 MAC d6:be:c3:b5:85:ff
          vf 4 MAC ee:a9:9a:1e:19:14
          vf 5 MAC 4a:d0:4c:07:52:18
          vf 6 MAC 3a:76:44:93:62:f9
          vf 7 MAC 82:e9:e7:e3:15:1a
      Signed-off-by: NSucheta Chakraborty <sucheta.chakraborty@qlogic.com>
      Signed-off-by: NDavid S. Miller <davem@davemloft.net>
      ed616689
  7. 23 5月, 2014 1 次提交
  8. 21 5月, 2014 2 次提交