      ALSA: hda - Fix inconsistent pin states after resume · 31614bb8
      Takashi Iwai 提交于
      The commit [26a6cb6c: ALSA: hda - Implement a poll loop for jacks as a
      module parameter] introduced the polling jack detection code, but it
      also moved the call of snd_hda_jack_set_dirty_all() in the resume path
      after resume/init ops call.  This caused a regression when the jack
      state has been changed during power-down (e.g. in the power save
      mode).  Since the driver doesn't probe the new jack state but keeps
      using the cached value due to no dirty flag, the pin state remains
      also as if the jack is still plugged.
      
      The fix is simply moving snd_hda_jack_set_dirty_all() to the original
      position.
      Reported-by: NManolo Díaz <diaz.manolo@gmail.com>
      Signed-off-by: NTakashi Iwai <tiwai@suse.de>
      31614bb8