提交 ff0b8597 编写于 作者: B Bryan O'Sullivan 提交者: Roland Dreier

IB/ipath: add serial number to hardware freeze error message

Also added the word "Hardware" after "Fatal" to make it more obvious
that it's hardware, not software.
Signed-off-by: NBryan O'Sullivan <bryan.osullivan@qlogic.com>
Signed-off-by: NRoland Dreier <rolandd@cisco.com>
上级 525d0ca1
......@@ -461,8 +461,9 @@ static void ipath_ht_handle_hwerrors(struct ipath_devdata *dd, char *msg,
* times.
*/
if (dd->ipath_flags & IPATH_INITTED) {
ipath_dev_err(dd, "Fatal Error (freeze "
"mode), no longer usable\n");
ipath_dev_err(dd, "Fatal Hardware Error (freeze "
"mode), no longer usable, SN %.16s\n",
dd->ipath_serial);
isfatal = 1;
}
*dd->ipath_statusp &= ~IPATH_STATUS_IB_READY;
......
......@@ -363,8 +363,9 @@ static void ipath_pe_handle_hwerrors(struct ipath_devdata *dd, char *msg,
* and we get here multiple times
*/
if (dd->ipath_flags & IPATH_INITTED) {
ipath_dev_err(dd, "Fatal Error (freeze "
"mode), no longer usable\n");
ipath_dev_err(dd, "Fatal Hardware Error (freeze "
"mode), no longer usable, SN %.16s\n",
dd->ipath_serial);
isfatal = 1;
}
/*
......