clk: ux500: fix erroneous bit assignment
Due to a typo or similar, the peripheral group 2 clock 11 gate was set to bit 1 instead of bit 11. We need to fix this to be able to set the correct enable bit in the device tree: when trying to correct the bit assignment in the device tree, the system would hang. Cc: Mike Turquette <mturquette@linaro.org> Acked-by: NLee Jones <lee.jones@linaro.org> Signed-off-by: NLinus Walleij <linus.walleij@linaro.org>