spi/pl022: move device disable to workqueue thread
Moves the disabling of the device and clocks to the same thread in which the device and clocks are enabled. This avoids SMP issues where the device can be enabled for a transfer by one thread and then disabled by the completion of the previous transfer in another thread. Reviewed-by: NViresh Kumar <viresh.kumar@st.com> Signed-off-by: NChris Blair <chris.blair@stericsson.com> Signed-off-by: NLinus Walleij <linus.walleij@linaro.org>