提交 c34a61b4 编写于 作者: A Anton Vorontsov

ab8500_fg: Get rid of 'struct battery_type'

The struct is duplicated, plus causes the following flood:

  CC      drivers/power/ab8500_fg.o
ab8500_fg.c: In function ‘ab8500_fg_get_ext_psy_data’:
b8500_fg.c:2081:8: warning: assignment from incompatible pointer type [enabled by default]
Signed-off-by: NAnton Vorontsov <anton.vorontsov@linaro.org>
上级 450ceb2b
......@@ -2077,7 +2077,8 @@ static int ab8500_fg_get_ext_psy_data(struct device *dev, void *data)
switch (ext->type) {
case POWER_SUPPLY_TYPE_BATTERY:
if (!di->flags.batt_id_received) {
const struct battery_type *b;
const struct abx500_battery_type *b;
b = &(di->bat->bat_type[di->bat->batt_id]);
di->flags.batt_id_received = true;
......
......@@ -312,64 +312,6 @@ struct ab8500_maxim_parameters {
int charger_curr_step;
};
/**
* struct battery_type - different batteries supported
* @name: battery technology
* @resis_high: battery upper resistance limit
* @resis_low: battery lower resistance limit
* @charge_full_design: Maximum battery capacity in mAh
* @nominal_voltage: Nominal voltage of the battery in mV
* @termination_vol: max voltage upto which battery can be charged
* @termination_curr battery charging termination current in mA
* @recharge_vol battery voltage limit that will trigger a new
* full charging cycle in the case where maintenan-
* -ce charging has been disabled
* @normal_cur_lvl: charger current in normal state in mA
* @normal_vol_lvl: charger voltage in normal state in mV
* @maint_a_cur_lvl: charger current in maintenance A state in mA
* @maint_a_vol_lvl: charger voltage in maintenance A state in mV
* @maint_a_chg_timer_h: charge time in maintenance A state
* @maint_b_cur_lvl: charger current in maintenance B state in mA
* @maint_b_vol_lvl: charger voltage in maintenance B state in mV
* @maint_b_chg_timer_h: charge time in maintenance B state
* @low_high_cur_lvl: charger current in temp low/high state in mA
* @low_high_vol_lvl: charger voltage in temp low/high state in mV'
* @battery_resistance: battery inner resistance in mOhm.
* @n_r_t_tbl_elements: number of elements in r_to_t_tbl
* @r_to_t_tbl: table containing resistance to temp points
* @n_v_cap_tbl_elements: number of elements in v_to_cap_tbl
* @v_to_cap_tbl: Voltage to capacity (in %) table
* @n_batres_tbl_elements number of elements in the batres_tbl
* @batres_tbl battery internal resistance vs temperature table
*/
struct battery_type {
int name;
int resis_high;
int resis_low;
int charge_full_design;
int nominal_voltage;
int termination_vol;
int termination_curr;
int recharge_vol;
int normal_cur_lvl;
int normal_vol_lvl;
int maint_a_cur_lvl;
int maint_a_vol_lvl;
int maint_a_chg_timer_h;
int maint_b_cur_lvl;
int maint_b_vol_lvl;
int maint_b_chg_timer_h;
int low_high_cur_lvl;
int low_high_vol_lvl;
int battery_resistance;
int n_temp_tbl_elements;
struct res_to_temp *r_to_t_tbl;
int n_v_cap_tbl_elements;
struct v_to_cap *v_to_cap_tbl;
int n_batres_tbl_elements;
struct batres_vs_temp *batres_tbl;
};
/**
* struct ab8500_bm_capacity_levels - ab8500 capacity level data
* @critical: critical capacity level in percent
......@@ -453,7 +395,6 @@ struct ab8500_bm_data {
int gnd_lift_resistance;
const struct ab8500_maxim_parameters *maxi;
const struct ab8500_bm_capacity_levels *cap_levels;
const struct battery_type *bat_type;
const struct ab8500_bm_charger_parameters *chg_params;
const struct ab8500_fg_parameters *fg_params;
};
......