提交 afe86286 编写于 作者: B Bruno Randolf 提交者: John W. Linville

ath5k: run NF calibration only every 60 seconds

Since NF calibration interferes with TX and RX and also has been the cause of
other problems (when it's run concurrently with ath5k_reset) we want to run it
less often - every 60 seconds for now.
Signed-off-by: NBruno Randolf <br1@einfach.org>
Signed-off-by: NJohn W. Linville <linville@tuxdriver.com>
上级 0e8e02dd
......@@ -204,6 +204,7 @@
#define AR5K_TUNE_TPC_TXPOWER false
#define ATH5K_TUNE_CALIBRATION_INTERVAL_FULL 10000 /* 10 sec */
#define ATH5K_TUNE_CALIBRATION_INTERVAL_ANI 1000 /* 1 sec */
#define ATH5K_TUNE_CALIBRATION_INTERVAL_NF 60000 /* 60 sec */
#define AR5K_INIT_CARR_SENSE_EN 1
......@@ -1118,6 +1119,7 @@ struct ath5k_hw {
/* Calibration timestamp */
unsigned long ah_cal_next_full;
unsigned long ah_cal_next_ani;
unsigned long ah_cal_next_nf;
/* Calibration mask */
u8 ah_cal_mask;
......
......@@ -2803,14 +2803,16 @@ ath5k_tasklet_calibrate(unsigned long data)
ieee80211_frequency_to_channel(
sc->curchan->center_freq));
/* TODO: We don't need to run noise floor calibration as often
* as I/Q calibration.*/
/* Noise floor calibration interrupts rx/tx path while I/Q calibration
* doesn't. Stop queues so that calibration doesn't interfere with tx */
ieee80211_stop_queues(sc->hw);
ath5k_hw_update_noise_floor(ah);
ieee80211_wake_queues(sc->hw);
* doesn't. We stop the queues so that calibration doesn't interfere
* with TX and don't run it as often */
if (time_is_before_eq_jiffies(ah->ah_cal_next_nf)) {
ah->ah_cal_next_nf = jiffies +
msecs_to_jiffies(ATH5K_TUNE_CALIBRATION_INTERVAL_NF);
ieee80211_stop_queues(sc->hw);
ath5k_hw_update_noise_floor(ah);
ieee80211_wake_queues(sc->hw);
}
ah->ah_cal_mask &= ~AR5K_CALIBRATION_FULL;
}
......@@ -2931,6 +2933,8 @@ ath5k_reset(struct ath5k_softc *sc, struct ieee80211_channel *chan)
ah->ah_cal_next_full = jiffies;
ah->ah_cal_next_ani = jiffies;
ah->ah_cal_next_nf = jiffies;
/*
* Change channels and update the h/w rate map if we're switching;
* e.g. 11a to 11b/g.
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册