提交 61c04572 编写于 作者: L Linus Torvalds

Merge branch 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux

Pull thermal fixes from Zhang Rui:

 - Fix cpu_cooling to have separate thermal_cooling_device_ops
   structures for cpus with and without power model, to avoid NULL
   dereference in cpufreq_state2power.  From Brendan Jackman.

 - Fix a possible NULL dereference in imx_thermal driver.  From Corentin
   LABBE.

 - Another two trivial fixes, one typo fix and one deleting module
   owner.  From Caesar Wang and Markus Elfring.

* 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux:
  thermal: imx: fix a possible NULL dereference
  thermal: trivial: fix the typo
  Thermal-INT3406: Delete owner assignment
  thermal: cpu_cooling: Fix NULL dereference in cpufreq_state2power
......@@ -62,7 +62,7 @@ For more examples of cooling devices, refer to the example sections below.
Required properties:
- #cooling-cells: Used to provide cooling device specific information
Type: unsigned while referring to it. Must be at least 2, in order
Size: one cell to specify minimum and maximum cooling state used
Size: one cell to specify minimum and maximum cooling state used
in the reference. The first cell is the minimum
cooling state requested and the second cell is
the maximum cooling state requested in the reference.
......@@ -119,7 +119,7 @@ Required properties:
Optional property:
- contribution: The cooling contribution to the thermal zone of the
Type: unsigned referred cooling device at the referred trip point.
Size: one cell The contribution is a ratio of the sum
Size: one cell The contribution is a ratio of the sum
of all cooling contributions within a thermal zone.
Note: Using the THERMAL_NO_LIMIT (-1UL) constant in the cooling-device phandle
......@@ -145,7 +145,7 @@ Required properties:
Size: one cell
- thermal-sensors: A list of thermal sensor phandles and sensor specifier
Type: list of used while monitoring the thermal zone.
Type: list of used while monitoring the thermal zone.
phandles + sensor
specifier
......@@ -473,7 +473,7 @@ thermal-zones {
<&adc>; /* pcb north */
/* hotspot = 100 * bandgap - 120 * adc + 484 */
coefficients = <100 -120 484>;
coefficients = <100 -120 484>;
trips {
...
......@@ -502,7 +502,7 @@ from the ADC sensor. The binding would be then:
thermal-sensors = <&adc>;
/* hotspot = 1 * adc + 6000 */
coefficients = <1 6000>;
coefficients = <1 6000>;
(d) - Board thermal
......
......@@ -740,12 +740,22 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev,
}
/* Bind cpufreq callbacks to thermal cooling device ops */
static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
.get_max_state = cpufreq_get_max_state,
.get_cur_state = cpufreq_get_cur_state,
.set_cur_state = cpufreq_set_cur_state,
};
static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
.get_max_state = cpufreq_get_max_state,
.get_cur_state = cpufreq_get_cur_state,
.set_cur_state = cpufreq_set_cur_state,
.get_requested_power = cpufreq_get_requested_power,
.state2power = cpufreq_state2power,
.power2state = cpufreq_power2state,
};
/* Notifier for cpufreq policy change */
static struct notifier_block thermal_cpufreq_notifier_block = {
.notifier_call = cpufreq_thermal_notifier,
......@@ -795,6 +805,7 @@ __cpufreq_cooling_register(struct device_node *np,
struct cpumask temp_mask;
unsigned int freq, i, num_cpus;
int ret;
struct thermal_cooling_device_ops *cooling_ops;
cpumask_and(&temp_mask, clip_cpus, cpu_online_mask);
policy = cpufreq_cpu_get(cpumask_first(&temp_mask));
......@@ -850,10 +861,6 @@ __cpufreq_cooling_register(struct device_node *np,
cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
if (capacitance) {
cpufreq_cooling_ops.get_requested_power =
cpufreq_get_requested_power;
cpufreq_cooling_ops.state2power = cpufreq_state2power;
cpufreq_cooling_ops.power2state = cpufreq_power2state;
cpufreq_dev->plat_get_static_power = plat_static_func;
ret = build_dyn_power_table(cpufreq_dev, capacitance);
......@@ -861,6 +868,10 @@ __cpufreq_cooling_register(struct device_node *np,
cool_dev = ERR_PTR(ret);
goto free_table;
}
cooling_ops = &cpufreq_power_cooling_ops;
} else {
cooling_ops = &cpufreq_cooling_ops;
}
ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
......@@ -885,7 +896,7 @@ __cpufreq_cooling_register(struct device_node *np,
cpufreq_dev->id);
cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
&cpufreq_cooling_ops);
cooling_ops);
if (IS_ERR(cool_dev))
goto remove_idr;
......
......@@ -471,8 +471,6 @@ MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
static int imx_thermal_probe(struct platform_device *pdev)
{
const struct of_device_id *of_id =
of_match_device(of_imx_thermal_match, &pdev->dev);
struct imx_thermal_data *data;
struct regmap *map;
int measure_freq;
......@@ -490,7 +488,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
}
data->tempmon = map;
data->socdata = of_id->data;
data->socdata = of_device_get_match_data(&pdev->dev);
/* make sure the IRQ flag is clear before enabling irq on i.MX6SX */
if (data->socdata->version == TEMPMON_IMX6SX) {
......
......@@ -225,7 +225,6 @@ static struct platform_driver int3406_thermal_driver = {
.remove = int3406_thermal_remove,
.driver = {
.name = "int3406 thermal",
.owner = THIS_MODULE,
.acpi_match_table = int3406_thermal_match,
},
};
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册