e1000e: 82579 do not gate auto config of PHY by hardware during nominal use
For non-managed versions of 82579, set the bit that prevents the hardware from automatically configuring the PHY after resets only when the driver performs a reset, clear the bit after resets. This is so the hardware can configure the PHY automatically when the part is reset in a manner that is not controlled by the driver (e.g. in a virtual environment via PCI FLR) otherwise the PHY will be mis-configured causing issues such as failing to link at 1000Mbps. For managed versions of 82579, keep the previous behavior since the manageability firmware will handle the PHY configuration. Signed-off-by: NBruce Allan <bruce.w.allan@intel.com> Tested-by: NJeff Pieper <jeffrey.e.pieper@intel.com> Signed-off-by: NJeff Kirsher <jeffrey.t.kirsher@intel.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>