gianfar: Implement workaround for eTSEC-A002 erratum
MPC8313ECE says: "If the controller receives a 1- or 2-byte frame (such as an illegal runt packet or a packet with RX_ER asserted) before GRS is asserted and does not receive any other frames, the controller may fail to set GRSC even when the receive logic is completely idle. Any subsequent receive frame that is larger than two bytes will reset the state so the graceful stop can complete. A MAC receiver (Rx) reset will also reset the state." This patch implements the proposed workaround: "If IEVENT[GRSC] is still not set after the timeout, read the eTSEC register at offset 0xD1C. If bits 7-14 are the same as bits 23-30, the eTSEC Rx is assumed to be idle and the Rx can be safely reset. If the register fields are not equal, wait for another timeout period and check again." Signed-off-by: NAnton Vorontsov <avorontsov@mvista.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
Showing
想要评论请 注册 或 登录