提交 414128bd 编写于 作者: J Jan Beulich 提交者: Ingo Molnar

x86: Increase timeout for EHCI debug port reset completion in early printk

On one of my systems, several thousand iterations are needed before
CMD_RESET can be observed clear after setting it. Using a much
higher value here obviously cannot hurt.
Signed-off-by: NJan Beulich <jbeulich@novell.com>
Cc: Yinghai Lu <yhlu.kernel@gmail.com>
LKML-Reference: <4AA0E85D02000078000136F9@vpn.id2.novell.com>
Signed-off-by: NIngo Molnar <mingo@elte.hu>
上级 4fe48782
......@@ -624,7 +624,7 @@ static int __init ehci_setup(void)
return -1;
}
loop = 10;
loop = 100000;
/* Reset the EHCI controller */
cmd = readl(&ehci_regs->command);
cmd |= CMD_RESET;
......