提交 2aa70f86 编写于 作者: G Geert Uytterhoeven 提交者: David S. Miller

net: smsc911x: Quieten netif during suspend

If the network interface is kept running during suspend, the net core
may call net_device_ops.ndo_start_xmit() while the Ethernet device is
still suspended, which may lead to a system crash.

E.g. on sh73a0/kzm9g and r8a73a4/ape6evm, the external Ethernet chip is
driven by a PM controlled clock.  If the Ethernet registers are accessed
while the clock is not running, the system will crash with an imprecise
external abort.

As this is a race condition with a small time window, it is not so easy
to trigger at will.  Using pm_test may increase your chances:

    # echo 0 > /sys/module/printk/parameters/console_suspend
    # echo platform > /sys/power/pm_test
    # echo mem > /sys/power/state

To fix this, make sure the network interface is quietened during
suspend.
Signed-off-by: NGeert Uytterhoeven <geert+renesas@glider.be>
Reviewed-by: NFlorian Fainelli <f.fainelli@gmail.com>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 7095c973
......@@ -2595,6 +2595,11 @@ static int smsc911x_suspend(struct device *dev)
struct net_device *ndev = dev_get_drvdata(dev);
struct smsc911x_data *pdata = netdev_priv(ndev);
if (netif_running(ndev)) {
netif_stop_queue(ndev);
netif_device_detach(ndev);
}
/* enable wake on LAN, energy detection and the external PME
* signal. */
smsc911x_reg_write(pdata, PMT_CTRL,
......@@ -2628,7 +2633,15 @@ static int smsc911x_resume(struct device *dev)
while (!(smsc911x_reg_read(pdata, PMT_CTRL) & PMT_CTRL_READY_) && --to)
udelay(1000);
return (to == 0) ? -EIO : 0;
if (to == 0)
return -EIO;
if (netif_running(ndev)) {
netif_device_attach(ndev);
netif_start_queue(ndev);
}
return 0;
}
static const struct dev_pm_ops smsc911x_pm_ops = {
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!