netxen: reversed condition in netxen_nic_set_link_parameters()
My static checker complains that we are using "autoneg" without initializing it. The problem is the ->phy_read() condition is reversed so we only set this on error instead of success. Signed-off-by: NDan Carpenter <dan.carpenter@oracle.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>