提交 064d5cd1 编写于 作者: A Alban Bedel 提交者: Mark Brown

regulator: core: Fix the init of DT defined fixed regulators

When a regulator is defined using DT and it has a single voltage the
regulator init always tries to apply this voltage. However it fails if
the regulator isn't settable because it is using an internal low level
function. To overcome this we now first query the regulator and only
set it if needed.
Signed-off-by: NAlban Bedel <alban.bedel@avionic-design.de>
Signed-off-by: NMark Brown <broonie@linaro.org>
上级 fd482a3e
......@@ -844,13 +844,22 @@ static int machine_constraints_voltage(struct regulator_dev *rdev,
/* do we need to apply the constraint voltage */
if (rdev->constraints->apply_uV &&
rdev->constraints->min_uV == rdev->constraints->max_uV) {
ret = _regulator_do_set_voltage(rdev,
rdev->constraints->min_uV,
rdev->constraints->max_uV);
if (ret < 0) {
rdev_err(rdev, "failed to apply %duV constraint\n",
rdev->constraints->min_uV);
return ret;
int current_uV = _regulator_get_voltage(rdev);
if (current_uV < 0) {
rdev_err(rdev, "failed to get the current voltage\n");
return current_uV;
}
if (current_uV < rdev->constraints->min_uV ||
current_uV > rdev->constraints->max_uV) {
ret = _regulator_do_set_voltage(
rdev, rdev->constraints->min_uV,
rdev->constraints->max_uV);
if (ret < 0) {
rdev_err(rdev,
"failed to apply %duV constraint\n",
rdev->constraints->min_uV);
return ret;
}
}
}
......