-
由 Benjamin Tissoires 提交于
Since the inclusion of eGalax devices in 2.6.39, I've got some bug reports for 480d and other devices. The problem lies in the reports descriptors: eGalax supports both pen and fingers, and so the reports descriptors contained both. But hid-multitouch relies on them to detect the last item in each field to send the multitouch events. In 480d, the last item is not Y as it should but Pressure. That means that the fields are not aligned and X,Y are at 0,0 (the other touch coordinates of the report). With this patch, the detection is made only when the field ContactID has been detected inside the collection. There is still a problem with the detections of the range as stylus and fingers may not have the same min/max, but it's a start. Signed-off-by: NBenjamin Tissoires <benjamin.tissoires@enac.fr> Reviewed-by: NHenrik Rydberg <rydberg@euromail.se> Signed-off-by: NJiri Kosina <jkosina@suse.cz>
b84bd27f