由 Jon Hunter 提交于
Only OMAP1 devices use the omap_dm_timer_reset() and so require the omap_dm_timer_wait_for_reset() and __omap_dm_timer_reset() functions. Therefore combine these into a single function called omap_dm_timer_reset() and simplify the code. The omap_dm_timer_reset() function is now the only place that is using the omap_dm_timer structure member "sys_stat". Therefore, remove this member and just use the register offset definition to simplify and clean-up the code. The TISTAT register is only present on revision 1 timers and so check for this in the omap_dm_timer_reset() function. Please note that for OMAP1 devices, the TIOCP_CFG register does not have the clock-activity field and so when we reset the timer for an OMAP1 device we only need to configure the idle-mode field in the TIOCP_CFG register. Signed-off-by: NJon Hunter <jon-hunter@ti.com>