由 Tony Lindgren 提交于
Commit 5de85b9d ("PM / runtime: Re-init runtime PM states at probe error and driver unbind") introduced pm_runtime_reinit() that is used to reinitialize PM runtime after -EPROBE_DEFER. This allows shutting down the device after a failed probe. However, for drivers using pm_runtime_use_autosuspend() this can cause a state where suspend callback is never called after -EPROBE_DEFER. On the following device driver probe, hardware state is different from the PM runtime state causing omap_device to produce the following error: omap_device_enable() called from invalid state 1 And with omap_device and omap hardware being picky for PM, this will block any deeper idle states in hardware. The solution is to fix the drivers to follow the PM runtime documentation: 1. For sections of code that needs the device disabled, use pm_runtime_put_sync_suspend() if pm_runtime_set_autosuspend() has been set. 2. For driver exit code, use pm_runtime_dont_use_autosuspend() before pm_runtime_put_sync() if pm_runtime_use_autosuspend() has been set. Fixes: 5de85b9d ("PM / runtime: Re-init runtime PM states at probe error and driver unbind") Signed-off-by: NTony Lindgren <tony@atomide.com> Acked-by: NUlf Hansson <ulf.hansson@linaro.org> Signed-off-by: NWolfram Sang <wsa@the-dreams.de>
e6244dee