由 Hemant Pedanekar 提交于
If CONFIG_OMAP_32K_TIMER is not selected and dmtimer is used as clocksource, the timer stops counting once overflow occurs as it was not set in autoreload mode. This results into timekeeping failure: for example, 'sleep 1' at the shell after the timer counter overflow would hang. This patch sets up autoreload when starting the clocksource timer which fixes the above issue. Signed-off-by: NHemant Pedanekar <hemantp@ti.com> Signed-off-by: NTony Lindgren <tony@atomide.com>
e9d0b97e