由 Florian Fainelli 提交于
On newer and faster machines (Vortex X86DX) using the r6040 driver, it was noticed that the driver was returning an error during probing traced down to being the MDIO bus probing and the inability to complete a MDIO read operation in time. It turns out that the MDIO operations on these faster machines usually complete after ~2140 iterations which is bigger than 2048 (MAC_DEF_TIMEOUT) and results in spurious timeouts depending on the system load. Update r6040_phy_read() and r6040_phy_write() to include a 1 micro second delay in each busy-looping iteration of the loop which is a much safer operation than incrementing MAC_DEF_TIMEOUT. Reported-by: NNils Koehler <nils.koehler@ibt-interfaces.de> Reported-by: NDaniel Goertzen <daniel.goertzen@gmail.com> Signed-off-by: NFlorian Fainelli <florian@openwrt.org> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
4f8d9f3c