    regulator: s5m8767a: Support AP watchdog reset operation · c848bc85
    Sangbeom Kim 提交于
    The S5M8767A can't know status of ap reset.
    So, After AP watchdog reset, AP can't boot normally.
    
    Problem can be happened like below condition.
    - AP Bootable lowest voltage(vdd_arm): 0.9v
    - AP DVFS voltage table: 0.8v, 0.9v, 1.0v
    - During AP works on lowest voltage(0.8V), watchdog reset is asserted
    - AP can't boot, because vdd arm is still 0.8v
    
    Solution
    - Basic concept:
      After ap watchdog reset, GPIO configuration is changed by default value
    - S5M8767A has function of voltage control with gpio (8 levels with 3 gpios)
    - Set bootable voltage on level 0 -> can work with default gpio configuration
    - In the probing, Change voltage control level from level 0 to level 1
    - Execute normal dvfs operation on level 1
    - After watchdog reset, ap gpio is set by default value
    - PMIC operation mode is changed by ap reset (level1 -> level0)
    - Regardless of previous vdd_arm voltage, AP always can be booted.
    Signed-off-by: NSangbeom Kim <sbkim73@samsung.com>
    Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>