由 Andreas Gröger 提交于
In our department we are using some older Janz ICAN3-modules in our dekstop pcs. There we have slightly different carrier boards than the janz-cmodio supported in the kernel sources, called CAN-PCI2 with two submodules. But the pci configuration regions are identical. So extending the supported pci devices to the corresponding device ids is sufficient to get the drivers working. * The old ICAN3-modules with firmware 1.28 need more then 250ms for the restart after reset. I've increased the timeout to 500ms. * The janz_ican3 module uses the raw can services of the Janz-firmware, this means firmware must be ICANOS/2. Our ICAN3-modules are equipped with CAL/CANopen-firmware, so I must use the appropriate commands for the layer management services. Te driver detects the firmware after module reset and selects the commands matching the firmware. This affects the bus on/off-command (ican3_set_bus_state) and the configuration of the bittiming (ican3_set_bittiming). For better diagnostics the detected firmware string is presented as sysfs attribute (fwinfo). Signed-off-by: NAndreas Gröger <andreas24groeger@gmail.com> Signed-off-by: NMarc Kleine-Budde <mkl@pengutronix.de>
844e0edf