由 Madhuranath Iyengar 提交于
The FCP priority info was not being updated properly in certain situations. Here are the changes that needs to be done to take care of this issue: 1. No need to check fcport->state for FCS_UNCONFIGURED in qla24xx_update_fcport_fcp_prio(), since an invalid loop id check is already performed which is sufficient. 2. Add the missing qla24xx_update_fcport_fcp_prio() function call within qla2x00_update_fcport() function, so that the priority info is updated on every port addition or change. 3. Perform proper adapter types checking. 4. Other changes, associated with DEBUG/printk's and parameter passing. Signed-off-by: NSaurav Kashyap <saurav.kashyap@qlogic.com> Signed-off-by: NAndrew Vasquez <andrew.vasquez@qlogic.com> Signed-off-by: NGiridhar Malavali <giridhar.malavali@qlogic.com> Signed-off-by: NMadhuranath Iyengar <Madhu.Iyengar@qlogic.com> Signed-off-by: NJames Bottomley <James.Bottomley@suse.de>
21090cbe