-
由 Johannes Berg 提交于
When an interface is taken down while a scan is pending -- i.e. a scan request was accepted but not yet acted upon due to other work being in progress -- we currently do not properly cancel that scan and end up getting stuck. Fix this by doing better checks when an interface is taken down. Signed-off-by: NJohannes Berg <johannes@sipsolutions.net> Signed-off-by: NJohn W. Linville <linville@tuxdriver.com>
15db0b7f