# Generic thermal sysfs drivers configuration
#

menuconfig THERMAL
6
	tristate "Generic Thermal sysfs driver"
Z
Zhang Rui 已提交
7 8 9 10
	help
	  Generic Thermal Sysfs driver offers a generic mechanism for
	  thermal management. Usually it's made up of one or more thermal
	  zone and cooling device.
11
	  Each thermal zone contains its own temperature, trip points,
Z
Zhang Rui 已提交
12 13
	  cooling devices.
	  All platforms with ACPI thermal support can use this driver.
14
	  If you want this support, you should say Y or M here.
15

Z
Zhang Rui 已提交
16 17
if THERMAL

18
config THERMAL_HWMON
19
	bool
20
	prompt "Expose thermal sensors as hwmon device"
21
	depends on HWMON=y || HWMON=THERMAL
22
	default y
23 24 25 26 27 28 29 30
	help
	  In case a sensor is registered with the thermal
	  framework, this option will also register it
	  as a hwmon. The sensor will then have the common
	  hwmon sysfs interface.

	  Say 'Y' here if you want all thermal sensors to
	  have hwmon sysfs interface too.
31

Z
Zhang Rui 已提交
32 33 34 35 36 37 38 39 40
choice
	prompt "Default Thermal governor"
	default THERMAL_DEFAULT_GOV_STEP_WISE
	help
	  This option sets which thermal governor shall be loaded at
	  startup. If in doubt, select 'step_wise'.

config THERMAL_DEFAULT_GOV_STEP_WISE
	bool "step_wise"
41
	select THERMAL_GOV_STEP_WISE
Z
Zhang Rui 已提交
42 43 44 45 46 47
	help
	  Use the step_wise governor as default. This throttles the
	  devices one step at a time.

config THERMAL_DEFAULT_GOV_FAIR_SHARE
	bool "fair_share"
48
	select THERMAL_GOV_FAIR_SHARE
Z
Zhang Rui 已提交
49 50 51 52 53 54 55
	help
	  Use the fair_share governor as default. This throttles the
	  devices based on their 'contribution' to a zone. The
	  contribution should be provided through platform data.

config THERMAL_DEFAULT_GOV_USER_SPACE
	bool "user_space"
56
	select THERMAL_GOV_USER_SPACE
Z
Zhang Rui 已提交
57 58
	help
	  Select this if you want to let the user space manage the
59
	  platform thermals.
Z
Zhang Rui 已提交
60 61 62

endchoice

63
config THERMAL_GOV_FAIR_SHARE
Z
Zhang Rui 已提交
64 65 66 67
	bool "Fair-share thermal governor"
	help
	  Enable this to manage platform thermals using fair-share governor.

68
config THERMAL_GOV_STEP_WISE
Z
Zhang Rui 已提交
69 70 71
	bool "Step_wise thermal governor"
	help
	  Enable this to manage platform thermals using a simple linear
L
Luka Perkov 已提交
72
	  governor.
Z
Zhang Rui 已提交
73

74
config THERMAL_GOV_USER_SPACE
Z
Zhang Rui 已提交
75 76 77 78
	bool "User_space thermal governor"
	help
	  Enable this to let the user space manage the platform thermals.

79
config CPU_THERMAL
80
	bool "generic cpu cooling support"
Z
Zhang Rui 已提交
81
	depends on CPU_FREQ
82
	select CPU_FREQ_TABLE
83 84
	help
	  This implements the generic cpu cooling mechanism through frequency
85 86
	  reduction. An ACPI version of this already exists
	  (drivers/acpi/processor_thermal.c).
87 88
	  This will be useful for platforms using the generic thermal interface
	  and not the ACPI interface.
89

90 91
	  If you want this support, you should say Y here.

92 93 94 95 96 97 98 99
config THERMAL_EMULATION
	bool "Thermal emulation mode support"
	help
	  Enable this option to make a emul_temp sysfs node in thermal zone
	  directory to support temperature emulation. With emulation sysfs node,
	  user can manually input temperature and test the different trip
	  threshold behaviour for simulation purpose.

100 101 102 103
	  WARNING: Be careful while enabling this option on production systems,
	  because userland can easily disable the thermal policy by simply
	  flooding this sysfs node with low temperature values.

104 105 106 107 108 109 110 111 112 113 114
config IMX_THERMAL
	tristate "Temperature sensor driver for Freescale i.MX SoCs"
	depends on CPU_THERMAL
	depends on MFD_SYSCON
	depends on OF
	help
	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
	  It supports one critical trip point and one passive trip point.  The
	  cpufreq is used as the cooling device to throttle CPUs when the
	  passive trip is crossed.

115 116 117
config SPEAR_THERMAL
	bool "SPEAr thermal sensor driver"
	depends on PLAT_SPEAR
118
	depends on OF
119 120
	help
	  Enable this to plug the SPEAr thermal sensor driver into the Linux
L
Luka Perkov 已提交
121
	  thermal framework.
122 123 124 125 126 127

config RCAR_THERMAL
	tristate "Renesas R-Car thermal driver"
	depends on ARCH_SHMOBILE
	help
	  Enable this to plug the R-Car thermal sensor driver into the Linux
L
Luka Perkov 已提交
128
	  thermal framework.
129

130 131 132 133 134 135 136 137
config KIRKWOOD_THERMAL
	tristate "Temperature sensor on Marvell Kirkwood SoCs"
	depends on ARCH_KIRKWOOD
	depends on OF
	help
	  Support for the Kirkwood thermal sensor driver into the Linux thermal
	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.

138 139 140 141 142 143 144 145
config DOVE_THERMAL
	tristate "Temperature sensor on Marvell Dove SoCs"
	depends on ARCH_DOVE
	depends on OF
	help
	  Support for the Dove thermal sensor driver in the Linux thermal
	  framework.

146 147 148 149 150 151 152 153 154 155
config DB8500_THERMAL
	bool "DB8500 thermal management"
	depends on ARCH_U8500
	default y
	help
	  Adds DB8500 thermal management implementation according to the thermal
	  management framework. A thermal zone with several trip points will be
	  created. Cooling devices can be bound to the trip points to cool this
	  thermal zone if trip points reached.

156 157 158 159 160 161 162 163
config ARMADA_THERMAL
	tristate "Armada 370/XP thermal management"
	depends on ARCH_MVEBU
	depends on OF
	help
	  Enable this option if you want to have support for thermal management
	  controller present in Armada 370 and Armada XP SoC.

164 165 166 167 168 169 170 171 172 173
config DB8500_CPUFREQ_COOLING
	tristate "DB8500 cpufreq cooling"
	depends on ARCH_U8500
	depends on CPU_THERMAL
	default y
	help
	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
	  bound to thermal zone trip points. When a trip point reached, the
	  bound cpufreq cooling device turns active to set CPU frequency low to
	  cool down the CPU.
174

175 176 177 178 179 180 181 182 183 184
config INTEL_POWERCLAMP
	tristate "Intel PowerClamp idle injection driver"
	depends on THERMAL
	depends on X86
	depends on CPU_SUP_INTEL
	help
	  Enable this to enable Intel PowerClamp idle injection driver. This
	  enforce idle time which results in more package C-state residency. The
	  user interface is exposed via generic thermal framework.

185 186
config X86_PKG_TEMP_THERMAL
	tristate "X86 package temperature thermal driver"
187
	depends on X86_THERMAL_VECTOR
188 189 190 191 192 193 194 195
	select THERMAL_GOV_USER_SPACE
	default m
	help
	  Enable this to register CPU digital sensor for package temperature as
	  thermal zone. Each package will have its own thermal zone. There are
	  two trip points which can be set by user to get notifications via thermal
	  notification methods.

196 197 198
menu "Texas Instruments thermal drivers"
source "drivers/thermal/ti-soc-thermal/Kconfig"
endmenu
199

200 201 202 203 204
menu "Samsung thermal drivers"
depends on PLAT_SAMSUNG
source "drivers/thermal/samsung/Kconfig"
endmenu

Z
Zhang Rui 已提交
205
endif