提交 b2887c43 编写于 作者: J Jean-Christophe DUBOIS 提交者: Andrzej Zaborowski

hw/arm_sysctl: Fix RESETCTL for realview-pb-a8 and -pbx-a9

Depending on the considered baseboard the bit used to
reset the platform is different.

Here is the list of considered Realview/Versatile platforms:

Realview/Versatile AB for ARM926EJ-S: BOARD_ID = 0x100 = BOARD_ID_PB9
http://infocenter.arm.com/help/topic/com.arm.doc.dui0225d/CACCIFGI.html

RealView Emulation Baseboard: BOARD_ID = 0x140 = BOARD_ID_EB
No reset register

RealView PB for Cortex-A8: BOARD_ID = 0x178 = BOARD_ID_PBA8
http://infocenter.arm.com/help/topic/com.arm.doc.dui0417d/BBACIGAD.html

RealView PB for Cortex-A9: BOARD_ID = 0x182 = BOARD_ID_PBX
http://infocenter.arm.com/help/topic/com.arm.doc.dui0440b/CACCHBFB.html

Motherboard Express =C2=B5ATX: BOARD_ID = 0x190 = BOARD_ID_VEXPRESS
No reset register
Signed-off-by: NJean-Christophe DUBOIS <jcd@tribudubois.net>
Reviewed-by: NPeter Maydell <peter.maydell@linaro.org>
Signed-off-by: NAndrzej Zaborowski <andrew.zaborowski@intel.com>
上级 7c64d297
......@@ -231,15 +231,30 @@ static void arm_sysctl_write(void *opaque, target_phys_addr_t offset,
s->nvflags &= ~val;
break;
case 0x40: /* RESETCTL */
if (board_id(s) == BOARD_ID_VEXPRESS) {
switch (board_id(s)) {
case BOARD_ID_PB926:
if (s->lockval == LOCK_VALUE) {
s->resetlevel = val;
if (val & 0x100) {
qemu_system_reset_request();
}
}
break;
case BOARD_ID_PBX:
case BOARD_ID_PBA8:
if (s->lockval == LOCK_VALUE) {
s->resetlevel = val;
if (val & 0x04) {
qemu_system_reset_request();
}
}
break;
case BOARD_ID_VEXPRESS:
case BOARD_ID_EB:
default:
/* reserved: RAZ/WI */
break;
}
if (s->lockval == LOCK_VALUE) {
s->resetlevel = val;
if (val & 0x100)
qemu_system_reset_request ();
}
break;
case 0x44: /* PCICTL */
/* nothing to do. */
......