hw/arm/iotkit: Fix IRQ number for timer1
A cut-and-paste error meant we were incorrectly wiring up the timer1 IRQ to IRQ3. IRQ3 is the interrupt for timer0 -- move timer0 to IRQ4 where it belongs. Signed-off-by: NPeter Maydell <peter.maydell@linaro.org> Reviewed-by: NPhilippe Mathieu-Daudé <f4bug@amsat.org> Message-id: 20180727113854.20283-3-peter.maydell@linaro.org