提交 2e550230 编写于 作者: J Janosch Frank 提交者: Michael Roth

s390x: Return specification exception for unimplemented diag 308 subcodes

The architecture specifies specification exceptions for all
unavailable subcodes.

The presence of subcodes is indicated by checking some query subcode.
For example 6 will indicate that 3-6 are available. So future systems
might call new subcodes to check for new features. This should not
trigger a hw error, instead we return the architectured specification
exception.
Signed-off-by: NJanosch Frank <frankja@linux.ibm.com>
Cc: qemu-stable@nongnu.org
Message-Id: <20190111113657.66195-3-frankja@linux.ibm.com>
Reviewed-by: NChristian Borntraeger <borntraeger@de.ibm.com>
Reviewed-by: NDavid Hildenbrand <david@redhat.com>
Signed-off-by: NCornelia Huck <cohuck@redhat.com>
(cherry picked from commit 37dbd1f4)
Signed-off-by: NMichael Roth <mdroth@linux.vnet.ibm.com>
上级 8ec7368c
......@@ -130,7 +130,7 @@ out:
}
return;
default:
hw_error("Unhandled diag308 subcode %" PRIx64, subcode);
s390_program_interrupt(env, PGM_SPECIFICATION, ILEN_AUTO, ra);
break;
}
}