• C
    iotests: make 083 specific to raw · d98205c5
    Cleber Rosa 提交于
    While testing the Python 3 changes which touch the 083 test, I noticed
    that it would fail with qcow2.  Expanding the testing, I noticed it
    had nothing to do with the Python 3 changes, and in fact, it would not
    pass on anything but raw:
    
     raw: pass
     bochs: not generic
     cloop: not generic
     parallels: fail
     qcow: fail
     qcow2: fail
     qed: fail
     vdi: fail
     vhdx: fail
     vmdk: fail
     vpc: fail
     luks: fail
    
    The errors are a mixture I/O and "image not in xxx format", such as:
    
      === Check disconnect before data ===
    
      Unexpected end-of-file before all bytes were read
     -read failed: Input/output error
     +can't open device nbd+tcp://127.0.0.1:PORT/foo: Could not open 'nbd://127.0.0.1:PORT/foo': Input/output error
    
      === Check disconnect after data ===
    
     -read 512/512 bytes at offset 0
     -512 bytes, X ops; XX:XX:XX.X (XXX YYY/sec and XXX ops/sec)
     +can't open device nbd+tcp://127.0.0.1:PORT/foo: Image not in qcow format
    
    I'm not aware if there's a quick fix, so, for the time being, it looks
    like the honest approach is to make the test known to work on raw
    only.
    Signed-off-by: NCleber Rosa <crosa@redhat.com>
    Signed-off-by: NKevin Wolf <kwolf@redhat.com>